{ "dataType": "CVE_RECORD", "dataVersion": "5.1", "cveMetadata": { "cveId": "CVE-2022-32257", "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77", "state": "PUBLISHED", "assignerShortName": "siemens", "dateReserved": "2022-06-02T21:55:14.863Z", "datePublished": "2024-03-12T10:41:49.947Z", "dateUpdated": "2024-08-03T07:39:50.311Z" }, "containers": { "cna": { "providerMetadata": { "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77", "shortName": "siemens", "dateUpdated": "2024-03-12T10:41:49.947Z" }, "descriptions": [ { "lang": "en", "value": "A vulnerability has been identified in SINEMA Remote Connect Server (All versions < V3.2). The affected application consists of a web service that lacks proper access control for some of the endpoints. This could lead to unauthorized access to resources and potentially lead to code execution." } ], "affected": [ { "vendor": "Siemens", "product": "SINEMA Remote Connect Server", "versions": [ { "status": "affected", "version": "0", "lessThan": "V3.2", "versionType": "custom" } ], "defaultStatus": "unknown" } ], "metrics": [ { "cvssV3_1": { "version": "3.1", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C", "baseScore": 9.8, "baseSeverity": "CRITICAL" } } ], "problemTypes": [ { "descriptions": [ { "lang": "en", "cweId": "CWE-284", "description": "CWE-284: Improper Access Control", "type": "CWE" } ] } ], "references": [ { "url": "https://cert-portal.siemens.com/productcert/html/ssa-576771.html" } ] }, "adp": [ { "affected": [ { "vendor": "siemens", "product": "sinema_remote_connect_server", "cpes": [ "cpe:2.3:a:siemens:sinema_remote_connect_server:*:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "versions": [ { "version": "0", "status": "affected", "lessThan": "3.2", "versionType": "custom" } ] } ], "metrics": [ { "other": { "type": "ssvc", "content": { "timestamp": "2024-03-12T13:05:21.083973Z", "id": "CVE-2022-32257", "options": [ { "Exploitation": "none" }, { "Automatable": "yes" }, { "Technical Impact": "total" } ], "role": "CISA Coordinator", "version": "2.0.3" } } } ], "title": "CISA ADP Vulnrichment", "providerMetadata": { "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "shortName": "CISA-ADP", "dateUpdated": "2024-07-26T18:02:12.980Z" } }, { "providerMetadata": { "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE", "dateUpdated": "2024-08-03T07:39:50.311Z" }, "title": "CVE Program Container", "references": [ { "url": "https://cert-portal.siemens.com/productcert/html/ssa-576771.html", "tags": [ "x_transferred" ] } ] } ] } }