{ "containers": { "cna": { "affected": [ { "product": "n/a", "vendor": "n/a", "versions": [ { "status": "affected", "version": "n/a" } ] } ], "descriptions": [ { "lang": "en", "value": "The F1BookView ActiveX control in F1 Bookview in Schneider Electric ProClima before 6.2 allows remote attackers to execute arbitrary code or cause a denial of service (memory corruption) via a crafted integer value to the (1) AttachToSS, (2) CopyAll, (3) CopyRange, (4) CopyRangeEx, or (5) SwapTable method, a different vulnerability than CVE-2015-7918." } ], "problemTypes": [ { "descriptions": [ { "description": "n/a", "lang": "en", "type": "text" } ] } ], "providerMetadata": { "dateUpdated": "2015-12-15T02:00:00.000Z", "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "shortName": "mitre" }, "references": [ { "tags": [ "x_refsource_MISC" ], "url": "http://www.zerodayinitiative.com/advisories/ZDI-15-628" }, { "tags": [ "x_refsource_MISC" ], "url": "http://www.zerodayinitiative.com/advisories/ZDI-15-626" }, { "tags": [ "x_refsource_MISC" ], "url": "https://ics-cert.us-cert.gov/advisories/ICSA-15-335-02" }, { "tags": [ "x_refsource_MISC" ], "url": "http://www.zerodayinitiative.com/advisories/ZDI-15-627" }, { "tags": [ "x_refsource_MISC" ], "url": "http://www.zerodayinitiative.com/advisories/ZDI-15-629" }, { "tags": [ "x_refsource_CONFIRM" ], "url": "http://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2015-329-01" } ], "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "cve@mitre.org", "ID": "CVE-2015-8561", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "n/a", "version": { "version_data": [ { "version_value": "n/a" } ] } } ] }, "vendor_name": "n/a" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "The F1BookView ActiveX control in F1 Bookview in Schneider Electric ProClima before 6.2 allows remote attackers to execute arbitrary code or cause a denial of service (memory corruption) via a crafted integer value to the (1) AttachToSS, (2) CopyAll, (3) CopyRange, (4) CopyRangeEx, or (5) SwapTable method, a different vulnerability than CVE-2015-7918." } ] }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "n/a" } ] } ] }, "references": { "reference_data": [ { "name": "http://www.zerodayinitiative.com/advisories/ZDI-15-628", "refsource": "MISC", "url": "http://www.zerodayinitiative.com/advisories/ZDI-15-628" }, { "name": "http://www.zerodayinitiative.com/advisories/ZDI-15-626", "refsource": "MISC", "url": "http://www.zerodayinitiative.com/advisories/ZDI-15-626" }, { "name": "https://ics-cert.us-cert.gov/advisories/ICSA-15-335-02", "refsource": "MISC", "url": "https://ics-cert.us-cert.gov/advisories/ICSA-15-335-02" }, { "name": "http://www.zerodayinitiative.com/advisories/ZDI-15-627", "refsource": "MISC", "url": "http://www.zerodayinitiative.com/advisories/ZDI-15-627" }, { "name": "http://www.zerodayinitiative.com/advisories/ZDI-15-629", "refsource": "MISC", "url": "http://www.zerodayinitiative.com/advisories/ZDI-15-629" }, { "name": "http://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2015-329-01", "refsource": "CONFIRM", "url": "http://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2015-329-01" } ] } } }, "adp": [ { "providerMetadata": { "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE", "dateUpdated": "2024-08-06T08:20:43.541Z" }, "title": "CVE Program Container", "references": [ { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "http://www.zerodayinitiative.com/advisories/ZDI-15-628" }, { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "http://www.zerodayinitiative.com/advisories/ZDI-15-626" }, { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://ics-cert.us-cert.gov/advisories/ICSA-15-335-02" }, { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "http://www.zerodayinitiative.com/advisories/ZDI-15-627" }, { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "http://www.zerodayinitiative.com/advisories/ZDI-15-629" }, { "tags": [ "x_refsource_CONFIRM", "x_transferred" ], "url": "http://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2015-329-01" } ] } ] }, "cveMetadata": { "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "assignerShortName": "mitre", "cveId": "CVE-2015-8561", "datePublished": "2015-12-15T02:00:00.000Z", "dateReserved": "2015-12-14T00:00:00.000Z", "dateUpdated": "2024-09-17T02:33:11.923Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }