{ "dataType": "CVE_RECORD", "dataVersion": "5.1", "cveMetadata": { "cveId": "CVE-2025-0960", "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6", "state": "PUBLISHED", "assignerShortName": "icscert", "dateReserved": "2025-01-31T22:04:58.932Z", "datePublished": "2025-02-04T19:34:25.961Z", "dateUpdated": "2025-02-04T19:50:52.268Z" }, "containers": { "cna": { "affected": [ { "defaultStatus": "unaffected", "product": "C-more EA9 HMI EA9-T6CL", "vendor": "AutomationDirect", "versions": [ { "lessThanOrEqual": "v6.79", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unaffected", "product": "C-more EA9 HMI EA9-T7CL-R", "vendor": "AutomationDirect", "versions": [ { "lessThanOrEqual": "v6.79", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unaffected", "product": "C-more EA9 HMI EA9-T7CL", "vendor": "AutomationDirect", "versions": [ { "lessThanOrEqual": "v6.79", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unaffected", "product": "C-more EA9 HMI EA9-T8CL", "vendor": "AutomationDirect", "versions": [ { "lessThanOrEqual": "v6.79", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unaffected", "product": "C-more EA9 HMI EA9-T10CL", "vendor": "AutomationDirect", "versions": [ { "lessThanOrEqual": "v6.79", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unaffected", "product": "C-more EA9 HMI EA9-T10WCL", "vendor": "AutomationDirect", "versions": [ { "lessThanOrEqual": "v6.79", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unaffected", "product": "C-more EA9 HMI EA9-T12CL", "vendor": "AutomationDirect", "versions": [ { "lessThanOrEqual": "v6.79", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unaffected", "product": "C-more EA9 HMI EA9-T15CL-R", "vendor": "AutomationDirect", "versions": [ { "lessThanOrEqual": "v6.79", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unaffected", "product": "C-more EA9 HMI EA9-T15CL", "vendor": "AutomationDirect", "versions": [ { "lessThanOrEqual": "v6.79", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unaffected", "product": "C-more EA9 HMI EA9-RHMI", "vendor": "AutomationDirect", "versions": [ { "lessThanOrEqual": "v6.79", "status": "affected", "version": "0", "versionType": "custom" } ] } ], "credits": [ { "lang": "en", "type": "finder", "value": "Sharon Brizinov of Claroty Team82 reported this vulnerability to CISA." } ], "datePublic": "2025-02-04T16:00:00.000Z", "descriptions": [ { "lang": "en", "supportingMedia": [ { "base64": false, "type": "text/html", "value": "AutomationDirect C-more EA9 HMI contains a function with bounds checks that can be skipped, which could result in an attacker abusing the function to cause a denial-of-service condition or achieving remote code execution on the affected device." } ], "value": "AutomationDirect C-more EA9 HMI contains a function with bounds checks that can be skipped, which could result in an attacker abusing the function to cause a denial-of-service condition or achieving remote code execution on the affected device." } ], "metrics": [ { "cvssV4_0": { "Automatable": "NOT_DEFINED", "Recovery": "NOT_DEFINED", "Safety": "NOT_DEFINED", "attackComplexity": "LOW", "attackRequirements": "NONE", "attackVector": "NETWORK", "baseScore": 9.3, "baseSeverity": "CRITICAL", "privilegesRequired": "NONE", "providerUrgency": "NOT_DEFINED", "subAvailabilityImpact": "NONE", "subConfidentialityImpact": "NONE", "subIntegrityImpact": "NONE", "userInteraction": "NONE", "valueDensity": "NOT_DEFINED", "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N", "version": "4.0", "vulnAvailabilityImpact": "HIGH", "vulnConfidentialityImpact": "HIGH", "vulnIntegrityImpact": "HIGH", "vulnerabilityResponseEffort": "NOT_DEFINED" }, "format": "CVSS", "scenarios": [ { "lang": "en", "value": "GENERAL" } ] }, { "cvssV3_1": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 9.8, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, "format": "CVSS", "scenarios": [ { "lang": "en", "value": "GENERAL" } ] } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-120", "description": "CWE-120 Buffer Copy without Checking Size of Input ('Classic Buffer Overflow')", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6", "shortName": "icscert", "dateUpdated": "2025-02-04T19:34:25.961Z" }, "references": [ { "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-25-035-08" }, { "url": "https://community.automationdirect.com/s/cybersecurity/security-advisories" } ], "solutions": [ { "lang": "en", "supportingMedia": [ { "base64": false, "type": "text/html", "value": "
AutomationDirect recommends that users update C-MORE EA9 HMI software and firmware to V6.80.
If an immediate update is not feasible, AutomationDirect recommends \nconsidering the following interim steps until the programming software \ncan be updated: