{ "dataType": "CVE_RECORD", "dataVersion": "5.1", "cveMetadata": { "cveId": "CVE-2024-12297", "assignerOrgId": "2e0a0ee2-d866-482a-9f5e-ac03d156dbaa", "state": "PUBLISHED", "assignerShortName": "Moxa", "dateReserved": "2024-12-06T04:02:40.742Z", "datePublished": "2025-01-15T10:00:46.524Z", "dateUpdated": "2025-03-06T08:27:52.297Z" }, "containers": { "cna": { "affected": [ { "defaultStatus": "unaffected", "product": "EDS-508A Series", "vendor": "Moxa", "versions": [ { "lessThanOrEqual": "3.11", "status": "affected", "version": "1.0", "versionType": "custom" } ] }, { "defaultStatus": "unaffected", "product": "PT-508 Series", "vendor": "Moxa", "versions": [ { "lessThanOrEqual": "3.8", "status": "affected", "version": "1.0", "versionType": "custom" } ] }, { "defaultStatus": "unaffected", "product": "PT-510 Series", "vendor": "Moxa", "versions": [ { "lessThanOrEqual": "3.8", "status": "affected", "version": "1.0", "versionType": "custom" } ] }, { "defaultStatus": "unaffected", "product": "PT-7528 Series", "vendor": "Moxa", "versions": [ { "lessThanOrEqual": "5.0", "status": "affected", "version": "1.0", "versionType": "custom" } ] }, { "defaultStatus": "unaffected", "product": "PT-7728 Series", "vendor": "Moxa", "versions": [ { "lessThanOrEqual": "3.9", "status": "affected", "version": "1.0", "versionType": "custom" } ] }, { "defaultStatus": "unaffected", "product": "PT-7828 Series", "vendor": "Moxa", "versions": [ { "lessThanOrEqual": "4.0", "status": "affected", "version": "1.0", "versionType": "custom" } ] }, { "defaultStatus": "unaffected", "product": "PT-G503 Series", "vendor": "Moxa", "versions": [ { "lessThanOrEqual": "5.3", "status": "affected", "version": "1.0", "versionType": "custom" } ] }, { "defaultStatus": "unaffected", "product": "PT-G510 Series", "vendor": "Moxa", "versions": [ { "lessThanOrEqual": "6.5", "status": "affected", "version": "1.0", "versionType": "custom" } ] }, { "defaultStatus": "unaffected", "product": "PT-G7728 Series", "vendor": "Moxa", "versions": [ { "lessThanOrEqual": "6.5", "status": "affected", "version": "1.0", "versionType": "custom" } ] }, { "defaultStatus": "unaffected", "product": "PT-G7828 Series", "vendor": "Moxa", "versions": [ { "lessThanOrEqual": "6.5", "status": "affected", "version": "1.0", "versionType": "custom" } ] } ], "credits": [ { "lang": "en", "type": "finder", "value": "Artem Turyshev from Rosatom Automated Control Systems Joint-Stock Company" } ], "descriptions": [ { "lang": "en", "supportingMedia": [ { "base64": false, "type": "text/html", "value": "Moxa’s Ethernet switch is vulnerable to an authentication bypass because of flaws in its authorization mechanism. Although both client-side and back-end server verification are involved in the process, attackers can exploit weaknesses in its implementation. These vulnerabilities may enable brute-force attacks to guess valid credentials or MD5 collision attacks to forge authentication hashes, potentially compromising the security of the device.
" } ], "value": "Moxa’s Ethernet switch is vulnerable to an authentication bypass because of flaws in its authorization mechanism. Although both client-side and back-end server verification are involved in the process, attackers can exploit weaknesses in its implementation. These vulnerabilities may enable brute-force attacks to guess valid credentials or MD5 collision attacks to forge authentication hashes, potentially compromising the security of the device." } ], "impacts": [ { "capecId": "CAPEC-49", "descriptions": [ { "lang": "en", "value": "CAPEC-49: Password Brute Forcing" } ] } ], "metrics": [ { "cvssV4_0": { "Automatable": "NOT_DEFINED", "Recovery": "NOT_DEFINED", "Safety": "NOT_DEFINED", "attackComplexity": "LOW", "attackRequirements": "PRESENT", "attackVector": "NETWORK", "baseScore": 9.2, "baseSeverity": "CRITICAL", "privilegesRequired": "NONE", "providerUrgency": "NOT_DEFINED", "subAvailabilityImpact": "LOW", "subConfidentialityImpact": "LOW", "subIntegrityImpact": "LOW", "userInteraction": "NONE", "valueDensity": "NOT_DEFINED", "vectorString": "CVSS:4.0/AV:N/AC:L/AT:P/PR:N/UI:N/VC:H/VI:H/VA:H/SC:L/SI:L/SA:L", "version": "4.0", "vulnAvailabilityImpact": "HIGH", "vulnConfidentialityImpact": "HIGH", "vulnIntegrityImpact": "HIGH", "vulnerabilityResponseEffort": "NOT_DEFINED" }, "format": "CVSS", "scenarios": [ { "lang": "en", "value": "GENERAL" } ] } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-656", "description": "CWE-656: Reliance on Security Through Obscurity", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "orgId": "2e0a0ee2-d866-482a-9f5e-ac03d156dbaa", "shortName": "Moxa", "dateUpdated": "2025-03-06T08:27:52.297Z" }, "references": [ { "tags": [ "vendor-advisory" ], "url": "https://www.moxa.com/en/support/product-support/security-advisory/mpsa-241407-cve-2024-12297-frontend-authorization-logic-disclosure-vulnerability-in-eds-508a-series" }, { "tags": [ "vendor-advisory" ], "url": "https://www.moxa.com/en/support/product-support/security-advisory/mpsa-241408-cve-2024-12297-frontend-authorization-logic-disclosure-vulnerability-identified-in-pt-switches" } ], "solutions": [ { "lang": "en", "supportingMedia": [ { "base64": false, "type": "text/html", "value": "

Moxa has released appropriate solutions to address vulnerability. The solutions for the affected products are listed below.

" } ], "value": "Moxa has released appropriate solutions to address vulnerability. The solutions for the affected products are listed below.\n\n * EDS-508A Series: Please contact Moxa Technical Support for the security patch\n\n\n * PT Series: Please contact Moxa Technical Support for the security patch" } ], "source": { "discovery": "EXTERNAL" }, "title": "Frontend Authorization Logic Disclosure Vulnerability", "workarounds": [ { "lang": "en", "supportingMedia": [ { "base64": false, "type": "text/html", "value": "
" } ], "value": "* Minimize network exposure to ensure the device is not accessible from the Internet.\n * Limit SSH access to trusted IP addresses and networks using firewall rules or TCP wrappers. \n * Implement IDS or Intrusion Prevention System (IPS) to detect and prevent exploitation attempts. These systems can provide an additional layer of defense by monitoring network traffic for signs of attacks." } ], "x_generator": { "engine": "Vulnogram 0.2.0" } }, "adp": [ { "metrics": [ { "other": { "type": "ssvc", "content": { "timestamp": "2025-01-15T14:49:11.063174Z", "id": "CVE-2024-12297", "options": [ { "Exploitation": "none" }, { "Automatable": "no" }, { "Technical Impact": "total" } ], "role": "CISA Coordinator", "version": "2.0.3" } } } ], "title": "CISA ADP Vulnrichment", "providerMetadata": { "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "shortName": "CISA-ADP", "dateUpdated": "2025-01-15T14:49:22.117Z" } } ] } }