{ "dataType": "CVE_RECORD", "dataVersion": "5.1", "cveMetadata": { "cveId": "CVE-2025-4041", "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6", "state": "PUBLISHED", "assignerShortName": "icscert", "dateReserved": "2025-04-28T14:39:33.460Z", "datePublished": "2025-05-06T16:35:18.133Z", "dateUpdated": "2025-05-06T17:29:11.988Z" }, "containers": { "cna": { "affected": [ { "defaultStatus": "unaffected", "product": "ONS NC600", "vendor": "Optigo Networks", "versions": [ { "lessThanOrEqual": "4.7.2-330", "status": "affected", "version": "4.2.1-084", "versionType": "custom" } ] } ], "credits": [ { "lang": "en", "type": "finder", "value": "Tomer Goldschmidt of Claroty Team82" } ], "descriptions": [ { "lang": "en", "supportingMedia": [ { "base64": false, "type": "text/html", "value": "
In Optigo Networks ONS NC600 versions 4.2.1-084 through 4.7.2-330, an attacker could connect with the device's ssh server and utilize the system's components to perform OS command executions.
" } ], "value": "In Optigo Networks ONS NC600 versions 4.2.1-084 through 4.7.2-330, an attacker could connect with the device's ssh server and utilize the system's components to perform OS command executions." } ], "metrics": [ { "cvssV4_0": { "Automatable": "NOT_DEFINED", "Recovery": "NOT_DEFINED", "Safety": "NOT_DEFINED", "attackComplexity": "LOW", "attackRequirements": "NONE", "attackVector": "NETWORK", "baseScore": 9.3, "baseSeverity": "CRITICAL", "privilegesRequired": "NONE", "providerUrgency": "NOT_DEFINED", "subAvailabilityImpact": "NONE", "subConfidentialityImpact": "NONE", "subIntegrityImpact": "NONE", "userInteraction": "NONE", "valueDensity": "NOT_DEFINED", "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N", "version": "4.0", "vulnAvailabilityImpact": "HIGH", "vulnConfidentialityImpact": "HIGH", "vulnIntegrityImpact": "HIGH", "vulnerabilityResponseEffort": "NOT_DEFINED" }, "format": "CVSS", "scenarios": [ { "lang": "en", "value": "GENERAL" } ] } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-798", "description": "CWE-798 Use of Hard-coded Credentials", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6", "shortName": "icscert", "dateUpdated": "2025-05-06T16:35:18.133Z" }, "references": [ { "tags": [ "government-resource" ], "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-25-126-01" } ], "solutions": [ { "lang": "en", "supportingMedia": [ { "base64": false, "type": "text/html", "value": "Optigo Networks recommends users implement at least one of the following additional mitigations: