{ "dataType": "CVE_RECORD", "dataVersion": "5.2", "cveMetadata": { "cveId": "CVE-2025-2884", "assignerOrgId": "37e5125f-f79b-445b-8fad-9564f167944b", "state": "PUBLISHED", "assignerShortName": "certcc", "dateReserved": "2025-03-27T21:01:41.908Z", "datePublished": "2025-06-10T17:29:19.463Z", "dateUpdated": "2026-08-11T12:22:36.753Z" }, "containers": { "cna": { "title": "Out-of-Bounds read vulnerability in TCG TPM2.0 reference implementation", "descriptions": [ { "lang": "en", "value": "TCG TPM2.0 Reference implementation's CryptHmacSign helper function is vulnerable to Out-of-Bounds read due to the lack of validation the signature scheme with the signature key's algorithm. See Errata Revision 1.83 and advisory TCGVRT0009 for TCG standard TPM2.0" } ], "source": { "discovery": "INTERNAL" }, "affected": [ { "vendor": "Trusted Computing Group", "product": "TPM2.0", "versions": [ { "status": "affected", "version": "0", "lessThan": "1.83", "versionType": "custom" } ] } ], "problemTypes": [ { "descriptions": [ { "lang": "en", "description": "CWE-125 Out-of-bounds Read" } ] } ], "references": [ { "url": "https://trustedcomputinggroup.org/about/security/" }, { "url": "https://trustedcomputinggroup.org/wp-content/uploads/TPM2.0-Library-Spec-v1.83-Errata_v1_pub.pdf", "name": "TPM2.0 Errata" }, { "url": "https://trustedcomputinggroup.org/wp-content/uploads/VRT0009-Advisory-FINAL.pdf", "name": "Vendor Advisory" }, { "url": "https://github.com/stefanberger/libtpms/commit/04b2d8e9afc0a9b6bffe562a23e58c0de11532d1", "name": "Vendor Patch" }, { "url": "https://www.cve.org/CVERecord?id=CVE-2025-49133", "name": "Related CVE" } ], "x_generator": { "engine": "VINCE 3.0.20", "env": "prod", "origin": "https://cveawg.mitre.org/api/cve/CVE-2025-2884" }, "providerMetadata": { "orgId": "37e5125f-f79b-445b-8fad-9564f167944b", "shortName": "certcc", "dateUpdated": "2025-06-13T18:22:21.856Z" }, "metrics": [ { "other": { "type": "ssvcV1_0_1", "content": { "id": "CVE-2025-2884", "selections": [ { "namespace": "ssvc", "version": "1.0.0", "values": [ "none" ], "name": "Exploitation" }, { "namespace": "ssvc", "version": "2.0.0", "values": [ "no" ], "name": "Automatable" }, { "namespace": "ssvc", "version": "1.0.0", "values": [ "partial" ], "name": "Technical Impact" }, { "namespace": "ssvc", "version": "1.0.0", "values": [ "medium" ], "name": "Mission & Well-being" } ], "timestamp": "2025-06-13T17:22:30.584Z" } } } ] }, "adp": [ { "title": "CVE Program Container", "references": [ { "url": "https://www.intel.com/content/www/us/en/security-center/advisory/intel-sa-01209.html" }, { "url": "https://www.kb.cert.org/vuls/id/282450" } ], "providerMetadata": { "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE", "dateUpdated": "2025-06-10T19:02:29.811Z" } }, { "problemTypes": [ { "descriptions": [ { "type": "CWE", "cweId": "CWE-125", "lang": "en", "description": "CWE-125 Out-of-bounds Read" } ] } ], "metrics": [ { "cvssV3_1": { "scope": "UNCHANGED", "version": "3.1", "baseScore": 6.6, "attackVector": "LOCAL", "baseSeverity": "MEDIUM", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:R/S:U/C:H/I:N/A:H", "integrityImpact": "NONE", "userInteraction": "REQUIRED", "attackComplexity": "LOW", "availabilityImpact": "HIGH", "privilegesRequired": "LOW", "confidentialityImpact": "HIGH" } }, { "other": { "type": "ssvc", "content": { "timestamp": "2025-06-13T01:41:10.489446Z", "id": "CVE-2025-2884", "options": [ { "Exploitation": "none" }, { "Automatable": "no" }, { "Technical Impact": "partial" } ], "role": "CISA Coordinator", "version": "2.0.3" } } } ], "title": "CISA ADP Vulnrichment", "providerMetadata": { "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "shortName": "CISA-ADP", "dateUpdated": "2025-06-13T01:46:13.802Z" } }, { "x_adpType": "supplier", "providerMetadata": { "orgId": "0b142b55-0307-4c5a-b3c9-f314f3fb7c5e", "shortName": "siemens-SADP", "dateUpdated": "2026-08-11T12:22:36.753Z" }, "affected": [ { "vendor": "Siemens", "product": "SIMATIC CN 4100", "versions": [ { "status": "affected", "version": "0", "lessThan": "*", "versionType": "custom" } ], "defaultStatus": "unknown" }, { "vendor": "Siemens", "product": "SIMATIC Field PG M5", "versions": [ { "status": "affected", "version": "0", "lessThan": "*", "versionType": "custom" } ], "defaultStatus": "unknown" }, { "vendor": "Siemens", "product": "SIMATIC Field PG M6", "versions": [ { "status": "affected", "version": "0", "lessThan": "V26.01.14", "versionType": "custom" } ], "defaultStatus": "unknown" }, { "vendor": "Siemens", "product": "SIMATIC IPC BX-32A", "versions": [ { "status": "affected", "version": "0", "lessThan": "V29.01.09", "versionType": "custom" } ], "defaultStatus": "unknown" }, { "vendor": "Siemens", "product": "SIMATIC IPC BX-39A", "versions": [ { "status": "affected", "version": "0", "lessThan": "V29.01.09", "versionType": "custom" } ], "defaultStatus": "unknown" }, { "vendor": "Siemens", "product": "SIMATIC IPC BX-56A", "versions": [ { "status": "affected", "version": "0", "lessThan": "V32.01.09", "versionType": "custom" } ], "defaultStatus": "unknown" }, { "vendor": "Siemens", "product": "SIMATIC IPC BX-59A", "versions": [ { "status": "affected", "version": "0", "lessThan": "V32.01.09", "versionType": "custom" } ], "defaultStatus": "unknown" }, { "vendor": "Siemens", "product": "SIMATIC IPC MD-57A", "versions": [ { "status": "affected", "version": "0", "lessThan": "V30.01.10", "versionType": "custom" } ], "defaultStatus": "unknown" }, { "vendor": "Siemens", "product": "SIMATIC IPC PX-32A", "versions": [ { "status": "affected", "version": "0", "lessThan": "V29.01.09", "versionType": "custom" } ], "defaultStatus": "unknown" }, { "vendor": "Siemens", "product": "SIMATIC IPC PX-39A", "versions": [ { "status": "affected", "version": "0", "lessThan": "V29.01.09", "versionType": "custom" } ], "defaultStatus": "unknown" }, { "vendor": "Siemens", "product": "SIMATIC IPC PX-39A PRO", "versions": [ { "status": "affected", "version": "0", "lessThan": "V29.01.09", "versionType": "custom" } ], "defaultStatus": "unknown" }, { "vendor": "Siemens", "product": "SIMATIC IPC RW-528A", "versions": [ { "status": "affected", "version": "0", "lessThan": "V34.01.02", "versionType": "custom" } ], "defaultStatus": "unknown" }, { "vendor": "Siemens", "product": "SIMATIC IPC RW-548A", "versions": [ { "status": "affected", "version": "0", "lessThan": "V34.01.02", "versionType": "custom" } ], "defaultStatus": "unknown" }, { "vendor": "Siemens", "product": "SIMATIC IPC227E", "versions": [ { "status": "affected", "version": "0", "lessThan": "*", "versionType": "custom" } ], "defaultStatus": "unknown" }, { "vendor": "Siemens", "product": "SIMATIC IPC277E", "versions": [ { "status": "affected", "version": "0", "lessThan": "*", "versionType": "custom" } ], "defaultStatus": "unknown" }, { "vendor": "Siemens", "product": "SIMATIC IPC427E", "versions": [ { "status": "affected", "version": "0", "lessThan": "V21.01.20", "versionType": "custom" } ], "defaultStatus": "unknown" }, { "vendor": "Siemens", "product": "SIMATIC IPC477E", "versions": [ { "status": "affected", "version": "0", "lessThan": "V21.01.20", "versionType": "custom" } ], "defaultStatus": "unknown" }, { "vendor": "Siemens", "product": "SIMATIC IPC477E PRO", "versions": [ { "status": "affected", "version": "0", "lessThan": "V21.01.20", "versionType": "custom" } ], "defaultStatus": "unknown" }, { "vendor": "Siemens", "product": "SIMATIC IPC627E", "versions": [ { "status": "affected", "version": "0", "lessThan": "*", "versionType": "custom" } ], "defaultStatus": "unknown" }, { "vendor": "Siemens", "product": "SIMATIC IPC647E", "versions": [ { "status": "affected", "version": "0", "lessThan": "*", "versionType": "custom" } ], "defaultStatus": "unknown" }, { "vendor": "Siemens", "product": "SIMATIC IPC677E", "versions": [ { "status": "affected", "version": "0", "lessThan": "*", "versionType": "custom" } ], "defaultStatus": "unknown" }, { "vendor": "Siemens", "product": "SIMATIC IPC847E", "versions": [ { "status": "affected", "version": "0", "lessThan": "*", "versionType": "custom" } ], "defaultStatus": "unknown" }, { "vendor": "Siemens", "product": "SIMATIC ITP1000", "versions": [ { "status": "affected", "version": "0", "lessThan": "*", "versionType": "custom" } ], "defaultStatus": "unknown" }, { "vendor": "Siemens", "product": "SIPLUS IPC427E", "versions": [ { "status": "affected", "version": "0", "lessThan": "V21.01.20", "versionType": "custom" } ], "defaultStatus": "unknown" } ], "references": [ { "url": "https://cert-portal.siemens.com/productcert/html/ssa-628843.html" } ] } ] } }