{ "dataType": "CVE_RECORD", "dataVersion": "5.1", "cveMetadata": { "cveId": "CVE-2025-27261", "assignerOrgId": "85b1779b-6ecd-4f52-bcc5-73eac4659dcf", "state": "PUBLISHED", "assignerShortName": "ERIC", "dateReserved": "2025-02-21T08:58:20.367Z", "datePublished": "2025-09-25T13:47:06.233Z", "dateUpdated": "2025-09-30T12:12:39.842Z" }, "containers": { "cna": { "affected": [ { "defaultStatus": "affected", "product": "Indoor Connect 8855", "vendor": "Ericsson", "versions": [ { "changes": [ { "at": "2025.Q2", "status": "unaffected" } ], "lessThan": "2025.Q2", "status": "affected", "version": "0", "versionType": "Indoor Connect 8855" } ] } ], "credits": [ { "lang": "en", "type": "finder", "value": "Telstra" } ], "descriptions": [ { "lang": "en", "supportingMedia": [ { "base64": false, "type": "text/html", "value": "Ericsson Indoor Connect 8855 contains an SQL injection vulnerability which if exploited can result in unauthorized disclosure or modification of data." } ], "value": "Ericsson Indoor Connect 8855 contains an SQL injection vulnerability which if exploited can result in unauthorized disclosure or modification of data." } ], "metrics": [ { "cvssV4_0": { "Automatable": "NOT_DEFINED", "Recovery": "NOT_DEFINED", "Safety": "NOT_DEFINED", "attackComplexity": "LOW", "attackRequirements": "NONE", "attackVector": "NETWORK", "baseScore": 8.7, "baseSeverity": "HIGH", "privilegesRequired": "LOW", "providerUrgency": "NOT_DEFINED", "subAvailabilityImpact": "NONE", "subConfidentialityImpact": "NONE", "subIntegrityImpact": "NONE", "userInteraction": "NONE", "valueDensity": "NOT_DEFINED", "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N", "version": "4.0", "vulnAvailabilityImpact": "HIGH", "vulnConfidentialityImpact": "HIGH", "vulnIntegrityImpact": "HIGH", "vulnerabilityResponseEffort": "NOT_DEFINED" }, "format": "CVSS", "scenarios": [ { "lang": "en", "value": "GENERAL" } ] } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-89", "description": "CWE-89 Improper Neutralization of Special Elements used in an SQL Command ('SQL Injection')", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "orgId": "85b1779b-6ecd-4f52-bcc5-73eac4659dcf", "shortName": "ERIC", "dateUpdated": "2025-09-30T12:12:39.842Z" }, "references": [ { "url": "https://www.ericsson.com/en/about-us/security/psirt/e2025-09-25" } ], "source": { "discovery": "UNKNOWN" }, "title": "Ericsson Indoor Connect 8855 - Improper Neutralization of Special Elements used in an SQL Command Vulnerability", "x_generator": { "engine": "Vulnogram 0.2.0" } }, "adp": [ { "metrics": [ { "other": { "type": "ssvc", "content": { "timestamp": "2025-09-25T14:30:26.479892Z", "id": "CVE-2025-27261", "options": [ { "Exploitation": "none" }, { "Automatable": "no" }, { "Technical Impact": "total" } ], "role": "CISA Coordinator", "version": "2.0.3" } } } ], "title": "CISA ADP Vulnrichment", "providerMetadata": { "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "shortName": "CISA-ADP", "dateUpdated": "2025-09-25T14:30:40.991Z" } } ] } }