{ "dataType": "CVE_RECORD", "dataVersion": "5.1", "cveMetadata": { "cveId": "CVE-2025-30519", "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6", "state": "PUBLISHED", "assignerShortName": "icscert", "dateReserved": "2025-08-18T15:32:05.607Z", "datePublished": "2025-09-18T20:46:42.642Z", "dateUpdated": "2025-09-19T13:05:20.889Z" }, "containers": { "cna": { "affected": [ { "defaultStatus": "unaffected", "product": "ProGauge MagLink LX 4", "vendor": "Dover Fueling Solutions", "versions": [ { "lessThan": "4.20.3", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unaffected", "product": "ProGauge MagLink LX Plus", "vendor": "Dover Fueling Solutions", "versions": [ { "lessThan": "4.20.3", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unaffected", "product": "ProGauge MagLink LX Ultimate", "vendor": "Dover Fueling Solutions", "versions": [ { "lessThan": "5.20.3", "status": "affected", "version": "0", "versionType": "custom" } ] } ], "credits": [ { "lang": "en", "type": "finder", "value": "Pedro Umbelino of Bitsight TRACE reported these vulnerabilities to CISA." } ], "descriptions": [ { "lang": "en", "supportingMedia": [ { "base64": false, "type": "text/html", "value": "Dover Fueling Solutions ProGauge MagLink LX4 Devices have default root credentials that cannot be changed through standard \nadministrative means. An attacker with network access to the device can \ngain administrative access to the system." } ], "value": "Dover Fueling Solutions ProGauge MagLink LX4 Devices have default root credentials that cannot be changed through standard \nadministrative means. An attacker with network access to the device can \ngain administrative access to the system." } ], "metrics": [ { "cvssV3_1": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 9.8, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, "format": "CVSS", "scenarios": [ { "lang": "en", "value": "GENERAL" } ] }, { "cvssV4_0": { "Automatable": "NOT_DEFINED", "Recovery": "NOT_DEFINED", "Safety": "NOT_DEFINED", "attackComplexity": "LOW", "attackRequirements": "NONE", "attackVector": "NETWORK", "baseScore": 9.3, "baseSeverity": "CRITICAL", "privilegesRequired": "NONE", "providerUrgency": "NOT_DEFINED", "subAvailabilityImpact": "NONE", "subConfidentialityImpact": "NONE", "subIntegrityImpact": "NONE", "userInteraction": "NONE", "valueDensity": "NOT_DEFINED", "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N", "version": "4.0", "vulnAvailabilityImpact": "HIGH", "vulnConfidentialityImpact": "HIGH", "vulnIntegrityImpact": "HIGH", "vulnerabilityResponseEffort": "NOT_DEFINED" }, "format": "CVSS", "scenarios": [ { "lang": "en", "value": "GENERAL" } ] } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-1391", "description": "CWE-1391", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6", "shortName": "icscert", "dateUpdated": "2025-09-18T20:46:42.642Z" }, "references": [ { "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-25-261-07" }, { "url": "https://www.doverfuelingsolutions.com/mea/en/products-and-solutions/automatic-tank-gauging/consoles/progauge-maglink-lx-4-console.html" } ], "solutions": [ { "lang": "en", "supportingMedia": [ { "base64": false, "type": "text/html", "value": "Dover Fueling Solutions recommends users update their ProGauge MagLink \ndevices to Version 4.20.3 or later for MagLink LX 4 and MagLink LX Plus \nmodels. The upgrade can be downloaded from the Dover Fueling Solutions website .
For MagLink LX Ultimate devices, Dover Fueling Solutions recommends users update to version 5.20.3 or later.
\nDover Fueling Solutions recommends all users install the software behind a firewall to minimize risk of remote attacks.
\n\n