{ "dataType": "CVE_RECORD", "dataVersion": "5.2", "cveMetadata": { "cveId": "CVE-2023-35699", "assignerOrgId": "a6863dd2-93fc-443d-bef1-79f0b5020988", "state": "PUBLISHED", "assignerShortName": "SICK AG", "dateReserved": "2023-06-15T11:32:19.767Z", "datePublished": "2023-07-10T09:39:45.804Z", "dateUpdated": "2026-06-01T12:10:16.255Z" }, "containers": { "cna": { "providerMetadata": { "orgId": "a6863dd2-93fc-443d-bef1-79f0b5020988", "shortName": "SICK AG", "dateUpdated": "2026-06-01T12:10:16.255Z" }, "problemTypes": [ { "descriptions": [ { "lang": "en", "cweId": "CWE-313", "description": "CWE-313 Cleartext Storage in a File or on Disk", "type": "CWE" } ] } ], "affected": [ { "vendor": "SICK AG", "product": "ICR890-4", "versions": [ { "status": "affected", "version": "0", "lessThan": "2.5.0", "versionType": "*" } ], "defaultStatus": "affected" } ], "descriptions": [ { "lang": "en", "value": "Cleartext Storage on Disk in the SICK ICR890-4 could allow an unauthenticated attacker with local access to the device to disclose sensitive information by accessing a SD card.", "supportingMedia": [ { "type": "text/html", "base64": false, "value": "Cleartext Storage on Disk in the SICK ICR890-4 could allow an unauthenticated attacker with local access to the device to disclose sensitive information by accessing a SD card." } ] } ], "references": [ { "url": "https://sick.com/psirt", "tags": [ "issue-tracking" ] }, { "url": "https://sick.com/.well-known/csaf/white/2023/sca-2023-0006.pdf", "tags": [ "vendor-advisory" ] }, { "url": "https://sick.com/.well-known/csaf/white/2023/sca-2023-0006.json", "tags": [ "x_csaf" ] } ], "metrics": [ { "format": "CVSS", "scenarios": [ { "lang": "en", "value": "GENERAL" } ], "cvssV3_1": { "version": "3.1", "attackVector": "PHYSICAL", "attackComplexity": "LOW", "privilegesRequired": "NONE", "userInteraction": "NONE", "scope": "CHANGED", "confidentialityImpact": "HIGH", "integrityImpact": "NONE", "availabilityImpact": "NONE", "baseSeverity": "MEDIUM", "baseScore": 5.3, "vectorString": "CVSS:3.1/AV:P/AC:L/PR:N/UI:N/S:C/C:H/I:N/A:N" } } ], "workarounds": [ { "lang": "en", "value": "Please make sure that you apply general security practices when operating the SICK ICR890-\n4 like restricting physical access to the device. The following general security practices could mitigate\nthe associated security risk.", "supportingMedia": [ { "type": "text/html", "base64": false, "value": "Please make sure that you apply general security practices when operating the SICK ICR890-\n4 like restricting physical access to the device. The following general security practices could mitigate\nthe associated security risk.\n\n\n
" } ] } ], "source": { "discovery": "INTERNAL" }, "x_generator": { "engine": "Vulnogram 0.1.0-dev" } }, "adp": [ { "providerMetadata": { "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE", "dateUpdated": "2024-08-02T16:30:44.141Z" }, "title": "CVE Program Container", "references": [ { "tags": [ "issue-tracking", "x_transferred" ], "url": "https://sick.com/psirt" }, { "tags": [ "vendor-advisory", "x_transferred" ], "url": "https://sick.com/.well-known/csaf/white/2023/sca-2023-0006.pdf" }, { "tags": [ "x_csaf", "x_transferred" ], "url": "https://sick.com/.well-known/csaf/white/2023/sca-2023-0006.json" } ] }, { "metrics": [ { "other": { "type": "ssvc", "content": { "timestamp": "2024-10-25T19:50:31.404610Z", "id": "CVE-2023-35699", "options": [ { "Exploitation": "none" }, { "Automatable": "no" }, { "Technical Impact": "partial" } ], "role": "CISA Coordinator", "version": "2.0.3" } } } ], "title": "CISA ADP Vulnrichment", "providerMetadata": { "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "shortName": "CISA-ADP", "dateUpdated": "2024-10-25T19:51:39.248Z" } } ] } }