{ "containers": { "cna": { "affected": [ { "product": "Siemens Solid Edge", "vendor": "n/a", "versions": [ { "status": "affected", "version": "Solid Edge SE2020 – All versions before 2020MP14" }, { "status": "affected", "version": "Solid Edge SE2021 – All versions before SE2021MP5" } ] } ], "descriptions": [ { "lang": "en", "value": "The ugeom2d.dll library in all versions of Solid Edge SE2020 before 2020MP14 and all versions of Solid Edge SE2021 before SE2021MP5 lack proper validation of user-supplied data when parsing DFT files. This could result in an out-of-bounds write past the end of an allocated structure. An attacker could leverage this vulnerability to execute code in the context of the current process." } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-787", "description": "OUT-OF-BOUNDS WRITE CWE-787", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2021-08-24T13:06:13.000Z", "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77", "shortName": "siemens" }, "references": [ { "tags": [ "x_refsource_MISC" ], "url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-159-09" }, { "tags": [ "x_refsource_MISC" ], "url": "https://www.zerodayinitiative.com/advisories/ZDI-21-998/" } ], "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "productcert@siemens.com", "ID": "CVE-2021-31342", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "Siemens Solid Edge", "version": { "version_data": [ { "version_value": "Solid Edge SE2020 – All versions before 2020MP14" }, { "version_value": "Solid Edge SE2021 – All versions before SE2021MP5" } ] } } ] }, "vendor_name": "n/a" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "The ugeom2d.dll library in all versions of Solid Edge SE2020 before 2020MP14 and all versions of Solid Edge SE2021 before SE2021MP5 lack proper validation of user-supplied data when parsing DFT files. This could result in an out-of-bounds write past the end of an allocated structure. An attacker could leverage this vulnerability to execute code in the context of the current process." } ] }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "OUT-OF-BOUNDS WRITE CWE-787" } ] } ] }, "references": { "reference_data": [ { "name": "https://us-cert.cisa.gov/ics/advisories/icsa-21-159-09", "refsource": "MISC", "url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-159-09" }, { "name": "https://www.zerodayinitiative.com/advisories/ZDI-21-998/", "refsource": "MISC", "url": "https://www.zerodayinitiative.com/advisories/ZDI-21-998/" } ] } } }, "adp": [ { "providerMetadata": { "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE", "dateUpdated": "2024-08-03T22:55:53.569Z" }, "title": "CVE Program Container", "references": [ { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-159-09" }, { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://www.zerodayinitiative.com/advisories/ZDI-21-998/" } ] } ] }, "cveMetadata": { "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77", "assignerShortName": "siemens", "cveId": "CVE-2021-31342", "datePublished": "2021-06-08T19:47:16.000Z", "dateReserved": "2021-04-15T00:00:00.000Z", "dateUpdated": "2024-08-03T22:55:53.569Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }