{ "containers": { "cna": { "affected": [ { "product": "Schneider Electric Modbus Serial Driver (For 64-bit Windows OS:V3.17 IE 37 and prior , For 32-bit Windows OS:V2.17 IE 27 and prior, and as part of the Driver Suite version:V14.12 and prior)", "vendor": "Schneider", "versions": [ { "status": "affected", "version": "Schneider Electric Modbus Serial Driver (For 64-bit Windows OS:V3.17 IE 37 and prior" }, { "status": "affected", "version": "For 32-bit Windows OS:V2.17 IE 27 and prior" }, { "status": "affected", "version": "and as part of the Driver Suite version:V14.12 and prior)" } ] } ], "datePublic": "2019-04-09T00:00:00.000Z", "descriptions": [ { "lang": "en", "value": "An Externally Controlled Reference to a Resource (CWE-610) vulnerability exists in Schneider Electric Modbus Serial Driver (For 64-bit Windows OS:V3.17 IE 37 and prior , For 32-bit Windows OS:V2.17 IE 27 and prior, and as part of the Driver Suite version:V14.12 and prior) which could allow write access to system files available only to users with SYSTEM privilege or other important user files." } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-610", "description": "Externally Controlled Reference to a Resource (CWE-610)", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2019-05-22T19:27:44.000Z", "orgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb", "shortName": "schneider" }, "references": [ { "tags": [ "x_refsource_CONFIRM" ], "url": "https://www.schneider-electric.com/en/download/document/SEVD-2019-099-01/" } ], "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "cybersecurity@schneider-electric.com", "ID": "CVE-2018-7824", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "Schneider Electric Modbus Serial Driver (For 64-bit Windows OS:V3.17 IE 37 and prior , For 32-bit Windows OS:V2.17 IE 27 and prior, and as part of the Driver Suite version:V14.12 and prior)", "version": { "version_data": [ { "version_value": "Schneider Electric Modbus Serial Driver (For 64-bit Windows OS:V3.17 IE 37 and prior" }, { "version_value": "For 32-bit Windows OS:V2.17 IE 27 and prior" }, { "version_value": "and as part of the Driver Suite version:V14.12 and prior)" } ] } } ] }, "vendor_name": "Schneider" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "An Externally Controlled Reference to a Resource (CWE-610) vulnerability exists in Schneider Electric Modbus Serial Driver (For 64-bit Windows OS:V3.17 IE 37 and prior , For 32-bit Windows OS:V2.17 IE 27 and prior, and as part of the Driver Suite version:V14.12 and prior) which could allow write access to system files available only to users with SYSTEM privilege or other important user files." } ] }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "Externally Controlled Reference to a Resource (CWE-610)" } ] } ] }, "references": { "reference_data": [ { "name": "https://www.schneider-electric.com/en/download/document/SEVD-2019-099-01/", "refsource": "CONFIRM", "url": "https://www.schneider-electric.com/en/download/document/SEVD-2019-099-01/" } ] } } }, "adp": [ { "providerMetadata": { "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE", "dateUpdated": "2024-08-05T06:37:59.163Z" }, "title": "CVE Program Container", "references": [ { "tags": [ "x_refsource_CONFIRM", "x_transferred" ], "url": "https://www.schneider-electric.com/en/download/document/SEVD-2019-099-01/" } ] } ] }, "cveMetadata": { "assignerOrgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb", "assignerShortName": "schneider", "cveId": "CVE-2018-7824", "datePublished": "2019-05-22T19:27:44.000Z", "dateReserved": "2018-03-08T00:00:00.000Z", "dateUpdated": "2024-08-05T06:37:59.163Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }