{ "dataType": "CVE_RECORD", "dataVersion": "5.1", "cveMetadata": { "cveId": "CVE-2024-13502", "assignerOrgId": "455daabc-a392-441d-aa46-37d35189897c", "state": "PUBLISHED", "assignerShortName": "NCSC.ch", "dateReserved": "2025-01-17T10:25:40.676Z", "datePublished": "2025-01-17T14:01:03.084Z", "dateUpdated": "2025-01-17T14:49:20.740Z" }, "containers": { "cna": { "affected": [ { "defaultStatus": "affected", "platforms": [ "Linux", "PowerPC", "ARM" ], "product": "NTC2218, NTC2250, NTC2299", "vendor": "Newtec/iDirect", "versions": [ { "lessThanOrEqual": "2.2.6.19", "status": "affected", "version": "1.0.1.1", "versionType": "semver" } ] } ], "credits": [ { "lang": "en", "type": "finder", "value": "James Pavur" }, { "lang": "en", "type": "reporter", "value": "Johannes Willbold, johannes.willbold@rub.de" }, { "lang": "en", "type": "coordinator", "value": "Martin Strohmeier, martin.strohmeier@armasuisse.ch" } ], "descriptions": [ { "lang": "en", "supportingMedia": [ { "base64": false, "type": "text/html", "value": "Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection') vulnerability in Newtec/iDirect NTC2218, NTC2250, NTC2299 on Linux, PowerPC, ARM allows Local Code Inclusion.
This issue affects NTC2218, NTC2250, NTC2299: from 1.0.1.1 through 2.2.6.19.
The `commit_multicast` page used to configure multicasts in the modem's web administration interface uses improperly parses incoming data from the request before passing it to an `eval` statement in a bash script. This allows attackers to inject arbitrary shell commands.