{ "dataType": "CVE_RECORD", "dataVersion": "5.2", "cveMetadata": { "cveId": "CVE-2025-40800", "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77", "state": "PUBLISHED", "assignerShortName": "siemens", "dateReserved": "2025-04-16T08:50:26.973Z", "datePublished": "2025-12-09T10:44:23.488Z", "dateUpdated": "2026-03-10T16:07:47.742Z" }, "containers": { "cna": { "providerMetadata": { "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77", "shortName": "siemens", "dateUpdated": "2026-03-10T16:07:47.742Z" }, "descriptions": [ { "lang": "en", "value": "A vulnerability has been identified in COMOS V10.6 (All versions < V10.6.1), COMOS V10.6 (All versions < V10.6.1), NX V2412 (All versions < V2412.8700), NX V2506 (All versions < V2506.6000), Simcenter 3D (All versions < V2506.6000), Simcenter Femap (All versions < V2506.0002), Solid Edge SE2025 (All versions < V225.0 Update 10), Solid Edge SE2026 (All versions < V226.0 Update 1). The IAM client in affected products is missing server certificate validation while establishing TLS connections to the authorization server. This could allow an attacker to perform a man-in-the-middle attack." } ], "affected": [ { "vendor": "Siemens", "product": "COMOS V10.6", "versions": [ { "status": "affected", "version": "0", "lessThan": "V10.6.1", "versionType": "custom" } ], "defaultStatus": "unknown" }, { "vendor": "Siemens", "product": "COMOS V10.6", "versions": [ { "status": "affected", "version": "0", "lessThan": "V10.6.1", "versionType": "custom" } ], "defaultStatus": "unknown" }, { "vendor": "Siemens", "product": "NX V2412", "versions": [ { "status": "affected", "version": "0", "lessThan": "V2412.8700", "versionType": "custom" } ], "defaultStatus": "unknown" }, { "vendor": "Siemens", "product": "NX V2506", "versions": [ { "status": "affected", "version": "0", "lessThan": "V2506.6000", "versionType": "custom" } ], "defaultStatus": "unknown" }, { "vendor": "Siemens", "product": "Simcenter 3D", "versions": [ { "status": "affected", "version": "0", "lessThan": "V2506.6000", "versionType": "custom" } ], "defaultStatus": "unknown" }, { "vendor": "Siemens", "product": "Simcenter Femap", "versions": [ { "status": "affected", "version": "0", "lessThan": "V2506.0002", "versionType": "custom" } ], "defaultStatus": "unknown" }, { "vendor": "Siemens", "product": "Solid Edge SE2025", "versions": [ { "status": "affected", "version": "0", "lessThan": "V225.0 Update 10", "versionType": "custom" } ], "defaultStatus": "unknown" }, { "vendor": "Siemens", "product": "Solid Edge SE2026", "versions": [ { "status": "affected", "version": "0", "lessThan": "V226.0 Update 1", "versionType": "custom" } ], "defaultStatus": "unknown" } ], "metrics": [ { "cvssV3_1": { "version": "3.1", "vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:H/I:H/A:N", "baseScore": 7.4, "baseSeverity": "HIGH" } }, { "cvssV4_0": { "version": "4.0", "vectorString": "CVSS:4.0/AV:N/AC:L/AT:P/PR:N/UI:N/VC:H/VI:H/VA:N/SC:N/SI:N/SA:N", "baseScore": 9.1, "baseSeverity": "CRITICAL" } } ], "problemTypes": [ { "descriptions": [ { "lang": "en", "cweId": "CWE-295", "description": "CWE-295: Improper Certificate Validation", "type": "CWE" } ] } ], "references": [ { "url": "https://cert-portal.siemens.com/productcert/html/ssa-868571.html" }, { "url": "https://cert-portal.siemens.com/productcert/html/ssa-212953.html" } ] }, "adp": [ { "metrics": [ { "other": { "type": "ssvc", "content": { "timestamp": "2025-12-09T14:27:11.176631Z", "id": "CVE-2025-40800", "options": [ { "Exploitation": "none" }, { "Automatable": "no" }, { "Technical Impact": "total" } ], "role": "CISA Coordinator", "version": "2.0.3" } } } ], "title": "CISA ADP Vulnrichment", "providerMetadata": { "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "shortName": "CISA-ADP", "dateUpdated": "2025-12-09T14:27:15.289Z" } } ] } }