{ "dataType": "CVE_RECORD", "dataVersion": "5.1", "cveMetadata": { "cveId": "CVE-2025-0498", "assignerOrgId": "b73dd486-f505-4403-b634-40b078b177f0", "state": "PUBLISHED", "assignerShortName": "Rockwell", "dateReserved": "2025-01-15T15:46:08.098Z", "datePublished": "2025-01-30T17:36:12.542Z", "dateUpdated": "2025-02-12T19:51:11.392Z" }, "containers": { "cna": { "affected": [ { "defaultStatus": "unaffected", "product": "FactoryTalk® AssetCentre", "vendor": "Rockwell Automation", "versions": [ { "status": "affected", "version": "All prior to V15.00.001" } ] } ], "datePublic": "2025-01-30T17:32:00.000Z", "descriptions": [ { "lang": "en", "supportingMedia": [ { "base64": false, "type": "text/html", "value": "A data exposure vulnerability exists in all versions prior to V15.00.001 of Rockwell Automation FactoryTalk® AssetCentre. The vulnerability exists due to insecure storage of FactoryTalk® Security user tokens, which could allow a threat actor to steal a token and, impersonate another user.\n\n
" } ], "value": "A data exposure vulnerability exists in all versions prior to V15.00.001 of Rockwell Automation FactoryTalk® AssetCentre. The vulnerability exists due to insecure storage of FactoryTalk® Security user tokens, which could allow a threat actor to steal a token and, impersonate another user." } ], "metrics": [ { "cvssV4_0": { "Automatable": "NOT_DEFINED", "Recovery": "NOT_DEFINED", "Safety": "NOT_DEFINED", "attackComplexity": "LOW", "attackRequirements": "NONE", "attackVector": "LOCAL", "baseScore": 7, "baseSeverity": "HIGH", "privilegesRequired": "LOW", "providerUrgency": "NOT_DEFINED", "subAvailabilityImpact": "NONE", "subConfidentialityImpact": "NONE", "subIntegrityImpact": "NONE", "userInteraction": "PASSIVE", "valueDensity": "NOT_DEFINED", "vectorString": "CVSS:4.0/AV:L/AC:L/AT:N/PR:L/UI:P/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N", "version": "4.0", "vulnAvailabilityImpact": "HIGH", "vulnConfidentialityImpact": "HIGH", "vulnIntegrityImpact": "HIGH", "vulnerabilityResponseEffort": "NOT_DEFINED" }, "format": "CVSS", "scenarios": [ { "lang": "en", "value": "GENERAL" } ] } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-522", "description": "CWE-522 Insufficiently Protected Credentials", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "orgId": "b73dd486-f505-4403-b634-40b078b177f0", "shortName": "Rockwell", "dateUpdated": "2025-01-30T17:37:30.249Z" }, "references": [ { "url": "https://www.rockwellautomation.com/en-us/trust-center/security-advisories/advisory.SD1721.html" } ], "solutions": [ { "lang": "en", "supportingMedia": [ { "base64": false, "type": "text/html", "value": "Corrected in:

\n\n

V11, V12, and V13 (patch available)

V15.00.01 and later

\n\n
" } ], "value": "Corrected in:\n\n\n\nV11, V12, and V13 (patch available)\n\nV15.00.01 and later" } ], "source": { "advisory": "SD1721", "discovery": "INTERNAL" }, "title": "Rockwell Automation FactoryTalk® AssetCentre Data Exposure Vulnerability", "x_generator": { "engine": "Vulnogram 0.2.0" } }, "adp": [ { "metrics": [ { "other": { "type": "ssvc", "content": { "id": "CVE-2025-0498", "role": "CISA Coordinator", "options": [ { "Exploitation": "none" }, { "Automatable": "no" }, { "Technical Impact": "total" } ], "version": "2.0.3", "timestamp": "2025-01-30T19:52:41.177477Z" } } } ], "title": "CISA ADP Vulnrichment", "providerMetadata": { "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "shortName": "CISA-ADP", "dateUpdated": "2025-02-12T19:51:11.392Z" } } ] } }