{ "dataType": "CVE_RECORD", "dataVersion": "5.2", "cveMetadata": { "cveId": "CVE-2025-34215", "assignerOrgId": "83251b91-4cc7-4094-a5c7-464a1b83ea10", "state": "PUBLISHED", "assignerShortName": "VulnCheck", "dateReserved": "2025-04-15T19:15:22.572Z", "datePublished": "2025-09-29T20:43:12.104Z", "dateUpdated": "2026-05-15T11:15:24.734Z" }, "containers": { "cna": { "affected": [ { "defaultStatus": "unaffected", "modules": [ "/admin/design/management_accountts_pcabout.php", "/va‑api/v1/update", "private key embedded in the appliance" ], "product": "Print Virtual Appliance Host", "vendor": "Vasion", "versions": [ { "lessThan": "22.0.1026", "status": "affected", "version": "0", "versionType": "semver" } ] }, { "defaultStatus": "unaffected", "modules": [ "/admin/design/management_accountts_pcabout.php", "/va‑api/v1/update", "private key embedded in the appliance" ], "product": "Print Application", "vendor": "Vasion", "versions": [ { "lessThan": "20.0.2702", "status": "affected", "version": "0", "versionType": "semver" } ] } ], "cpeApplicability": [ { "operator": "OR", "nodes": [ { "operator": "OR", "negate": false, "cpeMatch": [ { "vulnerable": true, "criteria": "cpe:2.3:a:vasion:virtual_appliance_host:*:*:*:*:*:*:*:*", "versionEndExcluding": "22.0.1026" } ] } ] }, { "operator": "OR", "nodes": [ { "operator": "OR", "negate": false, "cpeMatch": [ { "vulnerable": true, "criteria": "cpe:2.3:a:vasion:virtual_appliance_application:*:*:*:*:*:*:*:*", "versionEndExcluding": "20.0.2702" } ] } ] } ], "credits": [ { "lang": "en", "type": "finder", "value": "Pierre Barre" } ], "descriptions": [ { "lang": "en", "supportingMedia": [ { "base64": false, "type": "text/html", "value": "Vasion Print (formerly PrinterLogic) Virtual Appliance Host prior to version 22.0.1026 and Application prior to version 20.0.2702 (only VA deployments) expose an unauthenticated firmware-upload flow: a public page returns a signed token usable at va-api/v1/update, and every Docker image contains the appliance’s private GPG key and hard-coded passphrase. An attacker who extracts the key and obtains a token can decrypt, modify, re-sign, upload, and trigger malicious firmware, gaining remote code execution. This vulnerability has been identified by the vendor as: V-2024-020 — Remote Code Execution.
" } ], "value": "Vasion Print (formerly PrinterLogic) Virtual Appliance Host prior to version 22.0.1026 and Application prior to version 20.0.2702 (only VA deployments) expose an unauthenticated firmware-upload flow: a public page returns a signed token usable at va-api/v1/update, and every Docker image contains the appliance’s private GPG key and hard-coded passphrase. An attacker who extracts the key and obtains a token can decrypt, modify, re-sign, upload, and trigger malicious firmware, gaining remote code execution. This vulnerability has been identified by the vendor as: V-2024-020 — Remote Code Execution." } ], "impacts": [ { "capecId": "CAPEC-115", "descriptions": [ { "lang": "en", "value": "CAPEC-115 Authentication Bypass" } ] }, { "capecId": "CAPEC-186", "descriptions": [ { "lang": "en", "value": "CAPEC-186 Malicious Software Update" } ] } ], "metrics": [ { "cvssV4_0": { "Automatable": "NOT_DEFINED", "Recovery": "NOT_DEFINED", "Safety": "NOT_DEFINED", "attackComplexity": "LOW", "attackRequirements": "NONE", "attackVector": "NETWORK", "baseScore": 9.4, "baseSeverity": "CRITICAL", "exploitMaturity": "NOT_DEFINED", "privilegesRequired": "HIGH", "providerUrgency": "NOT_DEFINED", "subAvailabilityImpact": "HIGH", "subConfidentialityImpact": "HIGH", "subIntegrityImpact": "HIGH", "userInteraction": "NONE", "valueDensity": "NOT_DEFINED", "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:H/UI:N/VC:H/VI:H/VA:H/SC:H/SI:H/SA:H", "version": "4.0", "vulnAvailabilityImpact": "HIGH", "vulnConfidentialityImpact": "HIGH", "vulnIntegrityImpact": "HIGH", "vulnerabilityResponseEffort": "NOT_DEFINED" }, "format": "CVSS", "scenarios": [ { "lang": "en", "value": "GENERAL" } ] } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-306", "description": "CWE-306 Missing Authentication for Critical Function", "lang": "en", "type": "CWE" } ] }, { "descriptions": [ { "cweId": "CWE-321", "description": "CWE-321 Use of Hard-coded Cryptographic Key", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "orgId": "83251b91-4cc7-4094-a5c7-464a1b83ea10", "shortName": "VulnCheck", "dateUpdated": "2026-05-15T11:15:24.734Z" }, "references": [ { "tags": [ "technical-description" ], "url": "https://pierrekim.github.io/blog/2025-04-08-vasion-printerlogic-83-vulnerabilities.html#va-rce-02" }, { "tags": [ "vendor-advisory", "patch" ], "url": "https://help.printerlogic.com/va/Print/Security/Security-Bulletins.htm" }, { "tags": [ "vendor-advisory", "patch" ], "url": "https://help.printerlogic.com/saas/Print/Security/Security-Bulletins.htm" }, { "tags": [ "third-party-advisory" ], "url": "https://www.vulncheck.com/advisories/vasion-print-printerlogic-unauth-firmware-update-endpoint-rce" } ], "source": { "discovery": "INTERNAL" }, "title": "Vasion Print (formerly PrinterLogic) Unauthenticated Firmware Update Endpoint RCE", "x_generator": { "engine": "vulncheck" } }, "adp": [ { "references": [ { "url": "https://pierrekim.github.io/blog/2025-04-08-vasion-printerlogic-83-vulnerabilities.html#va-rce-02", "tags": [ "exploit" ] } ], "metrics": [ { "other": { "type": "ssvc", "content": { "timestamp": "2025-09-30T15:13:51.289719Z", "id": "CVE-2025-34215", "options": [ { "Exploitation": "poc" }, { "Automatable": "no" }, { "Technical Impact": "total" } ], "role": "CISA Coordinator", "version": "2.0.3" } } } ], "title": "CISA ADP Vulnrichment", "providerMetadata": { "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "shortName": "CISA-ADP", "dateUpdated": "2025-09-30T15:19:34.437Z" } } ] } }