{ "dataType": "CVE_RECORD", "dataVersion": "5.1", "cveMetadata": { "cveId": "CVE-2023-34316", "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6", "state": "PUBLISHED", "assignerShortName": "icscert", "dateReserved": "2023-06-06T14:32:07.393Z", "datePublished": "2023-07-10T19:01:51.280Z", "dateUpdated": "2025-01-27T16:20:03.560Z" }, "containers": { "cna": { "affected": [ { "defaultStatus": "unaffected", "product": "Infrasuite Device Master", "vendor": "Delta Electronics", "versions": [ { "lessThan": "v1.0.7", "status": "affected", "version": "0", "versionType": "custom" } ] } ], "credits": [ { "lang": "en", "type": "finder", "user": "00000000-0000-4000-9000-000000000000", "value": "​Piotr Bazydlo of Trend Micro’s Zero Day Initiative reported these vulnerabilities to CISA." } ], "datePublic": "2023-06-29T17:00:00.000Z", "descriptions": [ { "lang": "en", "supportingMedia": [ { "base64": false, "type": "text/html", "value": "​An attacker could bypass the latest Delta Electronics InfraSuite Device Master (versions prior to 1.0.7) patch, which could allow an attacker to retrieve file contents." } ], "value": "​An attacker could bypass the latest Delta Electronics InfraSuite Device Master (versions prior to 1.0.7) patch, which could allow an attacker to retrieve file contents." } ], "metrics": [ { "cvssV3_1": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "NONE", "baseScore": 6.5, "baseSeverity": "MEDIUM", "confidentialityImpact": "HIGH", "integrityImpact": "NONE", "privilegesRequired": "LOW", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:N/A:N", "version": "3.1" }, "format": "CVSS", "scenarios": [ { "lang": "en", "value": "GENERAL" } ] } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-552", "description": "CWE-552 Files or Directories Accessible to External Parties", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6", "shortName": "icscert", "dateUpdated": "2025-01-27T16:20:03.560Z" }, "references": [ { "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-23-180-01" } ], "solutions": [ { "lang": "en", "supportingMedia": [ { "base64": false, "type": "text/html", "value": "

​Delta Electronics has provided a fix to these vulnerabilities. Users are encouraged to update to the latest version.

" } ], "value": "​Delta Electronics has provided a fix to these vulnerabilities. Users are encouraged to update to the latest version.\n\n * ​Delta Electronics InfraSuite Device Master: Update to v1.0.7 https://datacenter-softwarecenter.deltaww.com/Download/UPS/Software/InfraSuite_Device_Master_1.0.7(x64).exe ." } ], "source": { "advisory": "ICSA-23-180-01", "discovery": "EXTERNAL" }, "title": "Delta Electronics InfraSuite Device Master Improper Access Control", "x_generator": { "engine": "Vulnogram 0.1.0-dev" } }, "adp": [ { "providerMetadata": { "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE", "dateUpdated": "2024-08-02T16:10:06.493Z" }, "title": "CVE Program Container", "references": [ { "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-23-180-01", "tags": [ "x_transferred" ] } ] }, { "metrics": [ { "other": { "type": "ssvc", "content": { "timestamp": "2024-10-23T17:57:29.955732Z", "id": "CVE-2023-34316", "options": [ { "Exploitation": "none" }, { "Automatable": "no" }, { "Technical Impact": "partial" } ], "role": "CISA Coordinator", "version": "2.0.3" } } } ], "title": "CISA ADP Vulnrichment", "providerMetadata": { "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "shortName": "CISA-ADP", "dateUpdated": "2024-10-23T17:59:29.374Z" } } ] } }