# QUADAS-3 Assessment Guide Quality Assessment of Diagnostic Accuracy Studies, version 3 — **the current recommended version**. Version: QUADAS-3 tool v1.2 — 6 phases, 4 domains, **20 signalling questions** (4 / 4 / 8 / 4). Source: Whiting PF, Tomlinson E, Rutjes AWS, Davenport C, Yang B, Westwood M, et al. QUADAS-3: a revised tool for the quality assessment of diagnostic test accuracy studies. *Ann Intern Med* 2026;179(4):548-555 (DOI 10.7326/ANNALS-25-02104). The tool itself, the Explanation & Elaboration report and an introductory video are distributed by the QUADAS group at https://www.bristol.ac.uk/population-health-sciences/projects/quadas/quadas-3/ Explanation & Elaboration: Davenport CF, Rutjes AWS, Mallett S, Tomlinson E, Yang B, et al. QUADAS-3 explanation and elaboration: guidance for quality assessment of diagnostic test accuracy studies. *Ann Intern Med* 2026;179(4):e2504943 (DOI 10.7326/ANNALS-25-04943). Resource site: **www.quadas.info** (the older www.quadas.org no longer resolves). > **Fidelity and licence.** QUADAS-3 is published in *Annals of Internal Medicine* (© American > College of Physicians) under **no open licence** — Crossref returns only ACP's text-and-data-mining > policy. The descriptions below state what each question asks **in our own words** rather than > reproducing the published wording. **Complete the official QUADAS-3 form (`QUADAS-3 1.2.docx`) > from the page above for any assessment you report, and read the E&E report before using it.** > > Verification: the six phases and when each is completed, the four domains, all 20 signalling > questions, the response options, the domain-level rule, which domains carry an applicability > judgement, and the overall-judgement rules were compared against **the official tool document > v1.2** distributed by the QUADAS group. All matched. The *Using QUADAS-C with QUADAS-3*, > *Tailoring* and *no "moderate" grade* sections below are taken from the **Explanation and > Elaboration paper**, read directly. ## QUADAS-3 supersedes QUADAS-2 The QUADAS group states QUADAS-3 "is the current version of QUADAS and the tool that we recommend." For a new review, use this file. `QUADAS2.md` documents the 2011 tool, which is what most published reviews used and what you will still be reading in them. What changed, in the group's own framing: | | QUADAS-2 | QUADAS-3 | |---|---|---| | Unit of assessment | the **study** | **each set of accuracy estimates** | | Comparator for judging | implicit | an explicit **ideal test accuracy trial**, defined per synthesis question | | Synthesis questions | one, implicit | **multiple, defined up front** | | Overall judgment | none | **a formal phase (6)** | | Phases | 4 | **6** | | Domains | Patient Selection, Index Test, Reference Standard, Flow and Timing | **Participants, Index Test, Target Condition, Analysis** | | Signalling questions | 10 (3/2/2/3) | **20 (4/4/8/4)** | | Third judgement level | "unclear" | **"insufficient information" (II)** | Note the domain rename: QUADAS-2's *Flow and Timing* is gone. Timing moved into **Target Condition** (the index-test-to-reference-standard interval), and participant exclusions, missing data and the unit of analysis moved into the new **Analysis** domain. **Comparative accuracy reviews**: the group recommends using **QUADAS-C in addition to QUADAS-3** (`QUADAS_C.md`). QUADAS-C was written against QUADAS-2 and needs adaptation — see the next section. ## Using QUADAS-C with QUADAS-3 For comparative accuracy studies — where two or more index tests are compared — the guideline says to use **QUADAS-C alongside QUADAS-3**, because such studies carry additional sources of bias (confounding between tests, and interference of one test with another). QUADAS-C was written as an extension of QUADAS-2, so it needs adapting. **An updated QUADAS-C is in development**; what follows are the E&E's own *preliminary* modifications, not a finished tool. ### What you assess The unit is a **comparative measure** — for example the difference in sensitivity or in specificity between two tests. Most primary studies report only the separate estimate for each index test, so **you will usually have to compute the comparative measure yourself.** Specify which estimate a QUADAS-C assessment refers to, exactly as you do in QUADAS-3 phase 4. ### Domains are renamed onto QUADAS-3's | QUADAS-C (as published) | becomes | |---|---| | Patient Selection | **Participants** | | Index Test | Index Test *(unchanged)* | | Reference Standard | **Target Condition** | | Flow and Timing | **Analysis** | ### Three signalling questions change (E&E Table 8) | QUADAS-C question | Change | |---|---| | **C3.2** Did the reference standard avoid incorporating any of the index tests? | **Removed** — it overlaps QUADAS-3 item 3.4 | | **C4.2** Was there an appropriate interval between the index tests? | **Moved to domain 2** (Index Test) | | **C4.3** Was the same reference standard used for all index tests? | **Moved to domain 3** (Target Condition) | Everything else carries over unchanged. ### Answers and judgements follow QUADAS-3 Signalling questions take **Y / PY / PN / N / NI**; each domain is judged **low / high / insufficient information**. The overall judgement for the comparative estimate: - **low** if all domains are low - **high** if at least one domain is high - **insufficient information** if at least one domain is II and none is high ## The six phases | Phase | What | How often | |---|---|---| | 1 | State the systematic review synthesis question(s) | once per review | | 2 | Define the **ideal test accuracy trial** for each synthesis question | once per review | | 3 | Draw a flow diagram | once per study | | 4 | Identify which accuracy estimates to assess | once per study | | 5 | Assess risk of bias and applicability | for each selected estimate | | 6 | Overall judgment | for each selected estimate | Phases 1 and 2 are review-level and **belong in the review protocol**. Phases 3–4 are study-level. Phases 5–6 run once per selected set of estimates. **Phase 1** — a review may address more than one synthesis question. Specify each with its population, index test(s) and target condition, and pre-specify them in the protocol. **Phase 2** — the ideal test accuracy trial is the study that would answer the synthesis question with minimum bias and maximum applicability. Define it per question across: objective, participants, index test(s), definition of the target condition, and analysis. Every later judgement is made **against this trial**, not against an unstated ideal. **Phase 4** — a single primary study usually yields several two-by-two tables. Assess only the estimates relevant to a synthesis question. Record, for each: the synthesis question, the numerical result, participants, index test and threshold, target condition, reference standard, unit of analysis, and the analysis method. After the first estimate, **only the domains whose characteristics differ between estimates need reassessing**. ## Phase 5 — signalling questions Signalling questions: **Y / PY / PN / N / NI**. Domain risk-of-bias judgement: **low / high / insufficient information (II)**. ### Domain 1: Participants (4) | # | Signalling question | |---|---------------------| | 1.1 | Was a single-gate design used? | | 1.2 | Were participants prospectively enrolled? | | 1.3 | Was a consecutive or random sample of participants included? | | 1.4 | Is the study group a representative sample of the intended-use population? | *Applicability*: does the included population match the ideal trial's? Participants who dropped out or were excluded because they did not receive the index test or the reference standard belong in **Domain 4 (Analysis)**, not here. ### Domain 2: Index Test (4) | # | Signalling question | |---|---------------------| | 2.1 | Was the index test conducted and interpreted according to the recommended instructions? | | 2.2 | Were the index test results interpreted without knowledge of the reference standard results? | | 2.3 | Were the index test results interpreted with the same information that would be available when the test is used in practice? | | 2.4 | If an index test threshold was used, was it standard or pre-specified? | *Applicability*: does the index test, its conduct and its interpretation match the ideal trial's? 2.3 is new relative to QUADAS-2 and cuts both ways — a reader given **more** information than they would have in practice is as much a problem as one given less. ### Domain 3: Target Condition (8) | # | Signalling question | |---|---------------------| | 3.1 | Does the reference standard adequately identify those with and without the target condition? | | 3.2 | Was the target condition assessed in all participants? | | 3.3 | Was the target condition assessed in the same way in all participants? | | 3.4 | Did the reference standard avoid incorporating the index test? | | 3.5 | Was the reference standard conducted and interpreted according to the recommended instructions? | | 3.6 | Were the reference standard results interpreted without knowledge of the index test results? | | 3.7 | If a reference standard threshold was used, was it standard or pre-specified? | | 3.8 | Was there an appropriate time interval between index test and reference standard? | *Applicability*: does the target condition as defined by the reference standard match the ideal trial's? This domain absorbs QUADAS-2's Reference Standard domain **and** its verification and timing questions. 3.2 and 3.3 are partial and differential verification; 3.8 is the interval that used to sit in Flow and Timing. ### Domain 4: Analysis (4) | # | Signalling question | |---|---------------------| | 4.1 | Were all participants included in the analysis? | | 4.2 | Were missing data handled appropriately? | | 4.3 | Does the unit of analysis match the ideal test accuracy trial? | | 4.4 | Were the estimates of sensitivity and specificity calculated appropriately? | **No applicability judgement** — applicability is assessed for the first three domains only. 4.3 is where a lesion-level or sample-level analysis meets a participant-level synthesis question. That mismatch had no home in QUADAS-2. ## Judgement rules **Domain level.** If all signalling questions in a domain are answered *yes* or *probably yes*, risk of bias can be judged **low**. A *no* or *probably no* **flags potential** for bias — it does not settle it. Reviewers then apply their judgement and their review-specific guidance to decide whether the issue is likely to have influenced the accuracy estimates. > **A study can still be at low risk of bias with one or more signalling questions answered "no."** > The tool says this explicitly. Do not implement "any No → High" as a rule; that replaces the > judgement the tool asks for. Use **insufficient information** only when too little is reported to permit a judgement. It is not a middle rating between low and high. **Overall (phase 6)**, per estimate, done separately for risk of bias and for applicability: - any domain **high** → overall **high** - all domains **low** → overall **low** - any domain **insufficient information** and none high → overall **insufficient information** Record a rationale naming the major limitations behind the overall judgement. **Do not add a "moderate" grade.** Reviewers sometimes want one, to separate a study that is high risk in a single domain from one that is high risk in several. The E&E says plainly that the authors *do not support* this: if an estimate is high risk for one domain, it is high risk, whatever the other domains say. ## Tailoring the tool to your review Phase 2's tailoring is the step most often skipped, and the E&E is specific about it. - Do it **at the protocol stage, alongside phases 1 and 2** — not when you reach the studies. - Write review-specific guidance on how to answer each signalling question, adapting the general guidance tables. Publish it as a web appendix so the application is auditable. - Draw on **both clinical and methodological** expertise in the review area. - **Do not remove signalling questions.** Keep them even when they cannot bite: if two-gate designs were excluded, every study answers "yes" to 1.1, and recording that shows the issue was considered. Deleting the question hides that. - If you add a question, it must: address **one** issue only; concern **risk of bias, not reporting quality**; and be **factual**, phrased so that "yes"/"probably yes" means bias is absent. ## When to Use - Systematic reviews assessing the accuracy of tests used for **diagnosis, screening or staging** - New reviews — QUADAS-3 is the current recommended version - Alongside **QUADAS-C** when the review compares the accuracy of two or more index tests - Read the **Explanation & Elaboration report** before first use, and tailor the signalling questions and their guidance to your review (that tailoring is the step most often skipped) - Not for prediction models (PROBAST), non-randomised intervention studies (ROBINS-I), or randomised trials (RoB 2)