{ "dataType": "CVE_RECORD", "dataVersion": "5.1", "cveMetadata": { "cveId": "CVE-2024-43655", "assignerOrgId": "b87402ff-ae37-4194-9dae-31abdbd6f217", "state": "PUBLISHED", "assignerShortName": "DIVD", "dateReserved": "2024-08-14T09:27:41.768Z", "datePublished": "2025-01-09T07:56:45.279Z", "dateUpdated": "2025-03-11T13:07:19.985Z" }, "containers": { "cna": { "affected": [ { "defaultStatus": "unaffected", "product": "Iocharger firmware for AC models", "vendor": "Iocharger", "versions": [ { "lessThan": "24120701", "status": "affected", "version": "0", "versionType": "custom" } ] } ], "credits": [ { "lang": "en", "type": "finder", "value": "Wilco van Beijnum" }, { "lang": "en", "type": "analyst", "value": "Harm van den Brink (DIVD)" }, { "lang": "en", "type": "analyst", "value": "Frank Breedijk (DIVD)" } ], "datePublic": "2025-01-09T00:00:00.000Z", "descriptions": [ { "lang": "en", "supportingMedia": [ { "base64": false, "type": "text/html", "value": "Improper Neutralization of Special Elements used in a Command ('Command Injection') vulnerability allows OS Command Injection as root

This issue affects Iocharger firmware for AC model chargers before version 24120701.

Likelihood: Moderate – The attacker will first need to find the name of the script, and needs a (low privilege) account to gain access to the script, or convince a user with such access to execute a request to it.

Impact: Critical – The attacker has full control over the charging station as the root user, and can arbitrarily add, modify and deletefiles and services.

CVSS clarification: Any network interface serving the web ui is vulnerable (AV:N) and there are not additional security measures to circumvent (AC:L), nor does the attack require and existing preconditions (AT:N). The attack is authenticated, but the level of authentication does not matter (PR:L), nor is any user interaction required (UI:N). The attack leads to a full compromised (VC:H/VI:H/VA:H), and compromised devices can be used to pivot into networks that should potentially not be accessible (SC:L/SI:L/SA:H). Becuase this is an EV charger handing significant power, there is a potential safety impact (S:P). This attack can be automated (AU:Y).
" } ], "value": "Improper Neutralization of Special Elements used in a Command ('Command Injection') vulnerability allows OS Command Injection as root\n\nThis issue affects Iocharger firmware for AC model chargers before version 24120701.\n\nLikelihood: Moderate – The attacker will first need to find the name of the script, and needs a (low privilege) account to gain access to the script, or convince a user with such access to execute a request to it.\n\nImpact: Critical – The attacker has full control over the charging station as the root user, and can arbitrarily add, modify and deletefiles and services.\n\nCVSS clarification: Any network interface serving the web ui is vulnerable (AV:N) and there are not additional security measures to circumvent (AC:L), nor does the attack require and existing preconditions (AT:N). The attack is authenticated, but the level of authentication does not matter (PR:L), nor is any user interaction required (UI:N). The attack leads to a full compromised (VC:H/VI:H/VA:H), and compromised devices can be used to pivot into networks that should potentially not be accessible (SC:L/SI:L/SA:H). Becuase this is an EV charger handing significant power, there is a potential safety impact (S:P). This attack can be automated (AU:Y)." } ], "impacts": [ { "capecId": "CAPEC-88", "descriptions": [ { "lang": "en", "value": "CAPEC-88 OS Command Injection" } ] } ], "metrics": [ { "cvssV4_0": { "Automatable": "YES", "Recovery": "NOT_DEFINED", "Safety": "PRESENT", "attackComplexity": "LOW", "attackRequirements": "NONE", "attackVector": "NETWORK", "baseScore": 9.3, "baseSeverity": "CRITICAL", "privilegesRequired": "LOW", "providerUrgency": "NOT_DEFINED", "subAvailabilityImpact": "HIGH", "subConfidentialityImpact": "LOW", "subIntegrityImpact": "LOW", "userInteraction": "NONE", "valueDensity": "NOT_DEFINED", "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:L/SI:L/SA:H/S:P/AU:Y", "version": "4.0", "vulnAvailabilityImpact": "HIGH", "vulnConfidentialityImpact": "HIGH", "vulnIntegrityImpact": "HIGH", "vulnerabilityResponseEffort": "NOT_DEFINED" }, "format": "CVSS", "scenarios": [ { "lang": "en", "value": "GENERAL" } ] } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-78", "description": "CWE-78 Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')", "lang": "en", "type": "CWE" } ] }, { "descriptions": [ { "cweId": "CWE-250", "description": "CWE-250: Execution with Unnecessary Privileges", "lang": "en", "type": "CWE" } ] }, { "descriptions": [ { "description": "OWASP-A03: Injection", "lang": "en" } ] } ], "providerMetadata": { "orgId": "b87402ff-ae37-4194-9dae-31abdbd6f217", "shortName": "DIVD", "dateUpdated": "2025-03-11T13:07:19.985Z" }, "references": [ { "tags": [ "third-party-advisory" ], "url": "https://csirt.divd.nl/DIVD-2024-00035/" }, { "tags": [ "third-party-advisory" ], "url": "https://csirt.divd.nl/CVE-2024-43655/" }, { "tags": [ "product" ], "url": "https://iocharger.com" } ], "source": { "advisory": "DIVD-2024-00035", "discovery": "EXTERNAL" }, "title": "Any authenticated users can execute OS commands as root using the .sh CGI script.", "x_generator": { "engine": "Vulnogram 0.2.0" } }, "adp": [ { "metrics": [ { "other": { "type": "ssvc", "content": { "timestamp": "2025-01-09T15:11:43.639526Z", "id": "CVE-2024-43655", "options": [ { "Exploitation": "none" }, { "Automatable": "no" }, { "Technical Impact": "total" } ], "role": "CISA Coordinator", "version": "2.0.3" } } } ], "title": "CISA ADP Vulnrichment", "providerMetadata": { "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "shortName": "CISA-ADP", "dateUpdated": "2025-01-09T15:12:19.472Z" } } ] } }