{ "containers": { "cna": { "affected": [ { "product": "n/a", "vendor": "n/a", "versions": [ { "status": "affected", "version": "n/a" } ] } ], "descriptions": [ { "lang": "en", "value": "Incorrect access control in RDP Level 1 on STMicroelectronics STM32F0 series devices allows physically present attackers to extract the device's protected firmware via a special sequence of Serial Wire Debug (SWD) commands because there is a race condition between full initialization of the SWD interface and the setup of flash protection." } ], "problemTypes": [ { "descriptions": [ { "description": "n/a", "lang": "en", "type": "text" } ] } ], "providerMetadata": { "dateUpdated": "2018-09-12T15:00:00.000Z", "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "shortName": "mitre" }, "references": [ { "tags": [ "x_refsource_MISC" ], "url": "https://community.st.com/s/question/0D50X00009Xke7aSAB/readout-protection-cracked-on-stm32" }, { "tags": [ "x_refsource_MISC" ], "url": "https://www.usenix.org/conference/woot17/workshop-program/presentation/obermaier" }, { "tags": [ "x_refsource_MISC" ], "url": "https://www.aisec.fraunhofer.de/en/FirmwareProtection.html" } ], "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "cve@mitre.org", "ID": "CVE-2017-18347", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "n/a", "version": { "version_data": [ { "version_value": "n/a" } ] } } ] }, "vendor_name": "n/a" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "Incorrect access control in RDP Level 1 on STMicroelectronics STM32F0 series devices allows physically present attackers to extract the device's protected firmware via a special sequence of Serial Wire Debug (SWD) commands because there is a race condition between full initialization of the SWD interface and the setup of flash protection." } ] }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "n/a" } ] } ] }, "references": { "reference_data": [ { "name": "https://community.st.com/s/question/0D50X00009Xke7aSAB/readout-protection-cracked-on-stm32", "refsource": "MISC", "url": "https://community.st.com/s/question/0D50X00009Xke7aSAB/readout-protection-cracked-on-stm32" }, { "name": "https://www.usenix.org/conference/woot17/workshop-program/presentation/obermaier", "refsource": "MISC", "url": "https://www.usenix.org/conference/woot17/workshop-program/presentation/obermaier" }, { "name": "https://www.aisec.fraunhofer.de/en/FirmwareProtection.html", "refsource": "MISC", "url": "https://www.aisec.fraunhofer.de/en/FirmwareProtection.html" } ] } } }, "adp": [ { "providerMetadata": { "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE", "dateUpdated": "2024-08-05T21:20:51.067Z" }, "title": "CVE Program Container", "references": [ { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://community.st.com/s/question/0D50X00009Xke7aSAB/readout-protection-cracked-on-stm32" }, { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://www.usenix.org/conference/woot17/workshop-program/presentation/obermaier" }, { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://www.aisec.fraunhofer.de/en/FirmwareProtection.html" } ] } ] }, "cveMetadata": { "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "assignerShortName": "mitre", "cveId": "CVE-2017-18347", "datePublished": "2018-09-12T15:00:00.000Z", "dateReserved": "2018-09-12T00:00:00.000Z", "dateUpdated": "2024-09-17T01:36:16.947Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }