{ "dataType": "CVE_RECORD", "dataVersion": "5.2", "cveMetadata": { "cveId": "CVE-2025-36751", "assignerOrgId": "b87402ff-ae37-4194-9dae-31abdbd6f217", "state": "PUBLISHED", "assignerShortName": "DIVD", "dateReserved": "2025-04-15T21:54:36.814Z", "datePublished": "2025-12-13T08:16:21.309Z", "dateUpdated": "2025-12-16T11:02:09.858Z" }, "containers": { "cna": { "affected": [ { "defaultStatus": "unaffected", "product": "ShineLan-X", "vendor": "Growatt", "versions": [ { "lessThanOrEqual": "3.6.0.2", "status": "affected", "version": "3.6.0.0", "versionType": "semver" } ] } ], "credits": [ { "lang": "en", "type": "finder", "value": "Alexandros Tokatlis" }, { "lang": "en", "type": "analyst", "value": "Victor Pasman" } ], "descriptions": [ { "lang": "en", "supportingMedia": [ { "base64": false, "type": "text/html", "value": "Encryption is missing on the configuration interface for Growatt ShineLan-X and MIC 3300TL-X. This allows an attacker with access to the network to intercept and potentially manipulate communication requests between the inverter and its cloud endpoint." } ], "value": "Encryption is missing on the configuration interface for Growatt ShineLan-X and MIC 3300TL-X. This allows an attacker with access to the network to intercept and potentially manipulate communication requests between the inverter and its cloud endpoint." } ], "impacts": [ { "capecId": "CAPEC-176", "descriptions": [ { "lang": "en", "value": "CAPEC-176 Configuration/Environment Manipulation" } ] } ], "metrics": [ { "cvssV4_0": { "Automatable": "NOT_DEFINED", "Recovery": "NOT_DEFINED", "Safety": "PRESENT", "attackComplexity": "LOW", "attackRequirements": "NONE", "attackVector": "ADJACENT", "baseScore": 9.4, "baseSeverity": "CRITICAL", "privilegesRequired": "NONE", "providerUrgency": "NOT_DEFINED", "subAvailabilityImpact": "HIGH", "subConfidentialityImpact": "HIGH", "subIntegrityImpact": "HIGH", "userInteraction": "NONE", "valueDensity": "NOT_DEFINED", "vectorString": "CVSS:4.0/AV:A/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:H/SI:H/SA:H", "version": "4.0", "vulnAvailabilityImpact": "HIGH", "vulnConfidentialityImpact": "HIGH", "vulnIntegrityImpact": "HIGH", "vulnerabilityResponseEffort": "NOT_DEFINED" }, "format": "CVSS", "scenarios": [ { "lang": "en", "value": "GENERAL" } ] } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-311", "description": "CWE-311 Missing Encryption of Sensitive Data", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "orgId": "b87402ff-ae37-4194-9dae-31abdbd6f217", "shortName": "DIVD", "dateUpdated": "2025-12-16T11:02:09.858Z" }, "references": [ { "tags": [ "third-party-advisory" ], "url": "https://csirt.divd.nl/CVE-2025-36751/" } ], "source": { "discovery": "EXTERNAL" }, "title": "Missing encryption on Local Configuration Interface or Cloud Endpoint Communication - Growatt MIC3300TL-X and ShineLan-X", "x_generator": { "engine": "Vulnogram 0.2.0" } }, "adp": [ { "metrics": [ { "other": { "type": "ssvc", "content": { "timestamp": "2025-12-15T20:30:12.399256Z", "id": "CVE-2025-36751", "options": [ { "Exploitation": "none" }, { "Automatable": "no" }, { "Technical Impact": "total" } ], "role": "CISA Coordinator", "version": "2.0.3" } } } ], "title": "CISA ADP Vulnrichment", "providerMetadata": { "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "shortName": "CISA-ADP", "dateUpdated": "2025-12-15T20:33:42.102Z" } } ] } }