{ "containers": { "cna": { "affected": [ { "product": "MELSEC iQ-R, iQ-F, Q, L, and FX series CPU modules", "vendor": "Mitsubishi Electric Corporation", "versions": [ { "status": "affected", "version": "all versions" } ] } ], "descriptions": [ { "lang": "en", "value": "Mitsubishi Electric MELSEC iQ-R, iQ-F, Q, L, and FX series CPU modules all versions contain a vulnerability that allows cleartext transmission of sensitive information between CPU modules and GX Works3 and/or GX Works2 via unspecified vectors." } ], "problemTypes": [ { "descriptions": [ { "description": "Cleartext Transmission of Sensitive Information", "lang": "en", "type": "text" } ] } ], "providerMetadata": { "dateUpdated": "2020-06-23T07:35:23.000Z", "orgId": "ede6fdc4-6654-4307-a26d-3331c018e2ce", "shortName": "jpcert" }, "references": [ { "tags": [ "x_refsource_MISC" ], "url": "https://www.mitsubishielectric.com/en/psirt/vulnerability/pdf/2020-003_en.pdf" }, { "tags": [ "x_refsource_MISC" ], "url": "https://www.mitsubishielectric.co.jp/psirt/vulnerability/pdf/2020-003.pdf" }, { "tags": [ "x_refsource_MISC" ], "url": "https://jvn.jp/en/vu/JVNVU91424496/index.html" } ], "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "vultures@jpcert.or.jp", "ID": "CVE-2020-5594", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "MELSEC iQ-R, iQ-F, Q, L, and FX series CPU modules", "version": { "version_data": [ { "version_value": "all versions" } ] } } ] }, "vendor_name": "Mitsubishi Electric Corporation" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "Mitsubishi Electric MELSEC iQ-R, iQ-F, Q, L, and FX series CPU modules all versions contain a vulnerability that allows cleartext transmission of sensitive information between CPU modules and GX Works3 and/or GX Works2 via unspecified vectors." } ] }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "Cleartext Transmission of Sensitive Information" } ] } ] }, "references": { "reference_data": [ { "name": "https://www.mitsubishielectric.com/en/psirt/vulnerability/pdf/2020-003_en.pdf", "refsource": "MISC", "url": "https://www.mitsubishielectric.com/en/psirt/vulnerability/pdf/2020-003_en.pdf" }, { "name": "https://www.mitsubishielectric.co.jp/psirt/vulnerability/pdf/2020-003.pdf", "refsource": "MISC", "url": "https://www.mitsubishielectric.co.jp/psirt/vulnerability/pdf/2020-003.pdf" }, { "name": "https://jvn.jp/en/vu/JVNVU91424496/index.html", "refsource": "MISC", "url": "https://jvn.jp/en/vu/JVNVU91424496/index.html" } ] } } }, "adp": [ { "providerMetadata": { "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE", "dateUpdated": "2024-08-04T08:30:24.558Z" }, "title": "CVE Program Container", "references": [ { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://www.mitsubishielectric.com/en/psirt/vulnerability/pdf/2020-003_en.pdf" }, { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://www.mitsubishielectric.co.jp/psirt/vulnerability/pdf/2020-003.pdf" }, { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://jvn.jp/en/vu/JVNVU91424496/index.html" } ] } ] }, "cveMetadata": { "assignerOrgId": "ede6fdc4-6654-4307-a26d-3331c018e2ce", "assignerShortName": "jpcert", "cveId": "CVE-2020-5594", "datePublished": "2020-06-23T07:35:23.000Z", "dateReserved": "2020-01-06T00:00:00.000Z", "dateUpdated": "2024-08-04T08:30:24.558Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }