{ "dataType": "CVE_RECORD", "dataVersion": "5.1", "cveMetadata": { "cveId": "CVE-2023-4485", "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6", "state": "PUBLISHED", "assignerShortName": "icscert", "dateReserved": "2023-08-22T17:40:08.822Z", "datePublished": "2023-09-05T23:03:57.616Z", "dateUpdated": "2025-01-16T21:30:24.611Z" }, "containers": { "cna": { "affected": [ { "defaultStatus": "unaffected", "product": "Sistemas SCADA", "vendor": "ARDEREG", "versions": [ { "lessThanOrEqual": "2.203", "status": "affected", "version": "0", "versionType": "custom" } ] } ], "credits": [ { "lang": "en", "type": "finder", "user": "00000000-0000-4000-9000-000000000000", "value": "Momen Eldawakhly of Samurai Digital Security Ltd. reported this vulnerability to CISA." } ], "datePublic": "2023-08-31T17:00:00.000Z", "descriptions": [ { "lang": "en", "supportingMedia": [ { "base64": false, "type": "text/html", "value": "ARDEREG Sistema SCADA Central versions 2.203 and prior\nlogin page are vulnerable to an unauthenticated blind SQL injection attack. An attacker could manipulate the application's SQL query logic to extract sensitive information or perform unauthorized actions within the database. In this case, the vulnerability could allow an attacker to execute arbitrary SQL queries through the login page, potentially leading to unauthorized access, data leakage, or even disruption of critical industrial processes.\n\n" } ], "value": "ARDEREG Sistema SCADA Central versions 2.203 and prior\nlogin page are vulnerable to an unauthenticated blind SQL injection attack. An attacker could manipulate the application's SQL query logic to extract sensitive information or perform unauthorized actions within the database. In this case, the vulnerability could allow an attacker to execute arbitrary SQL queries through the login page, potentially leading to unauthorized access, data leakage, or even disruption of critical industrial processes.\n\n" } ], "metrics": [ { "cvssV3_1": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 9.8, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, "format": "CVSS", "scenarios": [ { "lang": "en", "value": "GENERAL" } ] } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-89", "description": "CWE-89 SQL Injection", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6", "shortName": "icscert", "dateUpdated": "2023-09-05T23:03:57.616Z" }, "references": [ { "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-23-243-01" } ], "source": { "advisory": "ICSA-23-243-01", "discovery": "EXTERNAL" }, "title": "ARDEREG Sistemas SCADA SQL Injection", "workarounds": [ { "lang": "en", "supportingMedia": [ { "base64": false, "type": "text/html", "value": "\n\n\n\n
ARDEREG is aware of the issue. For more information, contact ARDEREG by email.
ARDEREG recommends the following workarounds to help reduce the risk:
\n\n