{ "dataType": "CVE_RECORD", "dataVersion": "5.1", "cveMetadata": { "cveId": "CVE-2022-47911", "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6", "state": "PUBLISHED", "assignerShortName": "icscert", "dateReserved": "2022-12-21T18:52:32.347Z", "datePublished": "2023-01-18T00:47:02.611Z", "dateUpdated": "2025-01-16T21:59:38.724Z" }, "containers": { "cna": { "affected": [ { "defaultStatus": "unaffected", "product": "RTLS Studio", "vendor": "Sewio", "versions": [ { "lessThanOrEqual": "2.6.2", "status": "affected", "version": "2.0.0", "versionType": "custom" } ] } ], "credits": [ { "lang": "en", "type": "reporter", "user": "00000000-0000-4000-9000-000000000000", "value": "Andrea Palanca of Nozomi Networks" } ], "datePublic": "2023-01-12T21:05:00.000Z", "descriptions": [ { "lang": "en", "supportingMedia": [ { "base64": false, "type": "text/html", "value": "
Sewio’s Real-Time Location System (RTLS) Studio version 2.0.0 up to and including version 2.6.2 does not properly validate the input module name to the backup services of the software. This could allow a remote attacker to access sensitive functions of the application and execute arbitrary system commands.
" } ], "value": "Sewio’s Real-Time Location System (RTLS) Studio version 2.0.0 up to and including version 2.6.2 does not properly validate the input module name to the backup services of the software. This could allow a remote attacker to access sensitive functions of the application and execute arbitrary system commands.\n\n" } ], "metrics": [ { "cvssV3_1": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 9.1, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "HIGH", "scope": "CHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:C/C:H/I:H/A:H", "version": "3.1" }, "format": "CVSS", "scenarios": [ { "lang": "en", "value": "GENERAL" } ] } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-78", "description": "CWE-78 Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6", "shortName": "icscert", "dateUpdated": "2023-01-18T00:47:02.611Z" }, "references": [ { "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-23-012-01" } ], "solutions": [ { "lang": "en", "supportingMedia": [ { "base64": false, "type": "text/html", "value": "\nSewio has provided the following updates and recommends that users update to the latest version:
\n\nSewio also recommends the following workarounds to reduce the risk of exploitation:
\n\n