{ "containers": { "cna": { "affected": [ { "product": "SIMATIC Drive Controller family", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions < V2.9.2" } ] }, { "product": "SIMATIC ET 200SP Open Controller CPU 1515SP PC (incl. SIPLUS variants)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "product": "SIMATIC ET 200SP Open Controller CPU 1515SP PC2 (incl. SIPLUS variants)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions < V21.9" } ] }, { "product": "SIMATIC S7-1200 CPU family (incl. SIPLUS variants)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions < V4.5.0" } ] }, { "product": "SIMATIC S7-1500 CPU family (incl. related ET200 CPUs and SIPLUS variants)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions < V2.9.2" } ] }, { "product": "SIMATIC S7-1500 Software Controller", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions < V21.9" } ] }, { "product": "SIMATIC S7-PLCSIM Advanced", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions < V4.0" } ] }, { "product": "SINAMICS PERFECT HARMONY GH180 Drives", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "Drives manufactured before 2021-08-13" } ] }, { "product": "SINUMERIK MC", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions < V6.15" } ] }, { "product": "SINUMERIK ONE", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions < V6.15" } ] } ], "descriptions": [ { "lang": "en", "value": "A vulnerability has been identified in SIMATIC Drive Controller family (All versions < V2.9.2), SIMATIC ET 200SP Open Controller CPU 1515SP PC (incl. SIPLUS variants) (All versions), SIMATIC ET 200SP Open Controller CPU 1515SP PC2 (incl. SIPLUS variants) (All versions < V21.9), SIMATIC S7-1200 CPU family (incl. SIPLUS variants) (All versions < V4.5.0), SIMATIC S7-1500 CPU family (incl. related ET200 CPUs and SIPLUS variants) (All versions < V2.9.2), SIMATIC S7-1500 Software Controller (All versions < V21.9), SIMATIC S7-PLCSIM Advanced (All versions < V4.0), SINAMICS PERFECT HARMONY GH180 Drives (Drives manufactured before 2021-08-13), SINUMERIK MC (All versions < V6.15), SINUMERIK ONE (All versions < V6.15). Affected devices are vulnerable to a memory protection bypass through a specific operation. A remote unauthenticated attacker with network access to port 102/tcp could potentially write arbitrary data and code to protected memory areas or read sensitive data to launch further attacks." } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-119", "description": "CWE-119: Improper Restriction of Operations within the Bounds of a Memory Buffer", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2021-09-14T10:47:06.000Z", "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77", "shortName": "siemens" }, "references": [ { "tags": [ "x_refsource_MISC" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-434534.pdf" }, { "tags": [ "x_refsource_MISC" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-434536.pdf" }, { "tags": [ "x_refsource_MISC" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-434535.pdf" } ], "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "productcert@siemens.com", "ID": "CVE-2020-15782", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "SIMATIC Drive Controller family", "version": { "version_data": [ { "version_value": "All versions < V2.9.2" } ] } }, { "product_name": "SIMATIC ET 200SP Open Controller CPU 1515SP PC (incl. SIPLUS variants)", "version": { "version_data": [ { "version_value": "All versions" } ] } }, { "product_name": "SIMATIC ET 200SP Open Controller CPU 1515SP PC2 (incl. SIPLUS variants)", "version": { "version_data": [ { "version_value": "All versions < V21.9" } ] } }, { "product_name": "SIMATIC S7-1200 CPU family (incl. SIPLUS variants)", "version": { "version_data": [ { "version_value": "All versions < V4.5.0" } ] } }, { "product_name": "SIMATIC S7-1500 CPU family (incl. related ET200 CPUs and SIPLUS variants)", "version": { "version_data": [ { "version_value": "All versions < V2.9.2" } ] } }, { "product_name": "SIMATIC S7-1500 Software Controller", "version": { "version_data": [ { "version_value": "All versions < V21.9" } ] } }, { "product_name": "SIMATIC S7-PLCSIM Advanced", "version": { "version_data": [ { "version_value": "All versions < V4.0" } ] } }, { "product_name": "SINAMICS PERFECT HARMONY GH180 Drives", "version": { "version_data": [ { "version_value": "Drives manufactured before 2021-08-13" } ] } }, { "product_name": "SINUMERIK MC", "version": { "version_data": [ { "version_value": "All versions < V6.15" } ] } }, { "product_name": "SINUMERIK ONE", "version": { "version_data": [ { "version_value": "All versions < V6.15" } ] } } ] }, "vendor_name": "Siemens" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "A vulnerability has been identified in SIMATIC Drive Controller family (All versions < V2.9.2), SIMATIC ET 200SP Open Controller CPU 1515SP PC (incl. SIPLUS variants) (All versions), SIMATIC ET 200SP Open Controller CPU 1515SP PC2 (incl. SIPLUS variants) (All versions < V21.9), SIMATIC S7-1200 CPU family (incl. SIPLUS variants) (All versions < V4.5.0), SIMATIC S7-1500 CPU family (incl. related ET200 CPUs and SIPLUS variants) (All versions < V2.9.2), SIMATIC S7-1500 Software Controller (All versions < V21.9), SIMATIC S7-PLCSIM Advanced (All versions < V4.0), SINAMICS PERFECT HARMONY GH180 Drives (Drives manufactured before 2021-08-13), SINUMERIK MC (All versions < V6.15), SINUMERIK ONE (All versions < V6.15). Affected devices are vulnerable to a memory protection bypass through a specific operation. A remote unauthenticated attacker with network access to port 102/tcp could potentially write arbitrary data and code to protected memory areas or read sensitive data to launch further attacks." } ] }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "CWE-119: Improper Restriction of Operations within the Bounds of a Memory Buffer" } ] } ] }, "references": { "reference_data": [ { "name": "https://cert-portal.siemens.com/productcert/pdf/ssa-434534.pdf", "refsource": "MISC", "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-434534.pdf" }, { "name": "https://cert-portal.siemens.com/productcert/pdf/ssa-434536.pdf", "refsource": "MISC", "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-434536.pdf" }, { "name": "https://cert-portal.siemens.com/productcert/pdf/ssa-434535.pdf", "refsource": "MISC", "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-434535.pdf" } ] } } }, "adp": [ { "providerMetadata": { "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE", "dateUpdated": "2024-08-04T13:22:30.758Z" }, "title": "CVE Program Container", "references": [ { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-434534.pdf" }, { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-434536.pdf" }, { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-434535.pdf" } ] }, { "metrics": [ { "cvssV3_1": { "scope": "UNCHANGED", "version": "3.1", "baseScore": 9.8, "attackVector": "NETWORK", "baseSeverity": "CRITICAL", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "integrityImpact": "HIGH", "userInteraction": "NONE", "attackComplexity": "LOW", "availabilityImpact": "HIGH", "privilegesRequired": "NONE", "confidentialityImpact": "HIGH" } }, { "other": { "type": "ssvc", "content": { "timestamp": "2026-06-02T18:50:27.467629Z", "id": "CVE-2020-15782", "options": [ { "Exploitation": "none" }, { "Automatable": "yes" }, { "Technical Impact": "total" } ], "role": "CISA Coordinator", "version": "2.0.3" } } } ], "title": "CISA ADP Vulnrichment", "providerMetadata": { "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "shortName": "CISA-ADP", "dateUpdated": "2026-06-02T18:50:38.536Z" } } ] }, "cveMetadata": { "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77", "assignerShortName": "siemens", "cveId": "CVE-2020-15782", "datePublished": "2021-05-28T16:10:10.000Z", "dateReserved": "2020-07-15T00:00:00.000Z", "dateUpdated": "2026-06-02T18:50:38.536Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.2" }