# SPIRIT-AI Checklist **Standard Protocol Items: Recommendations for Interventional Trials -- Artificial Intelligence Extension** Version: SPIRIT-AI 2020 (extends SPIRIT 2013) Source: https://www.consort-spirit.org · EQUATOR Network Reference: Cruz Rivera S, Liu X, Chan AW, et al. Nat Med 2020;26(9):1351-1363. doi:10.1038/s41591-020-1037-7 (CC BY 4.0) > Educational summary, authored in our own words from the CC BY 4.0 source. Use the official > SPIRIT-AI checklist for a submission-ready form and cite Cruz Rivera et al. 2020. > **Verified against the published statement.** All 15 AI items were enumerated from the article's > own checklist table via the PMC XML and compared label-by-label: **12 Extensions and > 3 Elaborations**, matching exactly with no item missing and none invented. > **Extension vs Elaboration — the statement distinguishes them, and it matters.** An **Extension** > is a *new* reporting requirement that SPIRIT 2013 does not contain. An **Elaboration** clarifies how an > existing SPIRIT 2013 item applies when the intervention involves AI; the requirement already existed, > the guidance is what is new. Both are assessed, but only the Extensions are additional obligations — > do not report an Elaboration as though the base instrument had been silent on it. Elaborations are > marked **(E)** below. ## Naming and scope (read first) - SPIRIT-AI is an **extension** of **SPIRIT 2013**, for **protocols** of randomized clinical trials of interventions that **include an AI/ML component**. Apply **both**: every base SPIRIT 2013 item plus the AI-specific items below; name and cite both instruments (manuscript-style-classical §14). - It is the **protocol** counterpart of **CONSORT-AI** (completed-trial reports). For a finished trial report use CONSORT-AI. - The AI items elaborate existing SPIRIT items (numbered to match); assess each alongside its parent. ## AI-specific extension items Status each PRESENT / PARTIAL / MISSING / N/A. ### Administrative Information | # | Item | Description (intent) | |---|------|----------------------| | 1 (i) **(E)** | AI identification | State in the title that the intervention involves AI/ML and specify the type of model. | | 1 (ii) **(E)** | Intended use | State the intended use of the AI intervention. | ### Introduction — Background and rationale | # | Item | Description (intent) | |---|------|----------------------| | 6a (i) | Role in pathway | Explain the intended use of the AI intervention within the clinical pathway, including its purpose and the intended users. | | 6a (ii) | Prior validation | Describe any pre-existing evidence for the AI intervention (e.g., prior validation studies). | ### Methods — Participants, interventions, outcomes | # | Item | Description (intent) | |---|------|----------------------| | 9 | Setting integration | Describe the onsite and offsite requirements needed to integrate the AI intervention into the trial setting. | | 10 (i) **(E)** | Participant eligibility | State the participant-level inclusion and exclusion criteria. | | 10 (ii) | Input-data eligibility | State the inclusion and exclusion criteria at the level of the **input data**. | | 11a (i) | Algorithm version | Specify which version of the AI algorithm will be used. | | 11a (ii) | Input acquisition | Specify how the input data will be acquired and selected. | | 11a (iii) | Poor-quality input | Specify how poor-quality or unavailable input data will be assessed and handled. | | 11a (iv) | Human–AI interaction | Specify any human–AI interaction in handling input data and the expertise required of the user. | | 11a (v) | AI output | Specify the output of the AI intervention. | | 11a (vi) | Output to decision | Explain how the AI intervention's outputs will contribute to decision-making or other elements of clinical practice. | ### Methods — Monitoring | # | Item | Description (intent) | |---|------|----------------------| | 22 | Error analysis plan | Specify the plans to identify and analyze performance errors, and any planned mitigation. | ### Ethics and Dissemination | # | Item | Description (intent) | |---|------|----------------------| | 29 | Code/intervention access | State whether and how the AI intervention and/or its code can be accessed, including any restrictions. | --- ## Notes for Assessors - Apply SPIRIT-AI **with** all base SPIRIT 2013 items — the AI items do not replace them. - **Algorithm version (11a (i))** and an explicit **error-analysis plan (22)** are the protocol-stage commitments that make the eventual CONSORT-AI report verifiable; mark MISSING if absent. - **Input-data eligibility (10 (ii))** is distinct from participant eligibility — a common gap. - **Setting integration (9)** and **human–AI interaction (11a (iv))** define whether the protocol evaluates the AI as it will actually be used; vague phrasing is PARTIAL. - Use **CONSORT-AI** for the completed-trial report; SPIRIT-AI is for the protocol.