{ "dataType": "CVE_RECORD", "dataVersion": "5.1", "cveMetadata": { "cveId": "CVE-2023-4291", "assignerOrgId": "270ccfa6-a436-4e77-922e-914ec3a9685c", "state": "PUBLISHED", "assignerShortName": "CERTVDE", "dateReserved": "2023-08-10T12:30:45.947Z", "datePublished": "2023-09-21T06:17:57.646Z", "dateUpdated": "2024-09-24T16:16:55.237Z" }, "containers": { "cna": { "affected": [ { "defaultStatus": "unaffected", "product": "FDS101 for FAdC/FAdCi", "vendor": "Frauscher", "versions": [ { "lessThanOrEqual": "1.4.24", "status": "affected", "version": "0", "versionType": "semver" } ] } ], "datePublic": "2023-09-21T06:00:00.000Z", "descriptions": [ { "lang": "en", "supportingMedia": [ { "base64": false, "type": "text/html", "value": "
Frauscher Sensortechnik GmbH FDS101 for FAdC/FAdCi v1.4.24 and all previous versions are vulnerable to a remote code execution (RCE) vulnerability via manipulated parameters of the web interface without authentication. This could lead to a full compromise of the FDS101 device.

" } ], "value": "Frauscher Sensortechnik GmbH FDS101 for FAdC/FAdCi v1.4.24 and all previous versions are vulnerable to a remote code execution (RCE) vulnerability via manipulated parameters of the web interface without authentication. This could lead to a full compromise of the FDS101 device.\n\n\n" } ], "metrics": [ { "cvssV3_1": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 9.8, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, "format": "CVSS", "scenarios": [ { "lang": "en", "value": "GENERAL" } ] } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-94", "description": "CWE-94 Improper Control of Generation of Code ('Code Injection')", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "orgId": "270ccfa6-a436-4e77-922e-914ec3a9685c", "shortName": "CERTVDE", "dateUpdated": "2023-09-21T06:17:57.646Z" }, "references": [ { "url": "https://cert.vde.com/en/advisories/VDE-2023-038" } ], "source": { "discovery": "UNKNOWN" }, "title": "Frauscher FDS101 for FAdC/FAdCi remote code execution vulnerability", "x_generator": { "engine": "Vulnogram 0.1.0-dev" } }, "adp": [ { "providerMetadata": { "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE", "dateUpdated": "2024-08-02T07:24:04.644Z" }, "title": "CVE Program Container", "references": [ { "url": "https://cert.vde.com/en/advisories/VDE-2023-038", "tags": [ "x_transferred" ] } ] }, { "affected": [ { "vendor": "frauscher", "product": "frauscher_diagnostic_system_101", "cpes": [ "cpe:2.3:a:frauscher:frauscher_diagnostic_system_101:-:*:*:*:*:fadc:*:*" ], "defaultStatus": "unknown", "versions": [ { "version": "0", "status": "affected", "lessThanOrEqual": "1.4.24", "versionType": "custom" } ] }, { "vendor": "frauscher", "product": "frauscher_diagnostic_system_101", "cpes": [ "cpe:2.3:a:frauscher:frauscher_diagnostic_system_101:-:*:*:*:*:fadci:*:*" ], "defaultStatus": "unknown", "versions": [ { "version": "0", "status": "affected", "lessThanOrEqual": "1.4.24", "versionType": "custom" } ] } ], "metrics": [ { "other": { "type": "ssvc", "content": { "timestamp": "2024-09-24T15:45:35.351295Z", "id": "CVE-2023-4291", "options": [ { "Exploitation": "none" }, { "Automatable": "yes" }, { "Technical Impact": "total" } ], "role": "CISA Coordinator", "version": "2.0.3" } } } ], "title": "CISA ADP Vulnrichment", "providerMetadata": { "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "shortName": "CISA-ADP", "dateUpdated": "2024-09-24T16:16:55.237Z" } } ] } }