{ "dataType": "CVE_RECORD", "dataVersion": "5.1", "cveMetadata": { "cveId": "CVE-2022-2660", "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6", "state": "PUBLISHED", "assignerShortName": "icscert", "requesterUserId": "548e5310-2409-4eaf-9220-2910d23bb95a", "dateReserved": "2022-08-04T14:26:47.606Z", "datePublished": "2022-12-13T21:26:57.865Z", "dateUpdated": "2025-04-16T16:04:37.830Z" }, "containers": { "cna": { "affected": [ { "defaultStatus": "unaffected", "product": "Industrial Automation DIALink", "vendor": "Delta Electronics", "versions": [ { "lessThanOrEqual": " 1.4.0.0", "status": "affected", "version": "0", "versionType": "custom" } ] } ], "credits": [ { "lang": "en", "type": "finder", "user": "00000000-0000-4000-9000-000000000000", "value": "Y4er working with Trend Micro Zero Day Initiative reported this vulnerability to CISA" } ], "descriptions": [ { "lang": "en", "supportingMedia": [ { "base64": false, "type": "text/html", "value": "

Delta Industrial Automation DIALink versions 1.4.0.0 and prior are vulnerable to the use of a hard-coded cryptographic key which could allow an attacker to decrypt sensitive data and compromise the machine.

\n\n

" } ], "value": "Delta Industrial Automation DIALink versions 1.4.0.0 and prior are vulnerable to the use of a hard-coded cryptographic key which could allow an attacker to decrypt sensitive data and compromise the machine.\n\n\n\n\n\n" } ], "metrics": [ { "cvssV3_1": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 9.8, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, "format": "CVSS", "scenarios": [ { "lang": "en", "value": "GENERAL" } ] } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-321", "description": "CWE-321 Use of Hard-Coded Cryptographic Key", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6", "shortName": "icscert", "dateUpdated": "2022-12-13T21:26:57.865Z" }, "references": [ { "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-235-02" } ], "solutions": [ { "lang": "en", "supportingMedia": [ { "base64": false, "type": "text/html", "value": "\n\nMitigation measures have been added in DIALink v1.5.0.0. \n\nDelta Electronics recommends users contact Delta Electronics customer service or a Delta Electronics representative for this release, as it will not be released publicly.\n\n
" } ], "value": "\nMitigation measures have been added in DIALink v1.5.0.0. \n\nDelta Electronics recommends users contact Delta Electronics customer service https://www.deltaww.com/en/customerService  or a Delta Electronics representative for this release, as it will not be released publicly.\n\n\n" } ], "source": { "discovery": "EXTERNAL" }, "x_generator": { "engine": "Vulnogram 0.1.0-dev" } }, "adp": [ { "providerMetadata": { "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE", "dateUpdated": "2024-08-03T00:46:03.794Z" }, "title": "CVE Program Container", "references": [ { "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-235-02", "tags": [ "x_transferred" ] } ] }, { "metrics": [ { "other": { "type": "ssvc", "content": { "timestamp": "2025-04-16T15:52:26.337503Z", "id": "CVE-2022-2660", "options": [ { "Exploitation": "none" }, { "Automatable": "yes" }, { "Technical Impact": "total" } ], "role": "CISA Coordinator", "version": "2.0.3" } } } ], "title": "CISA ADP Vulnrichment", "providerMetadata": { "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "shortName": "CISA-ADP", "dateUpdated": "2025-04-16T16:04:37.830Z" } } ] } }