{ "dataType": "CVE_RECORD", "dataVersion": "5.1", "cveMetadata": { "cveId": "CVE-2024-10750", "assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5", "state": "PUBLISHED", "assignerShortName": "VulDB", "dateReserved": "2024-11-03T06:35:17.315Z", "datePublished": "2024-11-04T01:00:07.611Z", "dateUpdated": "2024-11-05T14:55:33.301Z" }, "containers": { "cna": { "providerMetadata": { "orgId": "1af790b2-7ee1-4545-860a-a788eba489b5", "shortName": "VulDB", "dateUpdated": "2024-11-04T01:00:07.611Z" }, "title": "Tenda i22 SysToo websReadEvent null pointer dereference", "problemTypes": [ { "descriptions": [ { "type": "CWE", "cweId": "CWE-476", "lang": "en", "description": "NULL Pointer Dereference" } ] } ], "affected": [ { "vendor": "Tenda", "product": "i22", "versions": [ { "version": "1.0.0.3(4687)", "status": "affected" } ] } ], "descriptions": [ { "lang": "en", "value": "A vulnerability has been found in Tenda i22 1.0.0.3(4687) and classified as problematic. Affected by this vulnerability is the function websReadEvent of the file /goform/GetIPTV?fgHPOST/goform/SysToo. The manipulation of the argument Content-Length leads to null pointer dereference. The attack can be launched remotely. The exploit has been disclosed to the public and may be used." }, { "lang": "de", "value": "In Tenda i22 1.0.0.3(4687) wurde eine Schwachstelle gefunden. Sie wurde als problematisch eingestuft. Hierbei betrifft es die Funktion websReadEvent der Datei /goform/GetIPTV?fgHPOST/goform/SysToo. Durch Beeinflussen des Arguments Content-Length mit unbekannten Daten kann eine null pointer dereference-Schwachstelle ausgenutzt werden. Umgesetzt werden kann der Angriff über das Netzwerk. Der Exploit steht zur öffentlichen Verfügung." } ], "metrics": [ { "cvssV4_0": { "version": "4.0", "baseScore": 7.1, "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:N/VI:N/VA:H/SC:N/SI:N/SA:N", "baseSeverity": "HIGH" } }, { "cvssV3_1": { "version": "3.1", "baseScore": 6.5, "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H", "baseSeverity": "MEDIUM" } }, { "cvssV3_0": { "version": "3.0", "baseScore": 6.5, "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H", "baseSeverity": "MEDIUM" } }, { "cvssV2_0": { "version": "2.0", "baseScore": 6.8, "vectorString": "AV:N/AC:L/Au:S/C:N/I:N/A:C" } } ], "timeline": [ { "time": "2024-11-03T00:00:00.000Z", "lang": "en", "value": "Advisory disclosed" }, { "time": "2024-11-03T01:00:00.000Z", "lang": "en", "value": "VulDB entry created" }, { "time": "2024-11-03T07:40:20.000Z", "lang": "en", "value": "VulDB entry last update" } ], "credits": [ { "lang": "en", "value": "xiaobor123 (VulDB User)", "type": "reporter" } ], "references": [ { "url": "https://vuldb.com/?id.282919", "name": "VDB-282919 | Tenda i22 SysToo websReadEvent null pointer dereference", "tags": [ "vdb-entry", "technical-description" ] }, { "url": "https://vuldb.com/?ctiid.282919", "name": "VDB-282919 | CTI Indicators (IOB, IOC, IOA)", "tags": [ "signature", "permissions-required" ] }, { "url": "https://vuldb.com/?submit.435407", "name": "Submit #435407 | Tenda i22 V1.0.0.3(4687) NULL Pointer Dereference", "tags": [ "third-party-advisory" ] }, { "url": "https://github.com/xiaobor123/tenda-vul-i22", "tags": [ "exploit" ] }, { "url": "https://www.tenda.com.cn/", "tags": [ "product" ] } ] }, "adp": [ { "affected": [ { "vendor": "tenda", "product": "i22", "cpes": [ "cpe:2.3:h:tenda:i22:-:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "versions": [ { "version": "1.0.0.3(4687)", "status": "affected" } ] } ], "metrics": [ { "other": { "type": "ssvc", "content": { "timestamp": "2024-11-05T14:54:25.326328Z", "id": "CVE-2024-10750", "options": [ { "Exploitation": "poc" }, { "Automatable": "no" }, { "Technical Impact": "partial" } ], "role": "CISA Coordinator", "version": "2.0.3" } } } ], "title": "CISA ADP Vulnrichment", "providerMetadata": { "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "shortName": "CISA-ADP", "dateUpdated": "2024-11-05T14:55:33.301Z" } } ] } }