{ "dataType": "CVE_RECORD", "dataVersion": "5.1", "cveMetadata": { "cveId": "CVE-2025-24480", "assignerOrgId": "b73dd486-f505-4403-b634-40b078b177f0", "state": "PUBLISHED", "assignerShortName": "Rockwell", "dateReserved": "2025-01-21T21:21:03.342Z", "datePublished": "2025-01-28T19:01:41.484Z", "dateUpdated": "2025-02-05T18:49:55.832Z" }, "containers": { "cna": { "affected": [ { "defaultStatus": "unaffected", "product": "FactoryTalk® View Machine Edition", "vendor": "Rockwell Automation", "versions": [ { "status": "affected", "version": "A Remote Code Execution Vulnerability exists in the product and version listed above. The vulnerability is due to lack of input sanitation and could allow a remote attacker to run commands or code as a high privileged user." } ], "value": "A Remote Code Execution Vulnerability exists in the product and version listed above. The vulnerability is due to lack of input sanitation and could allow a remote attacker to run commands or code as a high privileged user." } ], "impacts": [ { "capecId": "CAPEC-88", "descriptions": [ { "lang": "en", "value": "CAPEC-88: OS Command Injection" } ] } ], "metrics": [ { "cvssV4_0": { "Automatable": "NOT_DEFINED", "Recovery": "NOT_DEFINED", "Safety": "NOT_DEFINED", "attackComplexity": "LOW", "attackRequirements": "NONE", "attackVector": "NETWORK", "baseScore": 9.3, "baseSeverity": "CRITICAL", "privilegesRequired": "NONE", "providerUrgency": "NOT_DEFINED", "subAvailabilityImpact": "NONE", "subConfidentialityImpact": "NONE", "subIntegrityImpact": "NONE", "userInteraction": "NONE", "valueDensity": "NOT_DEFINED", "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N", "version": "4.0", "vulnAvailabilityImpact": "HIGH", "vulnConfidentialityImpact": "HIGH", "vulnIntegrityImpact": "HIGH", "vulnerabilityResponseEffort": "NOT_DEFINED" }, "format": "CVSS", "scenarios": [ { "lang": "en", "value": "GENERAL" } ] } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-78", "description": "CWE-78 Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "orgId": "b73dd486-f505-4403-b634-40b078b177f0", "shortName": "Rockwell", "dateUpdated": "2025-02-05T18:49:55.832Z" }, "references": [ { "url": "https://www.rockwellautomation.com/en-us/trust-center/security-advisories/advisory.SD1719.html" } ], "solutions": [ { "lang": "en", "supportingMedia": [ { "base64": false, "type": "text/html", "value": "Upgrade to V15.00 or apply patch in AID 1152571\n\n
" } ], "value": "Upgrade to V15.00 or apply patch in AID 1152571" } ], "source": { "discovery": "INTERNAL" }, "title": "FactoryTalk® View Machine Editon - Remote Code Execution", "workarounds": [ { "lang": "en", "supportingMedia": [ { "base64": false, "type": "text/html", "value": "

Protect network access to the device & strictly constrain the parameters of invoked functions

\n\n
" } ], "value": "Protect network access to the device & strictly constrain the parameters of invoked functions" } ], "x_generator": { "engine": "Vulnogram 0.2.0" } }, "adp": [ { "metrics": [ { "other": { "type": "ssvc", "content": { "timestamp": "2025-01-28T19:20:28.530752Z", "id": "CVE-2025-24480", "options": [ { "Exploitation": "none" }, { "Automatable": "yes" }, { "Technical Impact": "partial" } ], "role": "CISA Coordinator", "version": "2.0.3" } } } ], "title": "CISA ADP Vulnrichment", "providerMetadata": { "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "shortName": "CISA-ADP", "dateUpdated": "2025-01-28T19:20:34.732Z" } } ] } }