{ "dataType": "CVE_RECORD", "dataVersion": "5.1", "cveMetadata": { "state": "PUBLISHED", "cveId": "CVE-2022-22731", "assignerOrgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb", "assignerShortName": "schneider", "dateUpdated": "2025-02-05T20:09:04.898Z", "dateReserved": "2022-01-06T00:00:00.000Z", "datePublished": "2023-01-30T00:00:00.000Z" }, "containers": { "cna": { "datePublic": "2022-06-14T00:00:00.000Z", "providerMetadata": { "orgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb", "shortName": "schneider", "dateUpdated": "2023-01-30T00:00:00.000Z" }, "descriptions": [ { "lang": "en", "value": "A CWE-22: Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal') vulnerability exists in a function that could allow an attacker to create or overwrite critical files that are used to execute code, such as programs or libraries and cause path traversal attacks. Affected Products: EcoStruxure Power Commission (Versions prior to V2.22)" } ], "affected": [ { "vendor": "Schneider Electric", "product": "EcoStruxure Power Commission", "versions": [ { "version": "All", "status": "affected", "lessThan": "V2.22", "versionType": "custom" } ] } ], "references": [ { "url": "https://download.schneider-electric.com/files?p_enDocType=Security+and+Safety+Notice&p_File_Name=SEVD-2022-165-05_EcoStruxure_Power_Commission_Security_Notification.pdf" } ], "metrics": [ { "cvssV3_1": { "version": "3.1", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:U/C:H/I:N/A:N", "attackVector": "NETWORK", "attackComplexity": "LOW", "privilegesRequired": "NONE", "userInteraction": "REQUIRED", "scope": "UNCHANGED", "confidentialityImpact": "HIGH", "integrityImpact": "NONE", "availabilityImpact": "NONE", "baseScore": 6.5, "baseSeverity": "MEDIUM" } } ], "problemTypes": [ { "descriptions": [ { "type": "CWE", "lang": "en", "description": "CWE-22 Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal')", "cweId": "CWE-22" } ] } ], "x_generator": { "engine": "Vulnogram 0.0.9" }, "source": { "discovery": "UNKNOWN" } }, "adp": [ { "providerMetadata": { "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE", "dateUpdated": "2024-08-03T03:21:48.950Z" }, "title": "CVE Program Container", "references": [ { "url": "https://download.schneider-electric.com/files?p_enDocType=Security+and+Safety+Notice&p_File_Name=SEVD-2022-165-05_EcoStruxure_Power_Commission_Security_Notification.pdf", "tags": [ "x_transferred" ] } ] }, { "metrics": [ { "other": { "type": "ssvc", "content": { "timestamp": "2025-02-05T19:50:48.313706Z", "id": "CVE-2022-22731", "options": [ { "Exploitation": "none" }, { "Automatable": "no" }, { "Technical Impact": "partial" } ], "role": "CISA Coordinator", "version": "2.0.3" } } } ], "title": "CISA ADP Vulnrichment", "providerMetadata": { "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "shortName": "CISA-ADP", "dateUpdated": "2025-02-05T20:09:04.898Z" } } ] } }