{ "dataType": "CVE_RECORD", "dataVersion": "5.1", "cveMetadata": { "cveId": "CVE-2024-10944", "assignerOrgId": "b73dd486-f505-4403-b634-40b078b177f0", "state": "PUBLISHED", "assignerShortName": "Rockwell", "dateReserved": "2024-11-06T20:19:55.217Z", "datePublished": "2024-11-12T17:03:26.983Z", "dateUpdated": "2024-11-13T17:39:55.232Z" }, "containers": { "cna": { "affected": [ { "defaultStatus": "unaffected", "product": "FactoryTalk Updater", "vendor": "Rockwell Automation", "versions": [ { "status": "affected", "version": "<4.20.00" } ] } ], "datePublic": "2024-11-12T14:00:00.000Z", "descriptions": [ { "lang": "en", "supportingMedia": [ { "base64": false, "type": "text/html", "value": "
A Remote\nCode Execution vulnerability exists in the affected product. The vulnerability requires\na high level of permissions and exists due to improper input validation resulting\nin the possibility of a malicious Updated Agent being deployed.
" } ], "value": "A Remote\nCode Execution vulnerability exists in the affected product. The vulnerability requires\na high level of permissions and exists due to improper input validation resulting\nin the possibility of a malicious Updated Agent being deployed." } ], "impacts": [ { "capecId": "CAPEC-253", "descriptions": [ { "lang": "en", "value": "CAPEC-253 Remote Code Inclusion" } ] } ], "metrics": [ { "cvssV4_0": { "Automatable": "NOT_DEFINED", "Recovery": "NOT_DEFINED", "Safety": "NOT_DEFINED", "attackComplexity": "LOW", "attackRequirements": "PRESENT", "attackVector": "NETWORK", "baseScore": 7.1, "baseSeverity": "HIGH", "privilegesRequired": "HIGH", "providerUrgency": "NOT_DEFINED", "subAvailabilityImpact": "LOW", "subConfidentialityImpact": "LOW", "subIntegrityImpact": "LOW", "userInteraction": "ACTIVE", "valueDensity": "NOT_DEFINED", "vectorString": "CVSS:4.0/AV:N/AC:L/AT:P/PR:H/UI:A/VC:H/VI:H/VA:H/SC:L/SI:L/SA:L", "version": "4.0", "vulnAvailabilityImpact": "HIGH", "vulnConfidentialityImpact": "HIGH", "vulnIntegrityImpact": "HIGH", "vulnerabilityResponseEffort": "NOT_DEFINED" }, "format": "CVSS", "scenarios": [ { "lang": "en", "value": "GENERAL" } ] }, { "cvssV3_1": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 8.4, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "HIGH", "scope": "CHANGED", "userInteraction": "REQUIRED", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:R/S:C/C:H/I:H/A:H", "version": "3.1" }, "format": "CVSS", "scenarios": [ { "lang": "en", "value": "GENERAL" } ] } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-20", "description": "CWE-20 Improper Input Validation", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "orgId": "b73dd486-f505-4403-b634-40b078b177f0", "shortName": "Rockwell", "dateUpdated": "2024-11-12T17:03:26.983Z" }, "references": [ { "url": "https://www.rockwellautomation.com/en-us/trust-center/security-advisories/advisory.SD1710.html" } ], "solutions": [ { "lang": "en", "supportingMedia": [ { "base64": false, "type": "text/html", "value": "Upgrade to V4.20.00\n\n