{ "dataType": "CVE_RECORD", "dataVersion": "5.1", "cveMetadata": { "cveId": "CVE-2023-34347", "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6", "state": "PUBLISHED", "assignerShortName": "icscert", "dateReserved": "2023-06-06T14:32:07.383Z", "datePublished": "2023-07-10T18:59:30.158Z", "dateUpdated": "2024-11-08T17:43:56.320Z" }, "containers": { "cna": { "affected": [ { "defaultStatus": "unaffected", "product": "Infrasuite Device Master", "vendor": "Delta Electronics", "versions": [ { "lessThan": "v1.0.7", "status": "affected", "version": "0", "versionType": "custom" } ] } ], "credits": [ { "lang": "en", "type": "finder", "user": "00000000-0000-4000-9000-000000000000", "value": "​Piotr Bazydlo (@chudypb) of Trend Micro’s Zero Day Initiative reported these vulnerabilities to CISA." } ], "datePublic": "2023-06-29T17:00:00.000Z", "descriptions": [ { "lang": "en", "supportingMedia": [ { "base64": false, "type": "text/html", "value": "\n\n\n\n​Delta Electronics InfraSuite Device Master versions prior to 1.0.7 contains classes that cannot be deserialized, which could allow an attack to remotely execute arbitrary code. \n\n\n\n" } ], "value": "\n\n\n​Delta Electronics InfraSuite Device Master versions prior to 1.0.7 contains classes that cannot be deserialized, which could allow an attack to remotely execute arbitrary code. \n\n\n\n" } ], "metrics": [ { "cvssV3_1": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 9.8, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, "format": "CVSS", "scenarios": [ { "lang": "en", "value": "GENERAL" } ] } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-502", "description": "CWE-502 Deserialization of Untrusted Data", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6", "shortName": "icscert", "dateUpdated": "2023-07-10T18:59:30.158Z" }, "references": [ { "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-23-180-01" } ], "solutions": [ { "lang": "en", "supportingMedia": [ { "base64": false, "type": "text/html", "value": "\n\n

​Delta Electronics has provided a fix to these vulnerabilities. Users are encouraged to update to the latest version.

" } ], "value": "\n​Delta Electronics has provided a fix to these vulnerabilities. Users are encouraged to update to the latest version.\n\n * ​Delta Electronics InfraSuite Device Master: Update to v1.0.7 https://datacenter-softwarecenter.deltaww.com/Download/UPS/Software/InfraSuite_Device_Master_1.0.7(x64).exe .\n\n\n" } ], "source": { "advisory": "ICSA-23-180-01", "discovery": "EXTERNAL" }, "title": "​Delta Electronics InfraSuite Device Master Deserialization of Untrusted Data", "x_generator": { "engine": "Vulnogram 0.1.0-dev" } }, "adp": [ { "providerMetadata": { "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE", "dateUpdated": "2024-08-02T16:10:06.428Z" }, "title": "CVE Program Container", "references": [ { "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-23-180-01", "tags": [ "x_transferred" ] } ] }, { "metrics": [ { "other": { "type": "ssvc", "content": { "timestamp": "2024-11-08T17:43:47.191964Z", "id": "CVE-2023-34347", "options": [ { "Exploitation": "none" }, { "Automatable": "yes" }, { "Technical Impact": "total" } ], "role": "CISA Coordinator", "version": "2.0.3" } } } ], "title": "CISA ADP Vulnrichment", "providerMetadata": { "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "shortName": "CISA-ADP", "dateUpdated": "2024-11-08T17:43:56.320Z" } } ] } }