{ "dataType": "CVE_RECORD", "dataVersion": "5.1", "cveMetadata": { "cveId": "CVE-2024-4641", "assignerOrgId": "2e0a0ee2-d866-482a-9f5e-ac03d156dbaa", "state": "PUBLISHED", "assignerShortName": "Moxa", "dateReserved": "2024-05-08T00:44:45.219Z", "datePublished": "2024-06-25T09:23:30.502Z", "dateUpdated": "2024-08-01T20:47:41.226Z" }, "containers": { "cna": { "affected": [ { "defaultStatus": "unaffected", "product": "OnCell G3150A-LTE Series", "vendor": "Moxa", "versions": [ { "lessThanOrEqual": "1.7.7", "status": "affected", "version": "1.0", "versionType": "custom" } ] } ], "credits": [ { "lang": "en", "type": "finder", "value": "Nikita Abramov from Positive Technologies" } ], "descriptions": [ { "lang": "en", "supportingMedia": [ { "base64": false, "type": "text/html", "value": "OnCell G3470A-LTE Series firmware versions v1.7.7 and prior have been identified as vulnerable due to accepting a format string from an external source as an argument. An attacker could modify an externally controlled format string to cause a memory leak and denial of service." } ], "value": "OnCell G3470A-LTE Series firmware versions v1.7.7 and prior have been identified as vulnerable due to accepting a format string from an external source as an argument. An attacker could modify an externally controlled format string to cause a memory leak and denial of service." } ], "impacts": [ { "capecId": "CAPEC-135", "descriptions": [ { "lang": "en", "value": "CAPEC-135: Format String Injection" } ] } ], "metrics": [ { "cvssV3_1": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "LOW", "baseScore": 6.3, "baseSeverity": "MEDIUM", "confidentialityImpact": "LOW", "integrityImpact": "LOW", "privilegesRequired": "LOW", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:L/A:L", "version": "3.1" }, "format": "CVSS", "scenarios": [ { "lang": "en", "value": "GENERAL" } ] } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-134", "description": "CWE-134: Use of Externally-Controlled Format String", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "orgId": "2e0a0ee2-d866-482a-9f5e-ac03d156dbaa", "shortName": "Moxa", "dateUpdated": "2024-06-25T09:23:30.502Z" }, "references": [ { "tags": [ "vendor-advisory" ], "url": "https://www.moxa.com/en/support/product-support/security-advisory/mpsa-242550-oncell-g3470a-lte-series-multiple-web-application-vulnerabilities" } ], "solutions": [ { "lang": "en", "supportingMedia": [ { "base64": false, "type": "text/html", "value": "
Moxa has developed appropriate solutions to address the vulnerabilities. The solutions for affected products are shown below.
Moxa recommends users to implement the following mitigations if necessary: