"dataType": "CVE_RECORD",
"dataVersion": "5.1",
"cveMetadata": {
"cveId": "CVE-2024-6071",
"assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
"state": "PUBLISHED",
"assignerShortName": "icscert",
"dateReserved": "2024-06-17T15:17:28.397Z",
"datePublished": "2024-06-27T23:05:03.183Z",
"dateUpdated": "2024-08-01T21:25:03.240Z"
},
"containers": {
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "Creo Elements/Direct License",
"vendor": "PTC",
"versions": [
{
"lessThanOrEqual": "20.7.0.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "finder",
"value": "Thomas Riedmaier of Siemens Energy reported this vulnerability to PTC."
}
],
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "\n\nPTC Creo Elements/Direct License Server exposes a web interface which can be used by unauthenticated remote attackers to execute arbitrary OS commands on the server.
"
}
],
"value": "PTC Creo Elements/Direct License Server exposes a web interface which can be used by unauthenticated remote attackers to execute arbitrary OS commands on the server."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 10,
"baseSeverity": "CRITICAL",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "CHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
},
{
"cvssV4_0": {
"Automatable": "NOT_DEFINED",
"Recovery": "NOT_DEFINED",
"Safety": "NOT_DEFINED",
"attackComplexity": "LOW",
"attackRequirements": "NONE",
"attackVector": "NETWORK",
"baseScore": 10,
"baseSeverity": "CRITICAL",
"privilegesRequired": "NONE",
"providerUrgency": "NOT_DEFINED",
"subAvailabilityImpact": "HIGH",
"subConfidentialityImpact": "HIGH",
"subIntegrityImpact": "HIGH",
"userInteraction": "NONE",
"valueDensity": "NOT_DEFINED",
"vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:H/SI:H/SA:H",
"version": "4.0",
"vulnAvailabilityImpact": "HIGH",
"vulnConfidentialityImpact": "HIGH",
"vulnIntegrityImpact": "HIGH",
"vulnerabilityResponseEffort": "NOT_DEFINED"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-862",
"description": "CWE-862 Missing Authorization",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
"shortName": "icscert",
"dateUpdated": "2024-06-27T23:05:03.183Z"
},
"references": [
{
"url": "https://www.cisa.gov/news-events/ics-advisories/icsa-24-177-02"
},
{
"url": "https://www.ptc.com/en/support/article/CS417607"
}
],
"solutions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "\n\n
PTC recommends that users upgrade to Creo Elements/Direct License Server 20.7.0.1 or higher version:
If additional questions remain, please contact PTC Technical Support.
For more information, see PTC's CS article.
\n\n" } ], "value": "PTC recommends that users upgrade to Creo Elements/Direct License Server 20.7.0.1 or higher version:\n\n * Creo Elements/Direct Drafting https://support.ptc.com/appserver/auth/it/esd/product.jsp \n * Creo Elements/Direct Model/Drawing Mgr https://support.ptc.com/appserver/auth/it/esd/product.jsp \n * Creo Elements/Direct Modeling https://support.ptc.com/appserver/auth/it/esd/product.jsp \n * Creo Elements/Direct WorkManager https://support.ptc.com/appserver/auth/it/esd/product.jsp \n\n\nIf additional questions remain, please contact PTC Technical Support. https://support.ptc.com/apps/case_logger_viewer/cs/auth/ssl/log \n\nFor more information, see PTC's CS article https://www.ptc.com/en/support/article/CS417607 ." } ], "source": { "advisory": "ICSA-24-177-02", "discovery": "EXTERNAL" }, "title": "PTC Creo Elements/Direct License Server Missing Authorization", "x_generator": { "engine": "Vulnogram 0.2.0" } }, "adp": [ { "affected": [ { "vendor": "creo", "product": "creo_elements\\/direct_license", "cpes": [ "cpe:2.3:a:creo:creo_elements\\/direct_license:0:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "versions": [ { "version": "0", "status": "affected", "lessThanOrEqual": "20.7.0.0", "versionType": "custom" } ] } ], "metrics": [ { "other": { "type": "ssvc", "content": { "timestamp": "2024-06-28T15:22:36.234542Z", "id": "CVE-2024-6071", "options": [ { "Exploitation": "none" }, { "Automatable": "no" }, { "Technical Impact": "total" } ], "role": "CISA Coordinator", "version": "2.0.3" } } } ], "title": "CISA ADP Vulnrichment", "providerMetadata": { "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "shortName": "CISA-ADP", "dateUpdated": "2024-06-28T15:26:22.615Z" } }, { "providerMetadata": { "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE", "dateUpdated": "2024-08-01T21:25:03.240Z" }, "title": "CVE Program Container", "references": [ { "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-24-177-02", "tags": [ "x_transferred" ] }, { "url": "https://www.ptc.com/en/support/article/CS417607", "tags": [ "x_transferred" ] } ] } ] } }