{ "containers": { "cna": { "affected": [ { "defaultStatus": "unaffected", "product": "NS15", "vendor": "Omron", "versions": [ { "lessThan": "8.68x", "status": "affected", "version": "8.1xx", "versionType": "custom" } ] }, { "defaultStatus": "unaffected", "product": "NS12", "vendor": "Omron", "versions": [ { "lessThan": "8.68x", "status": "affected", "version": "8.1xx", "versionType": "custom" } ] }, { "defaultStatus": "unaffected", "product": "NS10", "vendor": "Omron", "versions": [ { "lessThan": "8.68x", "status": "affected", "version": "8.1xx", "versionType": "custom" } ] }, { "defaultStatus": "unaffected", "product": "NS8", "vendor": "Omron", "versions": [ { "lessThan": "8.68x", "status": "affected", "version": "8.1xx", "versionType": "custom" } ] }, { "defaultStatus": "unaffected", "product": "NS5", "vendor": "Omron", "versions": [ { "lessThan": "8.68x", "status": "affected", "version": "8.1xx", "versionType": "custom" } ] } ], "credits": [ { "lang": "en", "type": "finder", "value": "Joel Sevilleja Febrer of S2 Grupo" } ], "datePublic": "2014-07-22T06:00:00.000Z", "descriptions": [ { "lang": "en", "supportingMedia": [ { "base64": false, "type": "text/html", "value": "
\nCross-site scripting (XSS) vulnerability in the web application on Omron NS5, NS8, NS10, NS12, and NS15 HMI terminals 8.1xx through 8.68x allows remote authenticated users to inject arbitrary web script or HTML via crafted data.\n\n
" } ], "value": "Cross-site scripting (XSS) vulnerability in the web application on Omron NS5, NS8, NS10, NS12, and NS15 HMI terminals 8.1xx through 8.68x allows remote authenticated users to inject arbitrary web script or HTML via crafted data." } ], "metrics": [ { "cvssV2_0": { "accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "SINGLE", "availabilityImpact": "NONE", "baseScore": 4, "confidentialityImpact": "NONE", "integrityImpact": "PARTIAL", "vectorString": "AV:N/AC:L/Au:S/C:N/I:P/A:N", "version": "2.0" }, "format": "CVSS", "scenarios": [ { "lang": "en", "value": "GENERAL" } ] } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-79", "description": "CWE-79", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6", "shortName": "icscert", "dateUpdated": "2025-10-06T18:01:21.608Z" }, "references": [ { "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-14-203-01" }, { "url": "https://automation.omron.com/en/us/products/" } ], "solutions": [ { "lang": "en", "supportingMedia": [ { "base64": false, "type": "text/html", "value": "Omron Corporation has produced update, Version 8.69x for Japan and \nVersion 8.7x for other countries, that mitigates the identified \nvulnerabilities. The updates for the NS series of HMI terminals can be \ndownloaded at the following locations:
\nNS15 Software Update Version 8.7:
\nNS12 Software Update Version 8.7:
\nNS10 Software Update Version 8.7:
\nNS8 Software Update Version 8.7:
\nNS5 Software Update Version 8.7:
\n\n\n