{ "dataType": "CVE_RECORD", "dataVersion": "5.1", "cveMetadata": { "cveId": "CVE-2023-0811", "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6", "state": "PUBLISHED", "assignerShortName": "icscert", "dateReserved": "2023-02-13T15:41:55.590Z", "datePublished": "2023-03-16T17:41:25.525Z", "dateUpdated": "2025-01-16T21:42:32.824Z" }, "containers": { "cna": { "affected": [ { "defaultStatus": "unaffected", "packageName": "CJ2H-CPU6 □ -EIP", "product": "CJ1M SYSMAC CJ-series", "vendor": "Omron ", "versions": [ { "status": "affected", "version": "All versions " } ] }, { "defaultStatus": "unaffected", "packageName": "CJ2H-CPU6 □", "product": "CJ1M SYSMAC CJ-series", "vendor": "Omron", "versions": [ { "status": "affected", "version": "All versions " } ] }, { "defaultStatus": "unaffected", "packageName": "CJ2M-CPU □ □", "product": "CJ1M SYSMAC CJ-series", "vendor": "Omron", "versions": [ { "status": "affected", "version": "All versions " } ] }, { "defaultStatus": "unaffected", "packageName": "CJ1G-CPU □ □ P", "product": "CJ1M SYSMAC CJ-series", "vendor": "Omron", "versions": [ { "status": "affected", "version": "All versions " } ] }, { "defaultStatus": "unaffected", "packageName": "CS1H-CPU □ □ H", "product": "CJ1M SYSMAC CS-series ", "vendor": "Omron ", "versions": [ { "status": "affected", "version": "All versions " } ] }, { "defaultStatus": "unaffected", "packageName": "CS1G-CPU □ □ H", "product": "CJ1M SYSMAC CS-series ", "vendor": "Omron ", "versions": [ { "status": "affected", "version": "All versions " } ] }, { "defaultStatus": "unaffected", "packageName": "CS1D-CPU □ □ HA", "product": "CJ1M SYSMAC CS-series ", "vendor": "Omron ", "versions": [ { "status": "affected", "version": "All versions " } ] }, { "defaultStatus": "unaffected", "packageName": "CS1D-CPU □ □ H", "product": "CJ1M SYSMAC CS-series ", "vendor": "Omron ", "versions": [ { "status": "affected", "version": "All versions " } ] }, { "defaultStatus": "unaffected", "packageName": "CS1D-CPU □ □ SA", "product": "CJ1M SYSMAC CS-series ", "vendor": "Omron", "versions": [ { "status": "affected", "version": "All versions " } ] }, { "defaultStatus": "unaffected", "packageName": "CS1D-CPU □ □ S", "product": "CJ1M SYSMAC CS-series ", "vendor": "Omron ", "versions": [ { "status": "affected", "version": "All versions " } ] }, { "defaultStatus": "unaffected", "packageName": "CS1D-CPU □ □ P", "product": "CJ1M SYSMAC CS-series ", "vendor": "Omron ", "versions": [ { "status": "affected", "version": "All versions " } ] }, { "defaultStatus": "unaffected", "packageName": "CP2E-E □ □ D □ - □", "product": "CJ1M SYSMAC CP-series", "vendor": "Omron", "versions": [ { "status": "affected", "version": "All versions " } ] }, { "defaultStatus": "unaffected", "packageName": "CP2E-S □ □ D □- □", "product": "CJ1M SYSMAC CP-series", "vendor": "Omron", "versions": [ { "status": "affected", "version": "All versions " } ] }, { "defaultStatus": "unaffected", "packageName": "CP2E-N □ □ D □ - □", "product": "CJ1M SYSMAC CP-series", "vendor": "Omron", "versions": [ { "status": "affected", "version": "All versions " } ] }, { "defaultStatus": "unaffected", "packageName": "CP1H-X40D □ - □", "product": "CJ1M SYSMAC CP-series", "vendor": "Omron", "versions": [ { "status": "affected", "version": "All versions " } ] }, { "defaultStatus": "unaffected", "packageName": "CP1H-XA40D □ - □", "product": "CJ1M SYSMAC CP-series", "vendor": "Omron", "versions": [ { "status": "affected", "version": "All versions " } ] }, { "defaultStatus": "unaffected", "packageName": "CP1H-Y20DT-D", "product": "CJ1M SYSMAC CP-series", "vendor": "Omron", "versions": [ { "status": "affected", "version": "All versions " } ] }, { "defaultStatus": "unaffected", "packageName": "CP1L-EL20D □ - □", "product": "CJ1M SYSMAC CP-series", "vendor": "Omron", "versions": [ { "status": "affected", "version": "All versions " } ] }, { "defaultStatus": "unaffected", "packageName": "CP1L-EM □ □ D □ - □", "product": "CJ1M SYSMAC CP-series", "vendor": "Omron", "versions": [ { "status": "affected", "version": "All versions " } ] }, { "defaultStatus": "unaffected", "packageName": "CP1L-L □ □ D □- □", "product": "CJ1M SYSMAC CP-series", "vendor": "Omron", "versions": [ { "status": "affected", "version": "All versions " } ] }, { "defaultStatus": "unaffected", "packageName": "CP1L-M □ □ D □ - □", "product": "CJ1M SYSMAC CP-series", "vendor": "Omron", "versions": [ { "status": "affected", "version": "All versions " } ] }, { "defaultStatus": "unaffected", "packageName": "CP1E-E □ □ D □ - □", "product": "CJ1M SYSMAC CP-series", "vendor": "Omron", "versions": [ { "status": "affected", "version": "All versions " } ] }, { "defaultStatus": "unaffected", "packageName": "CP1E-NA □ □ D □ - □", "product": "CJ1M SYSMAC CP-series", "vendor": "Omron", "versions": [ { "status": "affected", "version": "All versions " } ] } ], "credits": [ { "lang": "en", "type": "finder", "user": "00000000-0000-4000-9000-000000000000", "value": "Sam Hanson of Dragos reported these vulnerabilities to CISA. " } ], "descriptions": [ { "lang": "en", "supportingMedia": [ { "base64": false, "type": "text/html", "value": "\n\nOmron CJ1M unit v4.0 and prior has improper access controls on the memory region where the UM password is stored. If an adversary issues a PROGRAM AREA WRITE command to a specific memory region, they could overwrite the password. This may lead to disabling UM protections or setting a non-ASCII password (non-keyboard characters) and preventing an engineer from viewing or modifying the user program. \n\n" } ], "value": "\nOmron CJ1M unit v4.0 and prior has improper access controls on the memory region where the UM password is stored. If an adversary issues a PROGRAM AREA WRITE command to a specific memory region, they could overwrite the password. This may lead to disabling UM protections or setting a non-ASCII password (non-keyboard characters) and preventing an engineer from viewing or modifying the user program. \n\n" } ], "metrics": [ { "cvssV3_1": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 9.1, "baseSeverity": "CRITICAL", "confidentialityImpact": "NONE", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:H/A:H", "version": "3.1" }, "format": "CVSS", "scenarios": [ { "lang": "en", "value": "GENERAL" } ] } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-284", "description": "CWE-284 Improper Access Control ", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6", "shortName": "icscert", "dateUpdated": "2023-03-16T17:45:14.919Z" }, "references": [ { "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-23-073-01" }, { "url": "https://www.ia.omron.com/product/vulnerability/OMSR-2023-001_en.pdf" } ], "source": { "discovery": "UNKNOWN" }, "workarounds": [ { "lang": "en", "supportingMedia": [ { "base64": false, "type": "text/html", "value": "\n\n
OMRON has released the following countermeasures for users to implement:
If the countermeasures cannot be applied, OMRON recommends that customers take the following mitigation measures:
Security measures to prevent unauthorized access:
For more information, see Omron’s Security Advisory.