{ "containers": { "cna": { "affected": [ { "product": "Evlink Charging Station", "vendor": "Schneider Electric SE", "versions": [ { "status": "affected", "version": "Web Interface, all versions prior to v3.2.0-12_v1" } ] } ], "datePublic": "2018-04-19T00:00:00.000Z", "descriptions": [ { "lang": "en", "value": "In Schneider Electric Evlink Charging Station versions prior to v3.2.0-12_v1, the Web Interface has an issue that may allow a remote attacker to gain administrative privileges without properly authenticating remote users." } ], "problemTypes": [ { "descriptions": [ { "description": "Cookie Modification Privilege Escalation", "lang": "en", "type": "text" } ] } ], "providerMetadata": { "dateUpdated": "2018-07-03T13:57:01.000Z", "orgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb", "shortName": "schneider" }, "references": [ { "tags": [ "x_refsource_CONFIRM" ], "url": "https://www.schneider-electric.com/en/download/document/SEVD-2018-109-01/" } ], "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "cybersecurity@schneider-electric.com", "DATE_PUBLIC": "2018-04-19T00:00:00", "ID": "CVE-2018-7778", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "Evlink Charging Station", "version": { "version_data": [ { "version_value": "Web Interface, all versions prior to v3.2.0-12_v1" } ] } } ] }, "vendor_name": "Schneider Electric SE" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "In Schneider Electric Evlink Charging Station versions prior to v3.2.0-12_v1, the Web Interface has an issue that may allow a remote attacker to gain administrative privileges without properly authenticating remote users." } ] }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "Cookie Modification Privilege Escalation" } ] } ] }, "references": { "reference_data": [ { "name": "https://www.schneider-electric.com/en/download/document/SEVD-2018-109-01/", "refsource": "CONFIRM", "url": "https://www.schneider-electric.com/en/download/document/SEVD-2018-109-01/" } ] } } }, "adp": [ { "providerMetadata": { "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE", "dateUpdated": "2024-08-05T06:37:57.984Z" }, "title": "CVE Program Container", "references": [ { "tags": [ "x_refsource_CONFIRM", "x_transferred" ], "url": "https://www.schneider-electric.com/en/download/document/SEVD-2018-109-01/" } ] } ] }, "cveMetadata": { "assignerOrgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb", "assignerShortName": "schneider", "cveId": "CVE-2018-7778", "datePublished": "2018-07-03T14:00:00.000Z", "dateReserved": "2018-03-08T00:00:00.000Z", "dateUpdated": "2024-09-17T01:07:06.154Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }