{ "containers": { "cna": { "affected": [ { "product": "n/a", "vendor": "n/a", "versions": [ { "status": "affected", "version": "n/a" } ] } ], "datePublic": "2010-07-16T00:00:00.000Z", "descriptions": [ { "lang": "en", "value": "Siemens Simatic WinCC and PCS 7 SCADA system uses a hard-coded password, which allows local users to access a back-end database and gain privileges, as demonstrated in the wild in July 2010 by the Stuxnet worm, a different vulnerability than CVE-2010-2568." } ], "problemTypes": [ { "descriptions": [ { "description": "n/a", "lang": "en", "type": "text" } ] } ], "providerMetadata": { "dateUpdated": "2017-08-16T14:57:01.000Z", "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "shortName": "mitre" }, "references": [ { "name": "simatic-wincc-default-password(60587)", "tags": [ "vdb-entry", "x_refsource_XF" ], "url": "https://exchange.xforce.ibmcloud.com/vulnerabilities/60587" }, { "tags": [ "x_refsource_MISC" ], "url": "http://infoworld.com/d/security-central/siemens-warns-users-dont-change-passwords-after-worm-attack-915?sourcefssr" }, { "tags": [ "x_refsource_CONFIRM" ], "url": "http://support.automation.siemens.com/WW/llisapi.dll?func=cslib.csinfo&lang=en&objid=43876783&caller=viewhttp://support.automation.siemens.com/WW/llisapi.dll?func=cslib.csinfo&lang=en&objid=43876783&c" }, { "tags": [ "x_refsource_MISC" ], "url": "http://ics-cert.us-cert.gov/advisories/ICSA-12-205-01" }, { "tags": [ "x_refsource_MISC" ], "url": "http://www.f-secure.com/weblog/archives/00001987.html" }, { "tags": [ "x_refsource_MISC" ], "url": "http://www.automation.siemens.com/forum/guests/PostShow.aspx?PostID=16127&16127&Language=en&PageIndex=1" }, { "name": "ADV-2010-1893", "tags": [ "vdb-entry", "x_refsource_VUPEN" ], "url": "http://www.vupen.com/english/advisories/2010/1893" }, { "name": "40682", "tags": [ "third-party-advisory", "x_refsource_SECUNIA" ], "url": "http://secunia.com/advisories/40682" }, { "tags": [ "x_refsource_MISC" ], "url": "http://krebsonsecurity.com/2010/07/experts-warn-of-new-windows-shortcut-flaw/" }, { "tags": [ "x_refsource_CONFIRM" ], "url": "http://www.sea.siemens.com/us/News/Industrial/Pages/WinCC_Update.aspx" }, { "name": "41753", "tags": [ "vdb-entry", "x_refsource_BID" ], "url": "http://www.securityfocus.com/bid/41753" }, { "tags": [ "x_refsource_MISC" ], "url": "http://infoworld.com/d/security-central/new-weaponized-virus-targets-industrial-secrets-725" }, { "tags": [ "x_refsource_MISC" ], "url": "http://www.wilderssecurity.com/showpost.php?p=1712134&postcount=22" }, { "tags": [ "x_refsource_MISC" ], "url": "http://www.wired.com/threatlevel/2010/07/siemens-scada/" } ], "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "cve@mitre.org", "ID": "CVE-2010-2772", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "n/a", "version": { "version_data": [ { "version_value": "n/a" } ] } } ] }, "vendor_name": "n/a" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "Siemens Simatic WinCC and PCS 7 SCADA system uses a hard-coded password, which allows local users to access a back-end database and gain privileges, as demonstrated in the wild in July 2010 by the Stuxnet worm, a different vulnerability than CVE-2010-2568." } ] }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "n/a" } ] } ] }, "references": { "reference_data": [ { "name": "simatic-wincc-default-password(60587)", "refsource": "XF", "url": "https://exchange.xforce.ibmcloud.com/vulnerabilities/60587" }, { "name": "http://infoworld.com/d/security-central/siemens-warns-users-dont-change-passwords-after-worm-attack-915?sourcefssr", "refsource": "MISC", "url": "http://infoworld.com/d/security-central/siemens-warns-users-dont-change-passwords-after-worm-attack-915?sourcefssr" }, { "name": "http://support.automation.siemens.com/WW/llisapi.dll?func=cslib.csinfo&lang=en&objid=43876783&caller=viewhttp://support.automation.siemens.com/WW/llisapi.dll?func=cslib.csinfo&lang=en&objid=43876783&c", "refsource": "CONFIRM", "url": "http://support.automation.siemens.com/WW/llisapi.dll?func=cslib.csinfo&lang=en&objid=43876783&caller=viewhttp://support.automation.siemens.com/WW/llisapi.dll?func=cslib.csinfo&lang=en&objid=43876783&c" }, { "name": "http://ics-cert.us-cert.gov/advisories/ICSA-12-205-01", "refsource": "MISC", "url": "http://ics-cert.us-cert.gov/advisories/ICSA-12-205-01" }, { "name": "http://www.f-secure.com/weblog/archives/00001987.html", "refsource": "MISC", "url": "http://www.f-secure.com/weblog/archives/00001987.html" }, { "name": "http://www.automation.siemens.com/forum/guests/PostShow.aspx?PostID=16127&16127&Language=en&PageIndex=1", "refsource": "MISC", "url": "http://www.automation.siemens.com/forum/guests/PostShow.aspx?PostID=16127&16127&Language=en&PageIndex=1" }, { "name": "ADV-2010-1893", "refsource": "VUPEN", "url": "http://www.vupen.com/english/advisories/2010/1893" }, { "name": "40682", "refsource": "SECUNIA", "url": "http://secunia.com/advisories/40682" }, { "name": "http://krebsonsecurity.com/2010/07/experts-warn-of-new-windows-shortcut-flaw/", "refsource": "MISC", "url": "http://krebsonsecurity.com/2010/07/experts-warn-of-new-windows-shortcut-flaw/" }, { "name": "http://www.sea.siemens.com/us/News/Industrial/Pages/WinCC_Update.aspx", "refsource": "CONFIRM", "url": "http://www.sea.siemens.com/us/News/Industrial/Pages/WinCC_Update.aspx" }, { "name": "41753", "refsource": "BID", "url": "http://www.securityfocus.com/bid/41753" }, { "name": "http://infoworld.com/d/security-central/new-weaponized-virus-targets-industrial-secrets-725", "refsource": "MISC", "url": "http://infoworld.com/d/security-central/new-weaponized-virus-targets-industrial-secrets-725" }, { "name": "http://www.wilderssecurity.com/showpost.php?p=1712134&postcount=22", "refsource": "MISC", "url": "http://www.wilderssecurity.com/showpost.php?p=1712134&postcount=22" }, { "name": "http://www.wired.com/threatlevel/2010/07/siemens-scada/", "refsource": "MISC", "url": "http://www.wired.com/threatlevel/2010/07/siemens-scada/" } ] } } }, "adp": [ { "providerMetadata": { "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE", "dateUpdated": "2024-08-07T02:46:48.161Z" }, "title": "CVE Program Container", "references": [ { "name": "simatic-wincc-default-password(60587)", "tags": [ "vdb-entry", "x_refsource_XF", "x_transferred" ], "url": "https://exchange.xforce.ibmcloud.com/vulnerabilities/60587" }, { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "http://infoworld.com/d/security-central/siemens-warns-users-dont-change-passwords-after-worm-attack-915?sourcefssr" }, { "tags": [ "x_refsource_CONFIRM", "x_transferred" ], "url": "http://support.automation.siemens.com/WW/llisapi.dll?func=cslib.csinfo&lang=en&objid=43876783&caller=viewhttp://support.automation.siemens.com/WW/llisapi.dll?func=cslib.csinfo&lang=en&objid=43876783&c" }, { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "http://ics-cert.us-cert.gov/advisories/ICSA-12-205-01" }, { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "http://www.f-secure.com/weblog/archives/00001987.html" }, { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "http://www.automation.siemens.com/forum/guests/PostShow.aspx?PostID=16127&16127&Language=en&PageIndex=1" }, { "name": "ADV-2010-1893", "tags": [ "vdb-entry", "x_refsource_VUPEN", "x_transferred" ], "url": "http://www.vupen.com/english/advisories/2010/1893" }, { "name": "40682", "tags": [ "third-party-advisory", "x_refsource_SECUNIA", "x_transferred" ], "url": "http://secunia.com/advisories/40682" }, { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "http://krebsonsecurity.com/2010/07/experts-warn-of-new-windows-shortcut-flaw/" }, { "tags": [ "x_refsource_CONFIRM", "x_transferred" ], "url": "http://www.sea.siemens.com/us/News/Industrial/Pages/WinCC_Update.aspx" }, { "name": "41753", "tags": [ "vdb-entry", "x_refsource_BID", "x_transferred" ], "url": "http://www.securityfocus.com/bid/41753" }, { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "http://infoworld.com/d/security-central/new-weaponized-virus-targets-industrial-secrets-725" }, { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "http://www.wilderssecurity.com/showpost.php?p=1712134&postcount=22" }, { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "http://www.wired.com/threatlevel/2010/07/siemens-scada/" } ] } ] }, "cveMetadata": { "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "assignerShortName": "mitre", "cveId": "CVE-2010-2772", "datePublished": "2010-07-22T10:00:00.000Z", "dateReserved": "2010-07-21T00:00:00.000Z", "dateUpdated": "2024-08-07T02:46:48.161Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }