{ "containers": { "cna": { "affected": [ { "product": "GateManager", "vendor": "Secomea", "versions": [ { "lessThan": "9.4", "status": "affected", "version": "all", "versionType": "custom" } ] } ], "datePublic": "2021-03-04T00:00:00.000Z", "descriptions": [ { "lang": "en", "value": "Improper Input Validation, Cross-site Scripting (XSS) vulnerability in Web GUI of Secomea GateManager allows an attacker to execute arbitrary javascript code. This issue affects: Secomea GateManager all versions prior to 9.4." } ], "metrics": [ { "cvssV3_1": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "LOW", "baseScore": 7.3, "baseSeverity": "HIGH", "confidentialityImpact": "LOW", "integrityImpact": "LOW", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:L/A:L", "version": "3.1" } } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-20", "description": "CWE-20 Improper Input Validation", "lang": "en", "type": "CWE" } ] }, { "descriptions": [ { "cweId": "CWE-79", "description": "CWE-79 Cross-site Scripting (XSS)", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2021-03-05T19:08:21.000Z", "orgId": "f2815942-3388-4c08-ba09-6c15850fda90", "shortName": "Secomea" }, "references": [ { "tags": [ "x_refsource_MISC" ], "url": "https://www.secomea.com/support/cybersecurity-advisory/" } ], "source": { "defect": [ "RD-3452" ], "discovery": "INTERNAL" }, "title": "XSS issue due to insufficient sanitization of input field", "x_generator": { "engine": "Vulnogram 0.0.9" }, "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "VulnerabilityReporting@secomea.com", "DATE_PUBLIC": "2021-03-04T22:00:00.000Z", "ID": "CVE-2020-29029", "STATE": "PUBLIC", "TITLE": "XSS issue due to insufficient sanitization of input field" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "GateManager", "version": { "version_data": [ { "version_affected": "<", "version_name": "all", "version_value": "9.4" } ] } } ] }, "vendor_name": "Secomea" } ] } }, "credit": [ { "lang": "eng" } ], "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "Improper Input Validation, Cross-site Scripting (XSS) vulnerability in Web GUI of Secomea GateManager allows an attacker to execute arbitrary javascript code. This issue affects: Secomea GateManager all versions prior to 9.4." } ] }, "generator": { "engine": "Vulnogram 0.0.9" }, "impact": { "cvss": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "LOW", "baseScore": 7.3, "baseSeverity": "HIGH", "confidentialityImpact": "LOW", "integrityImpact": "LOW", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:L/A:L", "version": "3.1" } }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "CWE-20 Improper Input Validation" } ] }, { "description": [ { "lang": "eng", "value": "CWE-79 Cross-site Scripting (XSS)" } ] } ] }, "references": { "reference_data": [ { "name": "https://www.secomea.com/support/cybersecurity-advisory/", "refsource": "MISC", "url": "https://www.secomea.com/support/cybersecurity-advisory/" } ] }, "source": { "defect": [ "RD-3452" ], "discovery": "INTERNAL" } } }, "adp": [ { "providerMetadata": { "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE", "dateUpdated": "2024-08-04T16:48:01.576Z" }, "title": "CVE Program Container", "references": [ { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://www.secomea.com/support/cybersecurity-advisory/" } ] } ] }, "cveMetadata": { "assignerOrgId": "f2815942-3388-4c08-ba09-6c15850fda90", "assignerShortName": "Secomea", "cveId": "CVE-2020-29029", "datePublished": "2021-03-05T19:08:21.917Z", "dateReserved": "2020-11-24T00:00:00.000Z", "dateUpdated": "2024-09-16T22:31:25.557Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }