{ "containers": { "cna": { "affected": [ { "product": "UC20-WL2000-AC (No. 1334950000)", "vendor": "Weidmüller", "versions": [ { "lessThanOrEqual": "1.9.0", "status": "affected", "version": "1.3.0", "versionType": "custom" }, { "lessThanOrEqual": "1.10.2", "status": "affected", "version": "1.10.0", "versionType": "custom" }, { "lessThanOrEqual": "1.12.1", "status": "affected", "version": "1.11.0", "versionType": "custom" } ] }, { "product": "UC20-WL2000-IOT (No. 1334990000)", "vendor": "Weidmüller", "versions": [ { "lessThanOrEqual": "1.9.0", "status": "affected", "version": "1.3.0", "versionType": "custom" }, { "lessThanOrEqual": "1.10.2", "status": "affected", "version": "1.10.0", "versionType": "custom" }, { "lessThanOrEqual": "1.12.1", "status": "affected", "version": "1.11.0", "versionType": "custom" } ] }, { "product": "IOT-GW30 (No. 2682620000)", "vendor": "Weidmüller", "versions": [ { "lessThanOrEqual": "1.9.0", "status": "affected", "version": "1.3.0", "versionType": "custom" }, { "lessThanOrEqual": "1.10.2", "status": "affected", "version": "1.10.0", "versionType": "custom" }, { "lessThanOrEqual": "1.12.1", "status": "affected", "version": "1.11.0", "versionType": "custom" } ] }, { "product": "IOT-GW30-4G-EU (No. 2682630000)", "vendor": "Weidmüller", "versions": [ { "lessThanOrEqual": "1.9.0", "status": "affected", "version": "1.3.0", "versionType": "custom" }, { "lessThanOrEqual": "1.10.2", "status": "affected", "version": "1.10.0", "versionType": "custom" }, { "lessThanOrEqual": "1.12.1", "status": "affected", "version": "1.11.0", "versionType": "custom" } ] } ], "credits": [ { "lang": "en", "value": "Reported by Weidmüller." } ], "datePublic": "2021-05-04T00:00:00.000Z", "descriptions": [ { "lang": "en", "value": "In Weidmüller u-controls and IoT-Gateways in versions up to 1.12.1 a network port intended only for device-internal usage is accidentally accessible via external network interfaces. By exploiting this vulnerability the device may be manipulated or the operation may be stopped." } ], "metrics": [ { "cvssV3_1": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 9.4, "baseSeverity": "CRITICAL", "confidentialityImpact": "LOW", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:H/A:H", "version": "3.1" } } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-668", "description": "CWE-668 Exposure of Resource to Wrong Sphere", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2021-05-13T13:45:25.000Z", "orgId": "270ccfa6-a436-4e77-922e-914ec3a9685c", "shortName": "CERTVDE" }, "references": [ { "tags": [ "x_refsource_CONFIRM" ], "url": "https://cert.vde.com/en-us/advisories/vde-2021-016" } ], "solutions": [ { "lang": "en", "value": "Weidmüller recommends upgrading affected devices to the current firmware version 1.12.3 or higher which fixes this vulnerability." } ], "source": { "advisory": "VDE-2021-016", "defect": [ "VDE-2021-016" ], "discovery": "INTERNAL" }, "title": "WEIDMUELLER: Accidentally open network port in u-controls and IoT-Gateways", "workarounds": [ { "lang": "en", "value": "Restrict access to the network the device is connected to.\nDo not directly connect the device to the internet." } ], "x_generator": { "engine": "Vulnogram 0.0.9" }, "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "info@cert.vde.com", "DATE_PUBLIC": "2021-05-04T10:00:00.000Z", "ID": "CVE-2021-20999", "STATE": "PUBLIC", "TITLE": "WEIDMUELLER: Accidentally open network port in u-controls and IoT-Gateways" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "UC20-WL2000-AC (No. 1334950000)", "version": { "version_data": [ { "version_affected": "<=", "version_name": "1.3.0", "version_value": "1.9.0" }, { "version_affected": "<=", "version_name": "1.10.0", "version_value": "1.10.2" }, { "version_affected": "<=", "version_name": "1.11.0", "version_value": "1.12.1" } ] } }, { "product_name": "UC20-WL2000-IOT (No. 1334990000)", "version": { "version_data": [ { "version_affected": "<=", "version_name": "1.3.0", "version_value": "1.9.0" }, { "version_affected": "<=", "version_name": "1.10.0", "version_value": "1.10.2" }, { "version_affected": "<=", "version_name": "1.11.0", "version_value": "1.12.1" } ] } }, { "product_name": "IOT-GW30 (No. 2682620000)", "version": { "version_data": [ { "version_affected": "<=", "version_name": "1.3.0", "version_value": "1.9.0" }, { "version_affected": "<=", "version_name": "1.10.0", "version_value": "1.10.2" }, { "version_affected": "<=", "version_name": "1.11.0", "version_value": "1.12.1" } ] } }, { "product_name": "IOT-GW30-4G-EU (No. 2682630000)", "version": { "version_data": [ { "version_affected": "<=", "version_name": "1.3.0", "version_value": "1.9.0" }, { "version_affected": "<=", "version_name": "1.10.0", "version_value": "1.10.2" }, { "version_affected": "<=", "version_name": "1.11.0", "version_value": "1.12.1" } ] } } ] }, "vendor_name": "Weidmüller" } ] } }, "credit": [ { "lang": "eng", "value": "Reported by Weidmüller." } ], "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "In Weidmüller u-controls and IoT-Gateways in versions up to 1.12.1 a network port intended only for device-internal usage is accidentally accessible via external network interfaces. By exploiting this vulnerability the device may be manipulated or the operation may be stopped." } ] }, "generator": { "engine": "Vulnogram 0.0.9" }, "impact": { "cvss": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 9.4, "baseSeverity": "CRITICAL", "confidentialityImpact": "LOW", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:H/A:H", "version": "3.1" } }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "CWE-668 Exposure of Resource to Wrong Sphere" } ] } ] }, "references": { "reference_data": [ { "name": "https://cert.vde.com/en-us/advisories/vde-2021-016", "refsource": "CONFIRM", "url": "https://cert.vde.com/en-us/advisories/vde-2021-016" } ] }, "solution": [ { "lang": "en", "value": "Weidmüller recommends upgrading affected devices to the current firmware version 1.12.3 or higher which fixes this vulnerability." } ], "source": { "advisory": "VDE-2021-016", "defect": [ "VDE-2021-016" ], "discovery": "INTERNAL" }, "work_around": [ { "lang": "en", "value": "Restrict access to the network the device is connected to.\nDo not directly connect the device to the internet." } ] } }, "adp": [ { "providerMetadata": { "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE", "dateUpdated": "2024-08-03T17:53:23.078Z" }, "title": "CVE Program Container", "references": [ { "tags": [ "x_refsource_CONFIRM", "x_transferred" ], "url": "https://cert.vde.com/en-us/advisories/vde-2021-016" } ] } ] }, "cveMetadata": { "assignerOrgId": "270ccfa6-a436-4e77-922e-914ec3a9685c", "assignerShortName": "CERTVDE", "cveId": "CVE-2021-20999", "datePublished": "2021-05-13T13:45:25.284Z", "dateReserved": "2020-12-17T00:00:00.000Z", "dateUpdated": "2024-09-17T01:16:17.295Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }