{ "containers": { "cna": { "affected": [ { "product": "RMC-100 (Standard)", "vendor": "ABB", "versions": [ { "lessThan": "2105457-037", "status": "affected", "version": "unspecified", "versionType": "custom" } ] }, { "product": "RMC-100-LITE", "vendor": "ABB", "versions": [ { "lessThan": "2106229-011", "status": "affected", "version": "unspecified", "versionType": "custom" } ] }, { "product": "XIO", "vendor": "ABB", "versions": [ { "lessThan": "2106198-008", "status": "affected", "version": "unspecified", "versionType": "custom" } ] }, { "product": "XFCG5", "vendor": "ABB", "versions": [ { "lessThan": "2105805-016", "status": "affected", "version": "unspecified", "versionType": "custom" } ] }, { "product": "XRCG5", "vendor": "ABB", "versions": [ { "lessThan": "2105864-016", "status": "affected", "version": "unspecified", "versionType": "custom" } ] }, { "product": "uFLOG5", "vendor": "ABB", "versions": [ { "lessThan": "2105298-024", "status": "affected", "version": "unspecified", "versionType": "custom" } ] }, { "product": "UDC", "vendor": "ABB", "versions": [ { "lessThan": "2106177-007", "status": "affected", "version": "unspecified", "versionType": "custom" } ] } ], "credits": [ { "lang": "en", "value": "ABB thanks Vera Mens at Claroty Research for helping to identify the vulnerabilities and protecting our customers." } ], "datePublic": "2022-07-14T00:00:00.000Z", "descriptions": [ { "lang": "en", "value": "Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal'), Improper Neutralization of Special Elements used in a Command ('Command Injection') vulnerability in flow computer and remote controller products of ABB ( RMC-100 (Standard), RMC-100-LITE, XIO, XFCG5 , XRCG5 , uFLOG5 , UDC) allows an attacker who successfully exploited this vulnerability could insert and run arbitrary code in an affected system node." } ], "metrics": [ { "cvssV3_1": { "attackComplexity": "HIGH", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 8.1, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" } } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-22", "description": "CWE-22 Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal')", "lang": "en", "type": "CWE" } ] }, { "descriptions": [ { "cweId": "CWE-77", "description": "CWE-77 Improper Neutralization of Special Elements used in a Command ('Command Injection')", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2022-07-21T15:34:49.000Z", "orgId": "2b718523-d88f-4f37-9bbd-300c20644bf9", "shortName": "ABB" }, "references": [ { "tags": [ "x_refsource_MISC" ], "url": "https://search.abb.com/library/Download.aspx?DocumentID=9AKK108467A0927&LanguageCode=en&DocumentPartId=&Action=Launch&_ga" } ], "source": { "discovery": "UNKNOWN" }, "title": "ABB Flow Computer and Remote Controllers Path Traversal Vulnerability in Totalflow TCP protocol can lead to root access", "x_generator": { "engine": "Vulnogram 0.0.9" }, "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "cybersecurity@ch.abb.com", "DATE_PUBLIC": "2022-07-14T06:51:00.000Z", "ID": "CVE-2022-0902", "STATE": "PUBLIC", "TITLE": "ABB Flow Computer and Remote Controllers Path Traversal Vulnerability in Totalflow TCP protocol can lead to root access" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "RMC-100 (Standard)", "version": { "version_data": [ { "version_affected": "<", "version_value": "2105457-037" } ] } }, { "product_name": "RMC-100-LITE", "version": { "version_data": [ { "version_affected": "<", "version_value": "2106229-011" } ] } }, { "product_name": "XIO", "version": { "version_data": [ { "version_affected": "<", "version_value": "2106198-008" } ] } }, { "product_name": "XFCG5", "version": { "version_data": [ { "version_affected": "<", "version_value": "2105805-016" } ] } }, { "product_name": "XRCG5", "version": { "version_data": [ { "version_affected": "<", "version_value": "2105864-016" } ] } }, { "product_name": "uFLOG5", "version": { "version_data": [ { "version_affected": "<", "version_value": "2105298-024" } ] } }, { "product_name": "UDC", "version": { "version_data": [ { "version_affected": "<", "version_value": "2106177-007" } ] } } ] }, "vendor_name": "ABB" } ] } }, "credit": [ { "lang": "eng", "value": "ABB thanks Vera Mens at Claroty Research for helping to identify the vulnerabilities and protecting our customers." } ], "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal'), Improper Neutralization of Special Elements used in a Command ('Command Injection') vulnerability in flow computer and remote controller products of ABB ( RMC-100 (Standard), RMC-100-LITE, XIO, XFCG5 , XRCG5 , uFLOG5 , UDC) allows an attacker who successfully exploited this vulnerability could insert and run arbitrary code in an affected system node." } ] }, "generator": { "engine": "Vulnogram 0.0.9" }, "impact": { "cvss": { "attackComplexity": "HIGH", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 8.1, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" } }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "CWE-22 Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal')" } ] }, { "description": [ { "lang": "eng", "value": "CWE-77 Improper Neutralization of Special Elements used in a Command ('Command Injection')" } ] } ] }, "references": { "reference_data": [ { "name": "https://search.abb.com/library/Download.aspx?DocumentID=9AKK108467A0927&LanguageCode=en&DocumentPartId=&Action=Launch&_ga", "refsource": "MISC", "url": "https://search.abb.com/library/Download.aspx?DocumentID=9AKK108467A0927&LanguageCode=en&DocumentPartId=&Action=Launch&_ga" } ] }, "source": { "discovery": "UNKNOWN" } } }, "adp": [ { "providerMetadata": { "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE", "dateUpdated": "2024-08-02T23:47:42.131Z" }, "title": "CVE Program Container", "references": [ { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://search.abb.com/library/Download.aspx?DocumentID=9AKK108467A0927&LanguageCode=en&DocumentPartId=&Action=Launch&_ga" } ] } ] }, "cveMetadata": { "assignerOrgId": "2b718523-d88f-4f37-9bbd-300c20644bf9", "assignerShortName": "ABB", "cveId": "CVE-2022-0902", "datePublished": "2022-07-21T15:34:49.705Z", "dateReserved": "2022-03-09T00:00:00.000Z", "dateUpdated": "2024-09-17T02:00:38.883Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }