{ "dataType": "CVE_RECORD", "dataVersion": "5.1", "cveMetadata": { "cveId": "CVE-2022-46823", "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77", "state": "PUBLISHED", "assignerShortName": "siemens", "dateReserved": "2022-12-08T15:19:35.234Z", "datePublished": "2023-01-10T11:39:46.211Z", "dateUpdated": "2025-04-09T14:01:27.985Z" }, "containers": { "cna": { "providerMetadata": { "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77", "shortName": "siemens", "dateUpdated": "2023-01-10T11:39:46.211Z" }, "descriptions": [ { "lang": "en", "value": "A vulnerability has been identified in Mendix SAML (Mendix 8 compatible) (All versions >= V2.3.0 < V2.3.4), Mendix SAML (Mendix 9 compatible, New Track) (All versions >= V3.3.0 < V3.3.9), Mendix SAML (Mendix 9 compatible, Upgrade Track) (All versions >= V3.3.0 < V3.3.8). The affected module is vulnerable to reflected cross-site scripting (XSS) attacks. This could allow an attacker to extract sensitive information by tricking users into accessing a malicious link." } ], "affected": [ { "vendor": "Siemens", "product": "Mendix SAML (Mendix 8 compatible)", "versions": [ { "version": "All versions >= V2.3.0 < V2.3.4", "status": "affected" } ], "defaultStatus": "unknown" }, { "vendor": "Siemens", "product": "Mendix SAML (Mendix 9 compatible, New Track)", "versions": [ { "version": "All versions >= V3.3.0 < V3.3.9", "status": "affected" } ], "defaultStatus": "unknown" }, { "vendor": "Siemens", "product": "Mendix SAML (Mendix 9 compatible, Upgrade Track)", "versions": [ { "version": "All versions >= V3.3.0 < V3.3.8", "status": "affected" } ], "defaultStatus": "unknown" } ], "metrics": [ { "cvssV3_1": { "version": "3.1", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:C/C:H/I:H/A:N/E:P/RL:O/RC:C", "baseScore": 9.3, "baseSeverity": "CRITICAL" } } ], "problemTypes": [ { "descriptions": [ { "lang": "en", "cweId": "CWE-79", "description": "CWE-79: Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting')", "type": "CWE" } ] } ], "references": [ { "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-496604.pdf" } ] }, "adp": [ { "providerMetadata": { "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE", "dateUpdated": "2024-08-03T14:39:38.695Z" }, "title": "CVE Program Container", "references": [ { "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-496604.pdf", "tags": [ "x_transferred" ] } ] }, { "metrics": [ { "other": { "type": "ssvc", "content": { "timestamp": "2025-04-09T14:01:19.219213Z", "id": "CVE-2022-46823", "options": [ { "Exploitation": "none" }, { "Automatable": "no" }, { "Technical Impact": "total" } ], "role": "CISA Coordinator", "version": "2.0.3" } } } ], "title": "CISA ADP Vulnrichment", "providerMetadata": { "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "shortName": "CISA-ADP", "dateUpdated": "2025-04-09T14:01:27.985Z" } } ] } }