{ "containers": { "cna": { "affected": [ { "product": "e-litro net", "vendor": "TECSON", "versions": [ { "lessThan": "V6.32", "status": "affected", "version": "unspecified", "versionType": "custom" } ] }, { "product": "LX-Net", "vendor": "TECSON", "versions": [ { "lessThan": "V6.32", "status": "affected", "version": "unspecified", "versionType": "custom" } ] }, { "product": "LX-Q-Net", "vendor": "TECSON", "versions": [ { "lessThan": "V6.32", "status": "affected", "version": "unspecified", "versionType": "custom" } ] }, { "product": "SmartBox 4 LAN", "vendor": "GOK", "versions": [ { "lessThan": "V6.3", "status": "affected", "version": "unspecified", "versionType": "custom" } ] }, { "product": "SmartBox 4 LAN PRO", "vendor": "GOK", "versions": [ { "lessThan": "V6.3", "status": "affected", "version": "unspecified", "versionType": "custom" } ] } ], "credits": [ { "lang": "en", "value": "Maxim Rupp (rupp.it) reported this vulnerability to CERT@VDE." } ], "datePublic": "2019-04-06T00:00:00.000Z", "descriptions": [ { "lang": "en", "value": "In multiple Tecson Tankspion and GOKs SmartBox 4 products the affected application doesn't properly restrict access to an endpoint that is responsible for saving settings, to a unauthenticated user with limited access rights. Based on the lack of adequately implemented access-control rules, by accessing a specific uniform resource locator (URL) on the web server, a malicious user is able to change the application settings without authenticating at all, which violates originally laid ACL rules." } ], "metrics": [ { "cvssV3_1": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 9.8, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" } } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-287", "description": "CWE-287 Improper Authentication", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2022-05-06T17:30:11.000Z", "orgId": "270ccfa6-a436-4e77-922e-914ec3a9685c", "shortName": "CERTVDE" }, "references": [ { "tags": [ "x_refsource_CONFIRM" ], "url": "https://cert.vde.com/en/advisories/VDE-2019-012/" } ], "solutions": [ { "lang": "en", "value": "Upgrade to firmware version > 6.32" } ], "source": { "advisory": "VDE-2019-012", "discovery": "EXTERNAL" }, "title": "TECSON/GOK: Improper Authentication and Access Control on multiple devices", "x_generator": { "engine": "Vulnogram 0.0.9" }, "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "info@cert.vde.com", "DATE_PUBLIC": "2019-04-06T10:00:00.000Z", "ID": "CVE-2019-12254", "STATE": "PUBLIC", "TITLE": "TECSON/GOK: Improper Authentication and Access Control on multiple devices" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "e-litro net", "version": { "version_data": [ { "version_affected": "<", "version_value": "V6.32" } ] } }, { "product_name": "LX-Net", "version": { "version_data": [ { "version_affected": "<", "version_value": "V6.32" } ] } }, { "product_name": "LX-Q-Net", "version": { "version_data": [ { "version_affected": "<", "version_value": "V6.32" } ] } } ] }, "vendor_name": "TECSON" }, { "product": { "product_data": [ { "product_name": "SmartBox 4 LAN", "version": { "version_data": [ { "version_affected": "<", "version_value": "V6.3" } ] } }, { "product_name": "SmartBox 4 LAN PRO", "version": { "version_data": [ { "version_affected": "<", "version_value": "V6.3" } ] } } ] }, "vendor_name": "GOK" } ] } }, "credit": [ { "lang": "eng", "value": "Maxim Rupp (rupp.it) reported this vulnerability to CERT@VDE." } ], "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "In multiple Tecson Tankspion and GOKs SmartBox 4 products the affected application doesn't properly restrict access to an endpoint that is responsible for saving settings, to a unauthenticated user with limited access rights. Based on the lack of adequately implemented access-control rules, by accessing a specific uniform resource locator (URL) on the web server, a malicious user is able to change the application settings without authenticating at all, which violates originally laid ACL rules." } ] }, "generator": { "engine": "Vulnogram 0.0.9" }, "impact": { "cvss": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 9.8, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" } }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "CWE-287 Improper Authentication" } ] } ] }, "references": { "reference_data": [ { "name": "https://cert.vde.com/en/advisories/VDE-2019-012/", "refsource": "CONFIRM", "url": "https://cert.vde.com/en/advisories/VDE-2019-012/" } ] }, "solution": [ { "lang": "en", "value": "Upgrade to firmware version > 6.32" } ], "source": { "advisory": "VDE-2019-012", "discovery": "EXTERNAL" } } }, "adp": [ { "providerMetadata": { "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE", "dateUpdated": "2024-08-04T23:17:39.190Z" }, "title": "CVE Program Container", "references": [ { "tags": [ "x_refsource_CONFIRM", "x_transferred" ], "url": "https://cert.vde.com/en/advisories/VDE-2019-012/" } ] } ] }, "cveMetadata": { "assignerOrgId": "270ccfa6-a436-4e77-922e-914ec3a9685c", "assignerShortName": "CERTVDE", "cveId": "CVE-2019-12254", "datePublished": "2022-05-06T17:30:12.071Z", "dateReserved": "2019-05-21T00:00:00.000Z", "dateUpdated": "2024-09-16T20:22:12.620Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }