{ "dataType": "CVE_RECORD", "dataVersion": "5.1", "cveMetadata": { "state": "PUBLISHED", "cveId": "CVE-2023-22610", "assignerOrgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb", "assignerShortName": "schneider", "dateUpdated": "2025-02-05T20:06:58.944Z", "dateReserved": "2023-01-04T00:00:00.000Z", "datePublished": "2023-01-31T00:00:00.000Z" }, "containers": { "cna": { "affected": [ { "defaultStatus": "unaffected", "product": "EcoStruxure Geo SCADA Expert 2019 - 2021 (formerly known as ClearSCADA)", "vendor": "Schneider Electric", "versions": [ { "lessThan": "October 2022", "status": "affected", "version": "All", "versionType": "custom" } ] } ], "descriptions": [ { "lang": "en", "supportingMedia": [ { "base64": false, "type": "text/html", "value": "

\n\nA CWE-863: Incorrect Authorization vulnerability exists that could cause Denial of\nService against the Geo SCADA server when specific messages are sent to the server over the\ndatabase server TCP port. \n\n

" } ], "value": "\nA CWE-863: Incorrect Authorization vulnerability exists that could cause Denial of\nService against the Geo SCADA server when specific messages are sent to the server over the\ndatabase server TCP port. \n\n\n\n" } ], "metrics": [ { "cvssV3_1": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 9.1, "baseSeverity": "CRITICAL", "confidentialityImpact": "NONE", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:H/A:H", "version": "3.1" }, "format": "CVSS", "scenarios": [ { "lang": "en", "value": "GENERAL" } ] } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-863", "description": "CWE-863 Incorrect Authorization", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "orgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb", "shortName": "schneider", "dateUpdated": "2023-06-14T07:17:44.658Z" }, "references": [ { "url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2023-010-02&p_enDocType=Security+and+Safety+Notice&p_File_Name=SEVD-2023-010-02_Geo_SCADA_Security_Notification.pdf" } ], "source": { "discovery": "UNKNOWN" }, "x_generator": { "engine": "Vulnogram 0.0.9" } }, "adp": [ { "providerMetadata": { "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE", "dateUpdated": "2024-08-02T10:13:49.385Z" }, "title": "CVE Program Container", "references": [ { "url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2023-010-02&p_enDocType=Security+and+Safety+Notice&p_File_Name=SEVD-2023-010-02_Geo_SCADA_Security_Notification.pdf", "tags": [ "x_transferred" ] } ] }, { "metrics": [ { "other": { "type": "ssvc", "content": { "timestamp": "2025-02-05T19:55:02.779459Z", "id": "CVE-2023-22610", "options": [ { "Exploitation": "none" }, { "Automatable": "yes" }, { "Technical Impact": "partial" } ], "role": "CISA Coordinator", "version": "2.0.3" } } } ], "title": "CISA ADP Vulnrichment", "providerMetadata": { "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "shortName": "CISA-ADP", "dateUpdated": "2025-02-05T20:06:58.944Z" } } ] } }