{ "containers": { "cna": { "providerMetadata": { "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77", "shortName": "siemens", "dateUpdated": "2025-06-10T15:17:09.328Z" }, "descriptions": [ { "lang": "en", "value": "A vulnerability has been identified in APOGEE MEC/MBC/PXC (P2) (All versions < V2.8.2), APOGEE PXC Compact (BACnet) (All versions < V3.5.3), APOGEE PXC Compact (P2 Ethernet) (All versions >= V2.8.2 < V2.8.19), APOGEE PXC Modular (BACnet) (All versions < V3.5.3), APOGEE PXC Modular (P2 Ethernet) (All versions >= V2.8.2 < V2.8.19), Capital Embedded AR Classic 431-422 (All versions), Capital Embedded AR Classic R20-11 (All versions < V2303), Desigo PXC00-E.D (All versions >= V2.3 < V6.0.327), Desigo PXC00-U (All versions >= V2.3x and < V6.00.327), Desigo PXC001-E.D (All versions >= V2.3 < V6.0.327), Desigo PXC100-E.D (All versions >= V2.3 < V6.0.327), Desigo PXC12-E.D (All versions >= V2.3 < V6.0.327), Desigo PXC128-U (All versions >= V2.3x and < V6.00.327), Desigo PXC200-E.D (All versions >= V2.3 < V6.0.327), Desigo PXC22-E.D (All versions >= V2.3 < V6.0.327), Desigo PXC22.1-E.D (All versions >= V2.3 < V6.0.327), Desigo PXC36.1-E.D (All versions >= V2.3 < V6.0.327), Desigo PXC50-E.D (All versions >= V2.3 < V6.0.327), Desigo PXC64-U (All versions >= V2.3x and < V6.00.327), Desigo PXM20-E (All versions >= V2.3 < V6.0.327), Nucleus NET (All versions), Nucleus ReadyStart V3 (All versions < V2017.02.3), Nucleus Source Code (All versions), SIMOTICS CONNECT 400 (All versions < V0.3.0.330), TALON TC Compact (BACnet) (All versions < V3.5.3), TALON TC Modular (BACnet) (All versions < V3.5.3). By sending specially crafted DHCP packets to a device where the DHCP client is enabled, an attacker could change the IP address of the device to an invalid value." } ], "affected": [ { "vendor": "Siemens", "product": "APOGEE MEC/MBC/PXC (P2)", "versions": [ { "status": "affected", "version": "All versions < V2.8.2" } ], "defaultStatus": "unknown" }, { "vendor": "Siemens", "product": "APOGEE PXC Compact (BACnet)", "versions": [ { "status": "affected", "version": "0", "lessThan": "V3.5.3", "versionType": "custom" } ], "defaultStatus": "unknown" }, { "vendor": "Siemens", "product": "APOGEE PXC Compact (P2 Ethernet)", "versions": [ { "status": "affected", "version": "V2.8.2", "lessThan": "V2.8.19", "versionType": "custom" } ], "defaultStatus": "unknown" }, { "vendor": "Siemens", "product": "APOGEE PXC Modular (BACnet)", "versions": [ { "status": "affected", "version": "0", "lessThan": "V3.5.3", "versionType": "custom" } ], "defaultStatus": "unknown" }, { "vendor": "Siemens", "product": "APOGEE PXC Modular (P2 Ethernet)", "versions": [ { "status": "affected", "version": "V2.8.2", "lessThan": "V2.8.19", "versionType": "custom" } ], "defaultStatus": "unknown" }, { "vendor": "Siemens", "product": "Capital Embedded AR Classic 431-422", "versions": [ { "status": "affected", "version": "0", "lessThan": "*", "versionType": "custom" } ], "defaultStatus": "unknown" }, { "vendor": "Siemens", "product": "Capital Embedded AR Classic R20-11", "versions": [ { "status": "affected", "version": "0", "lessThan": "V2303", "versionType": "custom" } ], "defaultStatus": "unknown" }, { "vendor": "Siemens", "product": "Desigo PXC00-E.D", "versions": [ { "status": "affected", "version": "V2.3", "lessThan": "V6.0.327", "versionType": "custom" } ], "defaultStatus": "unknown" }, { "vendor": "Siemens", "product": "Desigo PXC00-U", "versions": [ { "status": "affected", "version": "All versions >= V2.3x and < V6.00.327" } ], "defaultStatus": "unknown" }, { "vendor": "Siemens", "product": "Desigo PXC001-E.D", "versions": [ { "status": "affected", "version": "V2.3", "lessThan": "V6.0.327", "versionType": "custom" } ], "defaultStatus": "unknown" }, { "vendor": "Siemens", "product": "Desigo PXC100-E.D", "versions": [ { "status": "affected", "version": "V2.3", "lessThan": "V6.0.327", "versionType": "custom" } ], "defaultStatus": "unknown" }, { "vendor": "Siemens", "product": "Desigo PXC12-E.D", "versions": [ { "status": "affected", "version": "V2.3", "lessThan": "V6.0.327", "versionType": "custom" } ], "defaultStatus": "unknown" }, { "vendor": "Siemens", "product": "Desigo PXC128-U", "versions": [ { "status": "affected", "version": "All versions >= V2.3x and < V6.00.327" } ], "defaultStatus": "unknown" }, { "vendor": "Siemens", "product": "Desigo PXC200-E.D", "versions": [ { "status": "affected", "version": "V2.3", "lessThan": "V6.0.327", "versionType": "custom" } ], "defaultStatus": "unknown" }, { "vendor": "Siemens", "product": "Desigo PXC22-E.D", "versions": [ { "status": "affected", "version": "V2.3", "lessThan": "V6.0.327", "versionType": "custom" } ], "defaultStatus": "unknown" }, { "vendor": "Siemens", "product": "Desigo PXC22.1-E.D", "versions": [ { "status": "affected", "version": "V2.3", "lessThan": "V6.0.327", "versionType": "custom" } ], "defaultStatus": "unknown" }, { "vendor": "Siemens", "product": "Desigo PXC36.1-E.D", "versions": [ { "status": "affected", "version": "V2.3", "lessThan": "V6.0.327", "versionType": "custom" } ], "defaultStatus": "unknown" }, { "vendor": "Siemens", "product": "Desigo PXC50-E.D", "versions": [ { "status": "affected", "version": "V2.3", "lessThan": "V6.0.327", "versionType": "custom" } ], "defaultStatus": "unknown" }, { "vendor": "Siemens", "product": "Desigo PXC64-U", "versions": [ { "status": "affected", "version": "All versions >= V2.3x and < V6.00.327" } ], "defaultStatus": "unknown" }, { "vendor": "Siemens", "product": "Desigo PXM20-E", "versions": [ { "status": "affected", "version": "V2.3", "lessThan": "V6.0.327", "versionType": "custom" } ], "defaultStatus": "unknown" }, { "vendor": "Siemens", "product": "Nucleus NET", "versions": [ { "status": "affected", "version": "0", "lessThan": "*", "versionType": "custom" } ], "defaultStatus": "unknown" }, { "vendor": "Siemens", "product": "Nucleus ReadyStart V3", "versions": [ { "status": "affected", "version": "0", "lessThan": "V2017.02.3", "versionType": "custom" } ], "defaultStatus": "unknown" }, { "vendor": "Siemens", "product": "Nucleus Source Code", "versions": [ { "status": "affected", "version": "0", "lessThan": "*", "versionType": "custom" } ], "defaultStatus": "unknown" }, { "vendor": "Siemens", "product": "SIMOTICS CONNECT 400", "versions": [ { "status": "affected", "version": "All versions < V0.3.0.330" } ], "defaultStatus": "unknown" }, { "vendor": "Siemens", "product": "TALON TC Compact (BACnet)", "versions": [ { "status": "affected", "version": "0", "lessThan": "V3.5.3", "versionType": "custom" } ], "defaultStatus": "unknown" }, { "vendor": "Siemens", "product": "TALON TC Modular (BACnet)", "versions": [ { "status": "affected", "version": "0", "lessThan": "V3.5.3", "versionType": "custom" } ], "defaultStatus": "unknown" } ], "metrics": [ { "cvssV3_1": { "version": "3.1", "vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:N/I:L/A:H", "baseScore": 7.1, "baseSeverity": "HIGH" } }, { "cvssV4_0": { "version": "4.0", "vectorString": "CVSS:4.0/AV:A/AC:L/AT:N/PR:N/UI:N/VC:N/VI:L/VA:H/SC:N/SI:N/SA:N", "baseScore": 7.1, "baseSeverity": "HIGH" } } ], "problemTypes": [ { "descriptions": [ { "lang": "en", "cweId": "CWE-20", "description": "CWE-20: Improper Input Validation", "type": "CWE" } ] } ], "references": [ { "tags": [ "x_refsource_MISC" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-434032.pdf" }, { "tags": [ "x_refsource_CONFIRM" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-162506.pdf" }, { "tags": [ "x_refsource_MISC" ], "url": "https://us-cert.cisa.gov/ics/advisories/icsa-20-105-06" }, { "url": "https://cert-portal.siemens.com/productcert/html/ssa-434032.html" }, { "url": "https://cert-portal.siemens.com/productcert/html/ssa-162506.html" } ] }, "adp": [ { "providerMetadata": { "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE", "dateUpdated": "2024-08-05T00:05:43.738Z" }, "title": "CVE Program Container", "references": [ { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-434032.pdf" }, { "tags": [ "x_refsource_CONFIRM", "x_transferred" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-162506.pdf" }, { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://us-cert.cisa.gov/ics/advisories/icsa-20-105-06" }, { "url": "https://cert-portal.siemens.com/productcert/html/ssa-434032.html", "tags": [ "x_transferred" ] }, { "url": "https://cert-portal.siemens.com/productcert/html/ssa-162506.html", "tags": [ "x_transferred" ] } ] } ] }, "cveMetadata": { "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77", "assignerShortName": "siemens", "cveId": "CVE-2019-13939", "datePublished": "2020-01-16T15:35:24.000Z", "dateReserved": "2019-07-18T00:00:00.000Z", "dateUpdated": "2025-06-10T15:17:09.328Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }