{ "dataType": "CVE_RECORD", "dataVersion": "5.1", "cveMetadata": { "cveId": "CVE-2024-10434", "assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5", "state": "PUBLISHED", "assignerShortName": "VulDB", "dateReserved": "2024-10-27T07:21:32.313Z", "datePublished": "2024-10-28T00:31:05.947Z", "dateUpdated": "2024-10-28T13:00:50.500Z" }, "containers": { "cna": { "providerMetadata": { "orgId": "1af790b2-7ee1-4545-860a-a788eba489b5", "shortName": "VulDB", "dateUpdated": "2024-10-28T00:31:05.947Z" }, "title": "Tenda AC1206 ate ate_Tenda_mfg_check_usb3 stack-based overflow", "problemTypes": [ { "descriptions": [ { "type": "CWE", "cweId": "CWE-121", "lang": "en", "description": "Stack-based Buffer Overflow" } ] } ], "affected": [ { "vendor": "Tenda", "product": "AC1206", "versions": [ { "version": "20241027", "status": "affected" } ] } ], "descriptions": [ { "lang": "en", "value": "A vulnerability was found in Tenda AC1206 up to 20241027. It has been classified as critical. This affects the function ate_Tenda_mfg_check_usb/ate_Tenda_mfg_check_usb3 of the file /goform/ate. The manipulation of the argument arg leads to stack-based buffer overflow. It is possible to initiate the attack remotely. The exploit has been disclosed to the public and may be used." }, { "lang": "de", "value": "Es wurde eine Schwachstelle in Tenda AC1206 bis 20241027 ausgemacht. Sie wurde als kritisch eingestuft. Es betrifft die Funktion ate_Tenda_mfg_check_usb/ate_Tenda_mfg_check_usb3 der Datei /goform/ate. Dank der Manipulation des Arguments arg mit unbekannten Daten kann eine stack-based buffer overflow-Schwachstelle ausgenutzt werden. Der Angriff kann über das Netzwerk erfolgen. Der Exploit steht zur öffentlichen Verfügung." } ], "metrics": [ { "cvssV4_0": { "version": "4.0", "baseScore": 8.7, "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N", "baseSeverity": "HIGH" } }, { "cvssV3_1": { "version": "3.1", "baseScore": 8.8, "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H", "baseSeverity": "HIGH" } }, { "cvssV3_0": { "version": "3.0", "baseScore": 8.8, "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H", "baseSeverity": "HIGH" } }, { "cvssV2_0": { "version": "2.0", "baseScore": 9, "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C" } } ], "timeline": [ { "time": "2024-10-27T00:00:00.000Z", "lang": "en", "value": "Advisory disclosed" }, { "time": "2024-10-27T02:00:00.000Z", "lang": "en", "value": "VulDB entry created" }, { "time": "2024-10-27T08:26:44.000Z", "lang": "en", "value": "VulDB entry last update" } ], "credits": [ { "lang": "en", "value": "physicszq (VulDB User)", "type": "reporter" } ], "references": [ { "url": "https://vuldb.com/?id.281985", "name": "VDB-281985 | Tenda AC1206 ate ate_Tenda_mfg_check_usb3 stack-based overflow", "tags": [ "vdb-entry", "technical-description" ] }, { "url": "https://vuldb.com/?ctiid.281985", "name": "VDB-281985 | CTI Indicators (IOB, IOC, IOA)", "tags": [ "signature", "permissions-required" ] }, { "url": "https://vuldb.com/?submit.431291", "name": "Submit #431291 | tenda tenda router AC1206 Buffer Overflow", "tags": [ "third-party-advisory" ] }, { "url": "https://github.com/physicszq/Routers/blob/main/Tenda/README.md", "tags": [ "exploit" ] }, { "url": "https://www.tenda.com.cn/", "tags": [ "product" ] } ] }, "adp": [ { "affected": [ { "vendor": "tenda", "product": "ac1206", "cpes": [ "cpe:2.3:h:tenda:ac1206:-:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "versions": [ { "version": "20241027", "status": "affected" } ] } ], "metrics": [ { "other": { "type": "ssvc", "content": { "timestamp": "2024-10-28T12:59:43.912430Z", "id": "CVE-2024-10434", "options": [ { "Exploitation": "poc" }, { "Automatable": "no" }, { "Technical Impact": "total" } ], "role": "CISA Coordinator", "version": "2.0.3" } } } ], "title": "CISA ADP Vulnrichment", "providerMetadata": { "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "shortName": "CISA-ADP", "dateUpdated": "2024-10-28T13:00:50.500Z" } } ] } }