{ "dataType": "CVE_RECORD", "dataVersion": "5.1", "cveMetadata": { "state": "PUBLISHED", "cveId": "CVE-2022-33194", "assignerOrgId": "b86d76f8-0f8a-4a96-a78d-d8abfc7fc29b", "assignerShortName": "talos", "datePublished": "2022-10-25T16:33:51.055Z", "dateUpdated": "2025-04-15T18:46:25.186Z", "dateReserved": "2022-06-13T00:00:00.000Z" }, "containers": { "cna": { "datePublic": "2022-10-20T00:00:00.000Z", "providerMetadata": { "orgId": "b86d76f8-0f8a-4a96-a78d-d8abfc7fc29b", "shortName": "talos", "dateUpdated": "2022-10-25T00:00:00.000Z" }, "descriptions": [ { "lang": "en", "value": "Four OS command injection vulnerabilities exist in the XCMD testWifiAP functionality of Abode Systems, Inc. iota All-In-One Security Kit 6.9X and 6.9Z. A XCMD can lead to arbitrary command execution. An attacker can send a sequence of malicious commands to trigger these vulnerabilities.This vulnerability focuses on the unsafe use of the `WL_Key` and `WL_DefaultKeyID` configuration values in the function located at offset `0x1c7d28` of firmware 6.9Z , and even more specifically on the command execution occuring at offset `0x1c7f6c`." } ], "affected": [ { "vendor": "abode systems, inc.", "product": "iota All-In-One Security Kit", "versions": [ { "version": "6.9X", "status": "affected" }, { "version": "6.9Z", "status": "affected" } ] } ], "references": [ { "url": "https://talosintelligence.com/vulnerability_reports/TALOS-2022-1559" } ], "metrics": [ { "cvssV3_0": { "version": "3.0", "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H", "attackVector": "NETWORK", "attackComplexity": "LOW", "privilegesRequired": "NONE", "userInteraction": "NONE", "scope": "CHANGED", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "availabilityImpact": "HIGH", "baseScore": 10, "baseSeverity": "CRITICAL" } } ], "problemTypes": [ { "descriptions": [ { "type": "CWE", "lang": "en", "description": "CWE-78: Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')", "cweId": "CWE-78" } ] } ] }, "adp": [ { "providerMetadata": { "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE", "dateUpdated": "2024-08-03T08:01:20.285Z" }, "title": "CVE Program Container", "references": [ { "url": "https://talosintelligence.com/vulnerability_reports/TALOS-2022-1559", "tags": [ "x_transferred" ] } ] }, { "metrics": [ { "other": { "type": "ssvc", "content": { "timestamp": "2025-04-15T18:19:30.363410Z", "id": "CVE-2022-33194", "options": [ { "Exploitation": "poc" }, { "Automatable": "yes" }, { "Technical Impact": "total" } ], "role": "CISA Coordinator", "version": "2.0.3" } } } ], "title": "CISA ADP Vulnrichment", "providerMetadata": { "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "shortName": "CISA-ADP", "dateUpdated": "2025-04-15T18:46:25.186Z" } } ] } }