{ "dataType": "CVE_RECORD", "dataVersion": "5.1", "cveMetadata": { "cveId": "CVE-2023-35921", "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77", "state": "PUBLISHED", "assignerShortName": "siemens", "dateReserved": "2023-06-20T10:46:34.162Z", "datePublished": "2023-07-11T09:07:09.314Z", "dateUpdated": "2024-11-13T14:28:33.242Z" }, "containers": { "cna": { "providerMetadata": { "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77", "shortName": "siemens", "dateUpdated": "2023-07-11T09:07:09.314Z" }, "descriptions": [ { "lang": "en", "value": "A vulnerability has been identified in SIMATIC MV540 H (All versions < V3.3.4), SIMATIC MV540 S (All versions < V3.3.4), SIMATIC MV550 H (All versions < V3.3.4), SIMATIC MV550 S (All versions < V3.3.4), SIMATIC MV560 U (All versions < V3.3.4), SIMATIC MV560 X (All versions < V3.3.4). Affected devices cannot properly process specially crafted Ethernet frames sent to the devices. This could allow an unauthenticated remote attacker to cause a denial of service condition. The affected devices must be restarted manually." } ], "affected": [ { "vendor": "Siemens", "product": "SIMATIC MV540 H", "versions": [ { "version": "All versions < V3.3.4", "status": "affected" } ], "defaultStatus": "unknown" }, { "vendor": "Siemens", "product": "SIMATIC MV540 S", "versions": [ { "version": "All versions < V3.3.4", "status": "affected" } ], "defaultStatus": "unknown" }, { "vendor": "Siemens", "product": "SIMATIC MV550 H", "versions": [ { "version": "All versions < V3.3.4", "status": "affected" } ], "defaultStatus": "unknown" }, { "vendor": "Siemens", "product": "SIMATIC MV550 S", "versions": [ { "version": "All versions < V3.3.4", "status": "affected" } ], "defaultStatus": "unknown" }, { "vendor": "Siemens", "product": "SIMATIC MV560 U", "versions": [ { "version": "All versions < V3.3.4", "status": "affected" } ], "defaultStatus": "unknown" }, { "vendor": "Siemens", "product": "SIMATIC MV560 X", "versions": [ { "version": "All versions < V3.3.4", "status": "affected" } ], "defaultStatus": "unknown" } ], "metrics": [ { "cvssV3_1": { "version": "3.1", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H/E:P/RL:O/RC:C", "baseScore": 7.5, "baseSeverity": "HIGH" } } ], "problemTypes": [ { "descriptions": [ { "lang": "en", "cweId": "CWE-400", "description": "CWE-400: Uncontrolled Resource Consumption", "type": "CWE" } ] } ], "references": [ { "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-561322.pdf" } ] }, "adp": [ { "providerMetadata": { "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE", "dateUpdated": "2024-08-02T16:37:40.422Z" }, "title": "CVE Program Container", "references": [ { "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-561322.pdf", "tags": [ "x_transferred" ] } ] }, { "affected": [ { "vendor": "siemens", "product": "simatic_mv540_h", "cpes": [ "cpe:2.3:h:siemens:simatic_mv540_h:-:*:*:*:*:*:*:*" ], "defaultStatus": "unaffected", "versions": [ { "version": "0", "status": "affected", "lessThan": "V3.3.4", "versionType": "custom" } ] }, { "vendor": "siemens", "product": "simatic_mv540_s", "cpes": [ "cpe:2.3:h:siemens:simatic_mv540_s:-:*:*:*:*:*:*:*" ], "defaultStatus": "unaffected", "versions": [ { "version": "0", "status": "affected", "lessThan": "V3.3.4", "versionType": "custom" } ] }, { "vendor": "siemens", "product": "simatic_mv550_h", "cpes": [ "cpe:2.3:h:siemens:simatic_mv550_h:-:*:*:*:*:*:*:*" ], "defaultStatus": "unaffected", "versions": [ { "version": "0", "status": "affected", "lessThan": "V3.3.4", "versionType": "custom" } ] }, { "vendor": "siemens", "product": "simatic_mv550_s", "cpes": [ "cpe:2.3:h:siemens:simatic_mv550_s:-:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "versions": [ { "version": "0", "status": "affected", "lessThan": "V3.3.4", "versionType": "custom" } ] }, { "vendor": "siemens", "product": "simatic_mv560_u", "cpes": [ "cpe:2.3:h:siemens:simatic_mv560_u:-:*:*:*:*:*:*:*" ], "defaultStatus": "unaffected", "versions": [ { "version": "0", "status": "affected", "lessThan": "V3.3.4", "versionType": "custom" } ] }, { "vendor": "siemens", "product": "simatic_mv560_x", "cpes": [ "cpe:2.3:h:siemens:simatic_mv560_x:-:*:*:*:*:*:*:*" ], "defaultStatus": "unaffected", "versions": [ { "version": "0", "status": "affected", "lessThan": "V3.3.4", "versionType": "custom" } ] } ], "metrics": [ { "other": { "type": "ssvc", "content": { "timestamp": "2024-11-13T14:25:45.446014Z", "id": "CVE-2023-35921", "options": [ { "Exploitation": "none" }, { "Automatable": "yes" }, { "Technical Impact": "partial" } ], "role": "CISA Coordinator", "version": "2.0.3" } } } ], "title": "CISA ADP Vulnrichment", "providerMetadata": { "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "shortName": "CISA-ADP", "dateUpdated": "2024-11-13T14:28:33.242Z" } } ] } }