{ "dataType": "CVE_RECORD", "dataVersion": "5.2", "cveMetadata": { "cveId": "CVE-2022-47374", "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77", "state": "PUBLISHED", "assignerShortName": "siemens", "dateReserved": "2022-12-13T14:51:37.209Z", "datePublished": "2023-12-12T11:25:31.314Z", "dateUpdated": "2026-02-25T16:34:35.793Z" }, "containers": { "cna": { "providerMetadata": { "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77", "shortName": "siemens", "dateUpdated": "2023-12-12T11:25:31.314Z" }, "descriptions": [ { "lang": "en", "value": "A vulnerability has been identified in SIMATIC PC-Station Plus (All versions), SIMATIC S7-400 CPU 412-2 PN V7 (All versions), SIMATIC S7-400 CPU 414-3 PN/DP V7 (All versions), SIMATIC S7-400 CPU 414F-3 PN/DP V7 (All versions), SIMATIC S7-400 CPU 416-3 PN/DP V7 (All versions), SIMATIC S7-400 CPU 416F-3 PN/DP V7 (All versions), SINAMICS S120 (incl. SIPLUS variants) (All versions < V5.2 SP3 HF15), SIPLUS S7-400 CPU 414-3 PN/DP V7 (All versions), SIPLUS S7-400 CPU 416-3 PN/DP V7 (All versions). The affected products do not handle HTTP(S) requests to the web server correctly.\r\n\r\nThis could allow an attacker to exhaust system resources and create a denial of service condition for the device." } ], "affected": [ { "vendor": "Siemens", "product": "SIMATIC PC-Station Plus", "versions": [ { "version": "All versions", "status": "affected" } ], "defaultStatus": "unknown" }, { "vendor": "Siemens", "product": "SIMATIC S7-400 CPU 412-2 PN V7", "versions": [ { "version": "All versions", "status": "affected" } ], "defaultStatus": "unknown" }, { "vendor": "Siemens", "product": "SIMATIC S7-400 CPU 414-3 PN/DP V7", "versions": [ { "version": "All versions", "status": "affected" } ], "defaultStatus": "unknown" }, { "vendor": "Siemens", "product": "SIMATIC S7-400 CPU 414F-3 PN/DP V7", "versions": [ { "version": "All versions", "status": "affected" } ], "defaultStatus": "unknown" }, { "vendor": "Siemens", "product": "SIMATIC S7-400 CPU 416-3 PN/DP V7", "versions": [ { "version": "All versions", "status": "affected" } ], "defaultStatus": "unknown" }, { "vendor": "Siemens", "product": "SIMATIC S7-400 CPU 416F-3 PN/DP V7", "versions": [ { "version": "All versions", "status": "affected" } ], "defaultStatus": "unknown" }, { "vendor": "Siemens", "product": "SINAMICS S120 (incl. SIPLUS variants)", "versions": [ { "version": "All versions < V5.2 SP3 HF15", "status": "affected" } ], "defaultStatus": "unknown" }, { "vendor": "Siemens", "product": "SIPLUS S7-400 CPU 414-3 PN/DP V7", "versions": [ { "version": "All versions", "status": "affected" } ], "defaultStatus": "unknown" }, { "vendor": "Siemens", "product": "SIPLUS S7-400 CPU 416-3 PN/DP V7", "versions": [ { "version": "All versions", "status": "affected" } ], "defaultStatus": "unknown" } ], "metrics": [ { "cvssV3_1": { "version": "3.1", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H/E:P/RL:O/RC:C", "baseScore": 7.5, "baseSeverity": "HIGH" } } ], "problemTypes": [ { "descriptions": [ { "lang": "en", "cweId": "CWE-674", "description": "CWE-674: Uncontrolled Recursion", "type": "CWE" } ] } ], "references": [ { "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-892915.pdf" } ] }, "adp": [ { "providerMetadata": { "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE", "dateUpdated": "2024-08-03T14:55:07.699Z" }, "title": "CVE Program Container", "references": [ { "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-892915.pdf", "tags": [ "x_transferred" ] } ] }, { "metrics": [ { "other": { "type": "ssvc", "content": { "id": "CVE-2022-47374", "role": "CISA Coordinator", "options": [ { "Exploitation": "none" }, { "Automatable": "yes" }, { "Technical Impact": "partial" } ], "version": "2.0.3", "timestamp": "2023-12-23T05:01:16.237841Z" } } } ], "title": "CISA ADP Vulnrichment", "providerMetadata": { "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "shortName": "CISA-ADP", "dateUpdated": "2026-02-25T16:34:35.793Z" } } ] } }