{ "dataType": "CVE_RECORD", "dataVersion": "5.1", "cveMetadata": { "cveId": "CVE-2024-7988", "assignerOrgId": "b73dd486-f505-4403-b634-40b078b177f0", "state": "PUBLISHED", "assignerShortName": "Rockwell", "dateReserved": "2024-08-19T20:06:27.545Z", "datePublished": "2024-08-26T14:47:07.612Z", "dateUpdated": "2024-08-26T17:46:47.107Z" }, "containers": { "cna": { "affected": [ { "defaultStatus": "unaffected", "product": "ThinManager® ThinServer™", "vendor": "Rockwell Automation", "versions": [ { "status": "affected", "version": "11.1.0-11.1.7 11.2.0-11.2.8 12.0.0-12.0.6 12.1.0-12.1.7 13.0.0-13.0.4 13.1.0-13.1.2 13.2.0-13.2.1" } ] } ], "datePublic": "2024-08-26T13:00:00.000Z", "descriptions": [ { "lang": "en", "supportingMedia": [ { "base64": false, "type": "text/html", "value": "A remote code execution vulnerability exists in the Rockwell Automation ThinManager® ThinServer™ that allows a threat actor to execute arbitrary code with System privileges. This vulnerability exists due to the lack of proper data input validation, which allows files to be overwritten." } ], "value": "A remote code execution vulnerability exists in the Rockwell Automation ThinManager® ThinServer™ that allows a threat actor to execute arbitrary code with System privileges. This vulnerability exists due to the lack of proper data input validation, which allows files to be overwritten." } ], "impacts": [ { "capecId": "CAPEC-153", "descriptions": [ { "lang": "en", "value": "CAPEC-153 Input Data Manipulation" } ] } ], "metrics": [ { "cvssV4_0": { "Automatable": "NOT_DEFINED", "Recovery": "NOT_DEFINED", "Safety": "NOT_DEFINED", "attackComplexity": "LOW", "attackRequirements": "NONE", "attackVector": "NETWORK", "baseScore": 9.3, "baseSeverity": "CRITICAL", "privilegesRequired": "NONE", "providerUrgency": "NOT_DEFINED", "subAvailabilityImpact": "NONE", "subConfidentialityImpact": "NONE", "subIntegrityImpact": "NONE", "userInteraction": "NONE", "valueDensity": "NOT_DEFINED", "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N", "version": "4.0", "vulnAvailabilityImpact": "HIGH", "vulnConfidentialityImpact": "HIGH", "vulnIntegrityImpact": "HIGH", "vulnerabilityResponseEffort": "NOT_DEFINED" }, "format": "CVSS", "scenarios": [ { "lang": "en", "value": "GENERAL" } ] } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-20", "description": "CWE-20 Improper Input Validation", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "orgId": "b73dd486-f505-4403-b634-40b078b177f0", "shortName": "Rockwell", "dateUpdated": "2024-08-26T14:47:07.612Z" }, "references": [ { "url": "https://www.rockwellautomation.com/en-us/trust-center/security-advisories/advisory.SD1692.html" } ], "solutions": [ { "lang": "en", "supportingMedia": [ { "base64": false, "type": "text/html", "value": "
Affected Product | First Known in software version | Corrected in software version |
ThinManager® ThinServer™ | 11.1.0-11.1.7 | 11.1.8 11.2.9 12.0.7 12.1.8 13.0.5 13.1.3 13.2.2 |
Mitigations and Workarounds
Customers using the affected software are encouraged to implement our suggested security best practices to minimize the risk of vulnerability.
\n\n